2,637 research outputs found

    On active region loops: Hinode/EIS observations

    Full text link
    Coronal loops are fundamental building blocks of the solar active regions and the corona. Therefore, a clear understanding of the physics of coronal loops will help us understand the physics of active region heating in particular and coronal heating in general. This requires a precise measurement of physical quantities such as electron densities and filling factors, temperatures, and flows in coronal loops. In this paper we have carried out an investigation of a spatially well resolved coronal loop using the EIS onboard Hinode to measure the above mentioned physical quantities. Based on this study we find that a nano-flare model could explain most of the observed characteristics of this loop.Comment: 27 pages, 7 figures, Accepted in Ap

    Aging in One-Dimensional Coagulation-Diffusion Processes and the Fredrickson-Andersen Model

    Full text link
    We analyse the aging dynamics of the one-dimensional Fredrickson-Andersen (FA) model in the nonequilibrium regime following a low temperature quench. Relaxation then effectively proceeds via diffusion limited pair coagulation (DLPC) of mobility excitations. By employing a familiar stochastic similarity transformation, we map exact results from the free fermion case of diffusion limited pair annihilation to DLPC. Crucially, we are able to adapt the mapping technique to averages involving multiple time quantities. This relies on knowledge of the explicit form of the evolution operators involved. Exact results are obtained for two-time correlation and response functions in the free fermion DLPC process. The corresponding long-time scaling forms apply to a wider class of DLPC processes, including the FA model. We are thus able to exactly characterise the violations of the fluctuation-dissipation theorem (FDT) in the aging regime of the FA model. We find nontrivial scaling forms for the fluctuation-dissipation ratio (FDR) X = X(tw/t), but with a negative asymptotic value X = -3*pi/(6*pi - 16) = -3.307. While this prevents a thermodynamic interpretation in terms of an effective temperature, it is a direct consequence of probing FDT with observables that couple to activated dynamics. The existence of negative FDRs should therefore be a widespread feature in non mean-field systems.Comment: 39 pages, 4 figure

    Pioglitazone for secondary prevention after ischemic stroke and transient ischemic attack: Rationale and design of the Insulin Resistance Intervention after Stroke Trial

    Get PDF
    Background: Recurrent vascular events remain a major source of morbidity and mortality after stroke or transient ischemic attack (TIA). The IRIS Trial is evaluating an approach to secondary prevention based on the established association between insulin resistance and increased risk for ischemic vascular events. Specifically, IRIS will test the effectiveness of pioglitazone, an insulin-sensitizing drug of the thiazolidinedione class, for reducing the risk for stroke and myocardial infarction (MI) among insulin resistant, nondiabetic patients with a recent ischemic stroke or TIA. Design: Eligible patients for IRIS must have had insulin resistance defined by a Homeostasis Model Assessment-Insulin Resistance \u3e3.0 without meeting criteria for diabetes. Within 6 months of the index stroke or TIA, patients were randomly assigned to pioglitazone (titrated from 15 to 45 mg/d) or matching placebo and followed for up to 5 years. The primary outcome is time to stroke or MI. Secondary outcomes include time to stroke alone, acute coronary syndrome, diabetes, cognitive decline, and all-cause mortality. Enrollment of 3,876 participants from 179 sites in 7 countries was completed in January 2013. Participant follow-up will continue until July 2015. Summary: The IRIS Trial will determine whether treatment with pioglitazone improves cardiovascular outcomes of nondiabetic, insulin-resistant patients with stroke or TIA. Results are expected in early 2016

    Non-equilibrium dynamics of spin facilitated glass models

    Full text link
    We consider the dynamics of spin facilitated models of glasses in the non-equilibrium aging regime following a sudden quench from high to low temperatures. We briefly review known results obtained for the broad class of kinetically constrained models, and then present new results for the behaviour of the one-spin facilitated Fredrickson-Andersen and East models in various spatial dimensions. The time evolution of one-time quantities, such as the energy density, and the detailed properties of two-time correlation and response functions are studied using a combination of theoretical approaches, including exact mappings of master operators and reductions to integrable quantum spin chains, field theory and renormalization group, and independent interval and timescale separation methods. The resulting analytical predictions are confirmed by means of detailed numerical simulations. The models we consider are characterized by trivial static properties, with no finite temperature singularities, but they nevertheless display a surprising variety of dynamic behaviour during aging, which can be directly related to the existence and growth in time of dynamic lengthscales. Well-behaved fluctuation-dissipation ratios can be defined for these models, and we study their properties in detail. We confirm in particular the existence of negative fluctuation-dissipation ratios for a large number of observables. Our results suggest that well-defined violations of fluctuation-dissipation relations, of a purely dynamic origin and unrelated to the thermodynamic concept of effective temperatures, could in general be present in non-equilibrium glassy materials.Comment: 72 pages, invited contribution to special issue of JSTAT on "Principles of Dynamics of Nonequilibrium Systems" (Programme at Newton Institute Cambridge). v2: New data added to Figs. 11, 23, 24, new Fig. 26 on East model in d=3, minor improvements to tex

    Improving the performance of bright quantum dot single photon sources using amplitude modulation

    Get PDF
    Single epitaxially-grown semiconductor quantum dots have great potential as single photon sources for photonic quantum technologies, though in practice devices often exhibit non-ideal behavior. Here, we demonstrate that amplitude modulation can improve the performance of quantum-dot-based sources. Starting with a bright source consisting of a single quantum dot in a fiber-coupled microdisk cavity, we use synchronized amplitude modulation to temporally filter the emitted light. We observe that the single photon purity, temporal overlap between successive emission events, and indistinguishability can be greatly improved with this technique. As this method can be applied to any triggered single photon source, independent of geometry and after device fabrication, it is a flexible approach to improve the performance of solid-state systems, which often suffer from excess dephasing and multi-photon background emission

    Cognitive Information Processing

    Get PDF
    Contains reports on seven research projects.National Science Foundation (Grant SED76-81985)Graphic Arts Research Foundation (Grant)Providence Gravure, Inc. (Grant)Associated Press (Grant)National Institutes of Health (Grant 1 RO1 GM22547-01)National Institutes of Health (Grant 1 PO1 AG00354-01)Health Sciences Fund (Grant 76-11

    The incidence of ventilator-associated pneumonia using the PneuX System with or without elective endotracheal tube exchange: A pilot study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The PneuX System is a novel endotracheal tube and tracheal seal monitor, which has been designed to minimise the aspiration of oropharyngeal secretions. We aimed to determine the incidence of ventilator-associated pneumonia (VAP) in patients who were intubated with the PneuX System and to establish whether intermittent subglottic secretion drainage could be performed reliably and safely using the PneuX System.</p> <p>Findings</p> <p>In this retrospective observational study, data was collected from 53 sequential patients. Nine (17%) patients were initially intubated with the PneuX System and 44 (83%) patients underwent elective exchange to the PneuX System. There were no episodes of VAP while the PneuX System was <it>in situ</it>. On an intention to treat basis, the incidence VAP was 1.8%. There were no complications from, or failure of, subglottic secretion drainage during the study.</p> <p>Conclusions</p> <p>Our study demonstrates that a low incidence of VAP is possible using the PneuX System. Our study also demonstrates that elective exchange and intermittent subglottic secretion drainage can be performed reliably and safely using the PneuX System.</p

    Relationship Between Non-Hodgkin's Lymphoma and Blood Levels of Epstein-Barr Virus in Children in North-Western Tanzania: A Case Control Study.

    Get PDF
    Non-Hodgkin's Lymphomas (NHL) are common in African children, with endemic Burkitt's lymphoma (BL) being the most common subtype. While the role of Epstein-Barr Virus (EBV) in endemic BL is known, no data are available about clinical presentations of NHL subtypes and their relationship to Human Immunodeficiency Virus (HIV) infection and Epstein Barr Virus (EBV) load in peripheral blood of children in north-western, Tanzania. A matched case control study of NHL subtypes was performed in children under 15 years of age and their respective controls admitted to Bugando Medical Centre, Sengerema and Shirati district designated hospitals in north-western, Tanzania, between September 2010 and April 2011. Peripheral blood samples were collected on Whatman 903 filter papers and EBV DNA levels were estimated by multiplex real-time PCR. Clinical and laboratory data were collected using a structured data collection tool and analysed using chi-square, Fisher and Wilcoxon rank sum tests where appropriate. The association between NHL and detection of EBV in peripheral blood was assessed using conditional logistic regression model and presented as odds ratios (OR) and 95% confidence intervals (CI). A total of 35 NHL cases and 70 controls matched for age and sex were enrolled. Of NHLs, 32 had BL with equal distribution between jaw and abdominal tumour, 2 had large B cell lymphoma (DLBCL) and 1 had NHL-not otherwise specified (NHL-NOS). Central nervous system (CNS) presentation occurred only in 1 BL patient; 19 NHLs had stage I and II of disease. Only 1 NHL was found to be HIV-seropositive. Twenty-one of 35 (60%) NHL and 21 of 70 (30%) controls had detectable EBV in peripheral blood (OR = 4.77, 95% CI 1.71 - 13.33, p = 0.003). In addition, levels of EBV in blood were significantly higher in NHL cases than in controls (p = 0.024). BL is the most common childhood NHL subtype in north-western Tanzania. NHLs are not associated with HIV infection, but are strongly associated with EBV load in peripheral blood. The findings suggest that high levels of EBV in blood might have diagnostic and prognostic relevance in African children

    Feedhorn-coupled TES polarimeter camera modules at 150 GHz for CMB polarization measurements with SPTpol

    Full text link
    The SPTpol camera is a dichroic polarimetric receiver at 90 and 150 GHz. Deployed in January 2012 on the South Pole Telescope (SPT), SPTpol is looking for faint polarization signals in the Cosmic Microwave Background (CMB). The camera consists of 180 individual Transition Edge Sensor (TES) polarimeters at 90 GHz and seven 84-polarimeter camera modules (a total of 588 polarimeters) at 150 GHz. We present the design, dark characterization, and in-lab optical properties of the 150 GHz camera modules. The modules consist of photolithographed arrays of TES polarimeters coupled to silicon platelet arrays of corrugated feedhorns, both of which are fabricated at NIST-Boulder. In addition to mounting hardware and RF shielding, each module also contains a set of passive readout electronics for digital frequency-domain multiplexing. A single module, therefore, is fully functional as a miniature focal plane and can be tested independently. Across the modules tested before deployment, the detectors average a critical temperature of 478 mK, normal resistance R_N of 1.2 Ohm, unloaded saturation power of 22.5 pW, (detector-only) optical efficiency of ~ 90%, and have electrothermal time constants < 1 ms in transition.Comment: 15 pages, 11 figure
    • …
    corecore