594 research outputs found

    High-resolution extreme ultraviolet spectroscopy of G191-B2B: structure of the stellar photosphere and the surrounding interstellar medium

    Get PDF
    We have continued our detailed analysis of the high-resolution (R= 4000) spectroscopic observation of the DA white dwarf G191-B2B, obtained by the Joint Astrophysical Plasmadynamic Experiment (J-PEX) normal incidence sounding rocket-borne telescope, comparing the observed data with theoretical predictions for both homogeneous and stratified atmosphere structures. We find that the former models give the best agreement over the narrow waveband covered by J-PEX, in conflict with what is expected from previous studies of the lower resolution but broader wavelength coverage Extreme Ultraviolet Explorer spectra. We discuss the possible limitations of the atomic data and our understanding of the stellar atmospheres that might give rise to this inconsistency. In our earlier study, we obtained an unusually high ionization fraction for the ionized He ii present along the line of sight to the star. In the present paper, we obtain a better fit when we assume, as suggested by Space Telescope Imaging Spectrograph results, that this He ii resides in two separate components. When one of these is assigned to the local interstellar cloud, the implied He ionization fraction is consistent with measurements along other lines of sight. However, the resolving power and signal-to-noise available from the instrument configuration used in this first successful J-PEX flight are not sufficient to clearly identify and prove the existence of the two components

    A first step in determining appropriate amounts of obstetric anesthesia work

    Get PDF

    USA and RXTE Observations of a Variable Low-Frequency QPO in XTE J1118+480

    Get PDF
    The USA experiment on ARGOS and RXTE have exensively observed the X-ray transient XTE J1118+480 during its recent outburst in 2000 April--June. We present detailed monitoring of the evolution of a low frequency QPO which drifts from 0.07 Hz to 0.15 Hz during the outburst. We examine possible correlations of the QPO frequency with the flux and spectral characteristics of the source, and compare this QPO to low frequency QPOs observed in other black hole candidates.Comment: Accepted by ApJ Letters, reference added, minor revisions, 6 page

    Musculoskeletal aches and pains reported by labour ward staff

    Get PDF
    Awkward body postures and the progressive accumulation of muscle fatigue are known risk factors for the development of injury, with most work-related musculoskeletal disorders developing over time [1]. Work-related disorders can develop while carrying out normal physical work activities and are associated with fixed or constrained body positions and continual repetition of movements [1]. Heavy workloads on the maternity unit often require staff to perform physically demanding activities under pressure and adopt suboptimal postures. Simple ergonomic intervention such as providing suitable adjustable seating and the appropriate layout of equipment can reduce injuries, reduce sickness absence and improve productivity [2]

    USA Observation of Spectral and Timing Evolution During the 2000 Outburst of XTE J1550-564

    Get PDF
    We report on timing and spectral observations of the 2000 outburst of XTE J1550-564 made by the Unconventional Stellar Aspect (USA) Experiment on board the Advanced Research and Global Observation Satellite (ARGOS). We observe a low-frequency quasi-periodic oscillation (LFQPO) with a centroid frequency that tends to increase with increasing flux and a fractional rms amplitude which is correlated with the hardness ratio. The evolution of the hardness ratio (4--16 keV/1--4 keV) with time and source flux is examined. The hardness-intensity diagram (HID) shows a cyclical movement in the clockwise direction and possibly indicates the presence of two independent accretion flows. We observe a relationship between the USA 4--16 keV count rate and radio observations and discuss this in the context of previously observed correlations between X-ray, radio, optical and IR data. We examine our results in the context of models invoking two accretion flows: a thin disk and a hot sub-Keplerian flow.Comment: 11 pages, 2 figure

    Lack of a Hyperkalemic Response in Emergency Department Patients Receiving Succinylcholine

    Full text link
    Objective: To determine whether serum potassium (K) levels increase significantly following succinylcholine (SCh)-assisted intubation in ED patients. Methods: A prospective. noncontrolled, consecutive case series design was used to evaluate the change in serum K levels in ED patients who received SCh for emergency intubation. The study was performed at an academic medical center staffed by board-certified emergency physicians. The subjects were 100 consecutive prescreened ED patients with various diagnoses who received SCh for intubation. The eligible subjects had serum K levels determined prior to and 5 minutes after administration of a 1.0–1.5-mg/kg IV dose of SCh. Serum K levels were measured by the ionselective electrode assay method. Results: The mean change in serum K levels was -0.04 mmol/L (95% CI -0.14 to 0.06). The maximum increase was 1.10 mmol/L. The serum K level rose in 46 cases, decreased in 46 cases, and was unchanged in eight cases. No instance of SCh-induced cardiac arrest was identified. Conclusion: Changes in serum K levels following SCh administration in prescreened ED patients were minimal. A hyperkalemic response is uncommon in ED patients who undergo SCh-assisted intubation.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/75073/1/j.1553-2712.1995.tb03124.x.pd

    The ROSAT All-Sky Survey: a Catalog of Clusters of Galaxies in a Region of 1 Ster around the South Galactic Pole

    Get PDF
    A field of 1.013 ster in the ROSAT all-sky survey (RASS), centered on the south galactic pole (SGP), has been searched in a systematic, objective manner for clusters of galaxies. The procedure relied on a correlation of the X-ray positions and properties of ROSAT sources with the distribution of galaxies in the COSMOS digitised data base, which was obtained by scanning the plates of the UK Schmidt IIIa-J optical southern sky survey. The study used the second ROSAT survey data base (RASS-2) and included several optical observing campaigns to measure redshifts. The search, a precursor to the larger REFLEX survey of the whole southern sky, reached the detection limits of the RASS and the COSMOS data, and yielded a catalog of 186 clusters in which the lowest flux is 1.5e-12 erg/cm2/s in the 0.1-2.4 keV band. Of these 157 have measured redshifts. Using a limit of 3.0e-12 erg/cm2/s a complete subset of 112 clusters was obtained, of which 110 have measured redshifts. The spatial distribution of the X-ray clusters out to z = 0.15 shows an extension of the Local Supercluster to the Pisces-Cetus supercluster (z<~0.07), and a more distant orthogonal structure at 0.07<z<0.15.Comment: To be published in ApJ Supplements in February 2002: 53 pages: 18 figure

    Quasi-Periodic Occultation by a Precessing Accretion Disk and Other Variabilities of SMC X-1

    Full text link
    We have investigated the variability of the binary X-ray pulsar, SMC X-1, in data from several X-ray observatories. We confirm the ~60-day cyclic variation of the X-ray flux in the long-term monitoring data from the RXTE and CGRO observatories. X-ray light curves and spectra from the ROSAT, Ginga, and ASCA observatories show that the uneclipsed flux varies by as much as a factor of twenty between a high-flux state when 0.71 second pulses are present and a low-flux state when pulses are absent. In contrast, during eclipses when the X-rays consist of radiation scattered from circumsource matter, the fluxes and spectra in the high and low states are approximately the same. These observations prove that the low state of SMC X-1 is not caused by a reduction in the intrinsic luminosity of the source, or a spectral redistribution thereof, but rather by a quasi-periodic blockage of the line of sight, most likely by a precessing tilted accretion disk. In each of two observations in the midst of low states a brief increase in the X-ray flux and reappearance of 0.71 second pulses occurred near orbital phase 0.2. These brief increases result from an opening of the line of sight to the pulsar that may be caused by wobble in the precessing accretion disk. The records of spin up of the neutron star and decay of the binary orbit are extended during 1991-1996 by pulse-timing analysis of ROSAT, ASCA, and RXTE PCA data. The pulse profiles in various energy ranges from 0.1 to >21 keV are well represented as a combination of a pencil beam and a fan beam. Finally, there is a marked difference between the power spectra of random fluctuations in the high-state data from the RXTE PCA below and above 3.4 keV. Deviation from the fitted power law around 0.06 Hz may be QPO.Comment: Accepted to ApJ. 33 pages including 11 figure

    A Search for Aperiodic Millisecond Variability in Cygnus X-1

    Get PDF
    We have conducted a search for aperiodic millisecond variability in the integrated 1 to 25 keV X-ray region of Cyg X-1. We have examined HEAO A-1 archival data and Rossi X-ray Timing Explorer (RXTE) guest observer data for evidence of excess power above the Poisson noise floor using the relative integral power analysis and the Fourier transform method. Our results are in disagreement with the results of Meekins et al. (1984). We attribute the discrepancy to an instrumental effect for which Meekins et al.(1984) did not apply a correction. With the correction we see no evidence for excess power above 25 Hz in the HEAO A-1 data. Our analysis of RXTE data is in agreement with previously published results of different data sets and shows no sign of excess power above 30 Hz.Comment: 29 pages, 12 figures, to be submitted to Ap
    corecore