81 research outputs found

    Determining the Optical Geometry of a Gold Semi-Shell under the Kretschmann Configuration

    Get PDF
    Dielectric nanoparticles coated with metals (half-shell or semi-shell structures) have attracted attention as potential composite plasmonic nanomaterials with large optical anisotropy and absorption cross-sections. Structures approximately 100 nm in size can excite plasmons in the visible and near-infrared ranges, highlighting their distinct optical properties. This study employed metal semi-shell structures (metal: gold, dielectric: silica) in the Kretschmann configuration to experimentally and numerically demonstrate the optical determination of single-structure orientations through a finite-difference time-domain method. Gold semi-shell structures were fabricated through deposition and etching. These structures were removed from their substrate in ultrapure water and randomly dropped onto a thin gold substrate. In the single structure, we experimentally observed changes in the scattering light spectrum based on the optical geometry of the gold semi-shell at wavelengths ranging from 530 to 700 nm. The obtained results closely resembled those of a simulation and confirmed the presence of eigenmodes in the orientation through electric field analysis. These observations allow for the cost-effective and rapid determination of the orientations of numerous structures that are approximately 100 nm in size, solely through optical methods. This technique is a valuable development for measurement applications in nanostructure orientation control and functionality enhancement

    Fabrication of single-crystalline plasmonic nanostructures on transparent and flexible amorphous substrates

    Get PDF
    A new experimental technique is developed for producing a high-performance single-crystalline Ag nanostructure on transparent and flexible amorphous substrates for use in plasmonic sensors and circuit components. This technique is based on the epitaxial growth of Ag on a (001)-oriented single-crystalline NaCl substrate, which is subsequently dissolved in ultrapure water to allow the Ag film to be transferred onto a wide range of different substrates. Focused ion beam milling is then used to create an Ag nanoarray structure consisting of 200 cuboid nanoparticles with a side length of 160 nm and sharp, precise edges. This array exhibits a strong signal and a sharp peak in plasmonic properties and Raman intensity when compared with a polycrystalline Ag nanoarray

    A Case of Dominant Dystrophic Epidermolysis Bullosa with a G2043R Mutation in the Type VII Collagen Gene

    Get PDF
    Dystrophic epidermolysis bullosa (DEB) is a subepidermal bulla, characterized by severe itching, lichenoid or nodular prurigo-like lesions, skin erosion, scars, milia, and nail dystrophy, resulting from COL7A1 mutation. Herein, we report a case of dominant DEB with a G2043R mutation in COL7A1

    Phase Equilibrium in the Er-Fe-O System at 1100℃

    Get PDF
    Phase equilibrium was established in the Er-Fe-O system at 1100℃ by altering the oxygen partial pressure from -log(Po_2/atm)= 15.00 to 0, allowing construction of a phase diagram at 1100℃ for the system Er_20_3-Fe-Fe_2O_3. In the system, two ternary compounds, ErFeO_3 and Er_3Fe_50_12, were deemed stable and had nonstoichiometric composition, whereas ErFe_20_4 was not found to be stable. The present result was different from that of previous studies at 1200 ℃, in which ErFe_20_4 was stable along with the above two ternary compounds. Lattice constants of ErFeO_3 and Er_3Fe_50_12, prepared in air by a quenching method, were determined and compared with previous values, and showed slight differences. The Gibbs energy changes of the reactions in the Fe-0 system, Fe + 1/2 O_2 = FeO, 3 FeO + 1/2 0_2 = Fe_30_4, and 2/3 Fe_30_4 + 1/6 0_2 = Fe_20_3, were determined, and the obtained values were compared with the previous values. The Gibbs energy changes of the reactions, Fe + 1/2 Er_20_3 + 3/4 0_2 = ErFe0_3, and 3 ErFeO_3 + 2/3 Fe_3O_4 + 1/6 0_2 = Er_3Fe_50_12, were calculated from the oxygen partial pressures in equilibrium

    Expansion Velocity of Ejecta in Tycho's Supernova Remnant Measured by Doppler Broadened X-ray Line Emission

    Full text link
    We show that the expansion of ejecta in Tycho's supernova remnant (SNR) is consistent with a spherically symmetric shell, based on Suzaku measurements of the Doppler broadened X-ray emission lines. All the strong K_alpha line emission show broader widths at the center than at the rim, while the centroid energies are constant across the remnant (except for Ca). This is the pattern expected for Doppler broadening due to expansion of the SNR ejecta in a spherical shell. To determine the expansion velocities of the ejecta, we applied a model for each emission line feature having two Gaussian components separately representing red- and blue-shifted gas, and inferred the Doppler velocity difference between these two components directly from the fitted centroid energy difference. Taking into account the effect of projecting a three-dimensional shell to the plane of the detector, we derived average spherical expansion velocities independently for the K_alpha emission of Si, S, Ar, and Fe, and K_beta of Si. We found that the expansion velocities of Si, S, and Ar ejecta of 4700+/-100 km/s are distinctly higher than that obtained from Fe K_alpha emission, 4000+/-300 km/s, which is consistent with segregation of the Fe in the inner ejecta. Combining the observed ejecta velocities with the ejecta proper-motion measurements by Chandra, we derived a distance to the Tycho's SNR of 4+/-1 kpc.Comment: Accepted to Apj, 25 pages, 7 figures, 5 table

    Imiquimod for Cervical and Vaginal Intraepithelial Neoplasia: A Systematic Review and Meta-analysis.

    Get PDF
    OBJECTIVE To evaluate the treatment efficacy and the risk of adverse events of imiquimod for cervical intraepithelial neoplasia (CIN) and vaginal intraepithelial neoplasia (VAIN), compared with placebo or no intervention. DATA SOURCES We searched Cochrane, PubMed, ISRCTN registry, ClinicalTrials.gov, and the World Health Organization International Clinical Trials Registry Platform up to November 23, 2022. METHODS OF STUDY SELECTION We included randomized controlled trials and prospective nonrandomized studies with control arms that investigated the efficacy of imiquimod for histologically confirmed CIN or VAIN. The primary outcomes were histologic regression of the disease (primary efficacy outcome) and treatment discontinuation due to side effects (primary safety outcome). We estimated pooled odds ratios (ORs) of imiquimod, compared with placebo or no intervention. We also conducted a meta-analysis of the proportions of patients with adverse events in the imiquimod arms. TABULATION, INTEGRATION, AND RESULTS Four studies contributed to the pooled OR for the primary efficacy outcome. An additional four studies were available for meta-analyses of proportions in the imiquimod arm. Imiquimod was associated with increased probability of regression (pooled OR 4.05, 95% CI 2.08-7.89). Pooled OR for CIN in the three studies was 4.27 (95% CI 2.11-8.66); results of one study were available for VAIN (OR, 2.67, 95% CI 0.36-19.71). Pooled probability for primary safety outcome in the imiquimod arm was 0.07 (95% CI 0.03-0.14). The pooled probabilities (95% CI) of secondary outcomes were 0.51 (0.20-0.81) for fever, 0.53 (0.31-0.73) for arthralgia or myalgia, 0.31 (0.18-0.47) for abdominal pain, 0.28 (0.09-0.61) for abnormal vaginal discharge or genital bleeding, 0.48 (0.16-0.82) for vulvovaginal pain, and 0.02 (0.01-0.06) for vaginal ulceration. CONCLUSION Imiquimod was found to be effective for CIN, whereas data on VAIN were limited. Although local and systemic complications are common, treatment discontinuation is infrequent. Thus, imiquimod is potentially an alternative therapy to surgery for CIN. SYSTEMATIC REVIEW REGISTRATION PROSPERO, CRD42022377982

    Comparison of Count Normalization Methods for Statistical Parametric Mapping Analysis Using a Digital Brain Phantom Obtained from Fluorodeoxyglucose-positron Emission Tomography

    Get PDF
    Objective(s): Alternative normalization methods were proposed to solve the biased information of SPM in the study of neurodegenerative disease. The objective of this study was to determine the most suitable count normalization method for SPM analysis of a neurodegenerative disease based on the results of different count normalization methods applied on a prepared digital phantom similar to one obtained using fluorodeoxyglucose-positron emission tomography (FDG-PET) data of a brain with a known neurodegenerative condition.Methods: Digital brain phantoms, mimicking mild and intermediate neurodegenerative disease conditions, were prepared from the FDG-PET data of 11 healthy subjects. SPM analysis was performed on these simulations using different count normalization methods. Results: In the slight-decrease phantom simulation, the Yakushev method correctly visualized wider areas of slightly decreased metabolism with the smallest artifacts of increased metabolism. Other count normalization methods were unable to identify this slightly decreases and produced more artifacts. The intermediate-decreased areas were well visualized by all methods. The areas surrounding the grey matter with the slight decreases were not visualized withthe GM and VOI count normalization methods but with the Andersson. The Yakushev method well visualized these areas. Artifacts were present in all methods. When the number of reference area extraction was increased, the Andersson method better-captured the areas with decreased metabolism and reduced the artifacts of increased metabolism. In the Yakushev method, increasing the threshold for the reference area extraction reduced such artifacts.Conclusion: The Yakushev method is the most suitable count normalization method for the SPM analysis of neurodegenerative disease

    The ASTRO-H X-ray Observatory

    Full text link
    The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions initiated by the Institute of Space and Astronautical Science (ISAS). ASTRO-H will investigate the physics of the high-energy universe via a suite of four instruments, covering a very wide energy range, from 0.3 keV to 600 keV. These instruments include a high-resolution, high-throughput spectrometer sensitive over 0.3-2 keV with high spectral resolution of Delta E < 7 eV, enabled by a micro-calorimeter array located in the focal plane of thin-foil X-ray optics; hard X-ray imaging spectrometers covering 5-80 keV, located in the focal plane of multilayer-coated, focusing hard X-ray mirrors; a wide-field imaging spectrometer sensitive over 0.4-12 keV, with an X-ray CCD camera in the focal plane of a soft X-ray telescope; and a non-focusing Compton-camera type soft gamma-ray detector, sensitive in the 40-600 keV band. The simultaneous broad bandpass, coupled with high spectral resolution, will enable the pursuit of a wide variety of important science themes.Comment: 22 pages, 17 figures, Proceedings of the SPIE Astronomical Instrumentation "Space Telescopes and Instrumentation 2012: Ultraviolet to Gamma Ray
    corecore