546 research outputs found

    <LECTURES>Formation of Prototype for Chinese Medicine

    Get PDF

    Influence of container structures and content solutions on dispensing time of ophthalmic solutions

    Get PDF
    Keiji Yoshikawa1, Hiroshi Yamada21Yoshikawa Eye Clinic, Tokyo, Japan; 2Santen Pharmaceutical Co., Ltd., Osaka, JapanPurpose: To investigate the influence of container structures and content solutions on the time of dispensing from eye dropper bottles.Methods: Eye dropper bottle models, solution models (filtrate water/surfactant solution) and a dispensing time measuring apparatus were prepared to measure the dispensing time.Results: With filtrate water and pressure thrust load of 0.3 MPa, the dispensing time significantly increased from 1.1 &amp;plusmn; 0.5 seconds to 4.6 &amp;plusmn; 1.1 seconds depending on the decrease of inner aperture diameters from 0.4 mm to 0.2 mm (P &amp;lt; 0.0001). When using the bottle models with inner aperture diameters of 0.4 mm or larger, the dispensing time became constant. The dispensing time using surfactant solution showed the same tendency as above. When pressure thrust load was large (0.07 MPa), the solution flew out continuously with inner aperture diameters of 0.4 mm or larger and the dispensing time could not be measured. The inner aperture diameter most strongly explained the variation of the dispensing time in both the content solutions in the multiple linear regression analysis (filtrate water: 46%, R2 = 0.462, surfactant solution: 56%, R2 = 0.563).Conclusions: Among content solutions and container structures, the dispensing time was mostly influenced by the diameter of the inner aperture of bottles.Keywords: dispensing time, model eye dropper bottle, model ophthalmic solution, nozzle internal space volume, nozzle inner aperture diamete

    Application of permanents of square matrices for DNA identification in multiple-fatality cases.

    Get PDF
    [Background]DNA profiling is essential for individual identification. In forensic medicine, the likelihood ratio (LR) is commonly used to identify individuals. The LR is calculated by comparing two hypotheses for the sample DNA: that the sample DNA is identical or related to a reference DNA, and that it is randomly sampled from a population. For multiple-fatality cases, however, identification should be considered as an assignment problem, and a particular sample and reference pair should therefore be compared with other possibilities conditional on the entire dataset. [Results]We developed a new method to compute the probability via permanents of square matrices of nonnegative entries. As the exact permanent is known as a #P-complete problem, we applied the Huber–Law algorithm to approximate the permanents. We performed a computer simulation to evaluate the performance of our method via receiver operating characteristic curve analysis compared with LR under the assumption of a closed incident. Differences between the two methods were well demonstrated when references provided neither obligate alleles nor impossible alleles. The new method exhibited higher sensitivity (0.188 vs. 0.055) at a threshold value of 0.999, at which specificity was 1, and it exhibited higher area under a receiver operating characteristic curve (0.990 vs. 0.959, P = 9.6E-15). [Conclusions]Our method therefore offers a solution for a computationally intensive assignment problem and may be a viable alternative to LR-based identification for closed-incident multiple-fatality cases

    From the Editor

    Get PDF

    The Origins of Acupuncture, Moxibustion, and Decoction

    Get PDF

    The Intellectual Isolation and Opening of Japan and China

    Get PDF

    Modern science and technology in 18th and 19th century Japan

    Get PDF
    Istambul, 1996年10月7日-11

    Reversal of Large Ischemic Injury on Hyper-Acute Diffusion MRI

    Get PDF
    www.karger.com/crn This is an Open Access article licensed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 3.0 License (www.karger.com/OA-license), applicable to the online version of the article only. Distribution for non-commercial purposes only

    Modified inverse square sensitometry for the determination of the characteristic curve of radiographic screen/film systems.

    Get PDF
    To determine the characteristic curve of the radiographic screen/film systems in a short focal spot-film distance, the inverse square sensitometric method was modified by changing the radiation intensity with two kinds of filters. The characteristic curves obtained in the two exposure series with these two kinds of filters were overlapped to obtain a complete one. The characteristic curve thus obtained was almost the same as the one obtained by the original inverse square sensitometric method. The accuracy of the characteristic curves obtained by the modified method was well-reflected in the clinical radiographs.</p
    corecore