74 research outputs found

    Fluorine-free and hydrophobic hexadecyltrimethoxysilane-TiO<sub>2</sub> coated mesh for gravity-driven oil/water separation

    Get PDF
    Superhydrophobic and superoleophilic meshes have attracted great attention in oil/water separating application. However, superhydrophobic surfaces are not only complicated in preparation but also easy to break in practical applications. In this paper, we prepared fluorine-free hydrophobic hexadecyltrimethoxysilane (HDTMS)-TiO2 coated meshes with properties of cost-effectiveness, easy to manufacture, and high separation efficiency by a liquid phase deposition method. The surface topography, composition, and functional groups of the meshes were characterized by field emission scanning electron microscope (FE-SEM), energy dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), and Fourier transform microscopic infrared spectrometer (FT-IR) spectrum, respectively. A new gravity-driven oil/water separator was designed for the separation experiments. The separation efficiency of the hydrophobic HDTMS-TiO2 coated meshes maintained over 97.8% after 35 separating cycles. This study indicated that the superhydrophobicity of the separating mesh was nonessential for the highly efficient oil-water separation. The fluorine-free hydrophobic HDTMS-TiO2 coated meshes provided an economical and beneficial solution to treat industrial oily wastewater mixtures and environmental oil spills.</p

    Endothelial nitric oxide synthase expression is progressively increased in primary cerebral microvascular endothelial cells during hyperbaric oxygen exposure

    Get PDF
    Exposure to hyperbaric oxygen (HBO) can lead to seizures. Many studies have demonstrated that there exist a very close relationship between the alteration of cerebral blood flow (CBF) and the onset of seizures. Nitric oxide (NO) may play a key role in the change of CBF during exposure, and modulation of endothelial nitric oxide synthase (eNOS)-derived NO by HBO is responsible for early vasoconstriction, whereas late HBO-induced vasodilation depends upon a large amount of NO from both eNOS and neuronal nitric oxide synthase (nNOS). To investigate the effect of HBO on the activity and expression of eNOS in cerebral microvascular endothelial cells (CMEC) in vitro, primarily cultured CMEC from neonatal rats were exposed to oxygen at 500 kPa [5 atmosphere absolute (ATA)] for 10, 20, 30, 60 and 120 minutes (min), then eNOS activity, protein and mRNA contents in cells were detected. Our results showed that immediately after exposure, 30, 60 and 120 min HBO exposures did not alter NOS activity. When detected no matter immediately or six hours (h) after exposure, these exposures also did not alter eNOS protein and mRNA levels. However, when detected 24 h after exposure, 30, 60 and 120 min exposures upregulated eNOS protein content by 39%, 60% and 40% respectively. 10 and 20 min exposures upregulated eNOS mRNA content by about 15%, while 30, 60 and 120 min exposures upregulated it by about 20–30%. The increased eNOS protein and mRNA contents at 24 h after exposure may reflect new protein synthesis for eNOS. Our studies showed that with the exposing protocols we used, HBO did induce eNOS expression increase in CMEC. However, compared with the decrease of CBF in vivo, which occurred in a relative short time after rat was exposed to HBO above 4 ATA, the responses of eNOS in CMEC in vitro were a little slow. Thus we considered that for the vasodilation in the late period of HBO exposure before seizure, the effect of NO produced by eNOS was limited

    Genetic Variation of Promoter Sequence Modulates XBP1 Expression and Genetic Risk for Vitiligo

    Get PDF
    Our previous genome-wide linkage analysis identified a susceptibility locus for generalized vitiligo on 22q12. To search for susceptibility genes within the locus, we investigated a biological candidate gene, X-box binding protein 1(XBP1). First, we sequenced all the exons, exon-intron boundaries as well as some 5′ and 3′ flanking sequences of XBP1 in 319 cases and 294 controls of Chinese Hans. Of the 8 common variants identified, the significant association was observed at rs2269577 (p_trend = 0.007, OR = 1.36, 95% CI = 1.09–1.71), a putative regulatory polymorphism within the promoter region of XBP1. We then sequenced the variant in an additional 365 cases and 404 controls and found supporting evidence for the association (p_trend = 0.008, OR = 1.31, 95% CI = 1.07–1.59). To further validate the association, we genotyped the variant in another independent sample of 1,402 cases and 1,288 controls, including 94 parent-child trios, and confirmed the association by both case-control analysis (p_trend = 0.003, OR = 1.18, 95% CI = 1.06–1.32) and the family-based transmission disequilibrium test (TDT, p = 0.005, OR = 1.93, 95% CI = 1.21–3.07). The analysis of the combined 2,086 cases and 1,986 controls provided highly significant evidence for the association (p_trend = 2.94×10−6, OR = 1.23, 95% CI = 1.13–1.35). Furthermore, we also found suggestive epistatic effect between rs2269577 and HLA-DRB1*07 allele on the development of vitiligo (p = 0.033). Our subsequent functional study showed that the risk-associated C allele of rs2269577 had a stronger promoter activity than the non-risk G allele, and there was an elevated expression of XBP1 in the lesional skins of patients carrying the risk-associated C allele. Therefore, our study has demonstrated that the transcriptional modulation of XBP1 expression by a germ-line regulatory polymorphism has an impact on the development of vitiligo

    Experimental Study and Finite Element Calculation of the Behavior of Special T-Shaped Composite Columns with Concrete-Filled Square Steel Tubulars under Eccentric Loads

    No full text
    Special T-shaped composite columns with concrete-filled square steel tubulars have good restraint on internal concrete, are convenient to process, have a high bearing capacity and good mechanical properties, and can increase the aesthetics of the building and the utilization rate of indoor space. Theoretical analysis, experimental study, and numerical simulation of the eccentric compression performance of the special-shaped column are carried out. Taking the specimen length, eccentric distance, and eccentric direction as test parameters, nine specimens with different slenderness ratios were designed to carry out eccentric compression tests. The eccentric compression performance was numerically simulated and analyzed by the general finite element software ABAQUS. The results show that the short column mainly suffers section strength failure, while the middle and long columns mainly suffer bending instability failure without torsional deformation. The degree of influence of the test parameters decreases in turn according to the eccentric distance, eccentric direction, and length of the specimen; there is no weld cracking phenomenon, and the square steel pipes can work together. The finite element calculation results are in good agreement with the experimental and theoretical values

    Experimental Study and Finite Element Calculation of the Behavior of Special T-Shaped Composite Columns with Concrete-Filled Square Steel Tubulars under Eccentric Loads

    No full text
    Special T-shaped composite columns with concrete-filled square steel tubulars have good restraint on internal concrete, are convenient to process, have a high bearing capacity and good mechanical properties, and can increase the aesthetics of the building and the utilization rate of indoor space. Theoretical analysis, experimental study, and numerical simulation of the eccentric compression performance of the special-shaped column are carried out. Taking the specimen length, eccentric distance, and eccentric direction as test parameters, nine specimens with different slenderness ratios were designed to carry out eccentric compression tests. The eccentric compression performance was numerically simulated and analyzed by the general finite element software ABAQUS. The results show that the short column mainly suffers section strength failure, while the middle and long columns mainly suffer bending instability failure without torsional deformation. The degree of influence of the test parameters decreases in turn according to the eccentric distance, eccentric direction, and length of the specimen; there is no weld cracking phenomenon, and the square steel pipes can work together. The finite element calculation results are in good agreement with the experimental and theoretical values

    Abnormal brain white matter in patients with right trigeminal neuralgia: a diffusion tensor imaging study

    No full text
    Abstract Background Idiopathic or classical trigeminal neuralgia (TN) is a chronic painful condition characterized by intermittent pain attacks. Enough evidence demonstrates classical TN is related to neurovascular compression (NVC) at the trigeminal root entry zone (REZ), but white matter change secondary to TN are not totally known. Methods Visual Analogue Scale (VAS) and diffusion tensor imaging were performed on 29 patients with right TN and 35 healthy individuals. Voxel-wise analyses were performed with TBSS using multiple diffusion metrics, including fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD) and radial diffusivity (RD). Group differences in these parameters were compared between right TN patients and controls using TBSS and correlations between the white matter change and disease duration and VAS in right TN patients were assessed. Multiple comparison correction were applied to test significant correlations. Results The right TN patients showed significantly lower FA and higher RD in most left white matter (P < 0.05, FWE corrected). Moreover, negative correlations were observed between disease duration and the FA values of left corona radiata, genu of corpus callosum, left external capsule and left cerebral peduncle, and between VAS and the FA values of left corona radiata, left external capsule and left cerebral peduncle (P < 0.05). Positive correlations were observed for disease duration and the RD values of left corona radiata, right external capsule, left fornix cerebri and left cerebral peduncle, and for VAS and the RD values of left corona radiata and left external capsule (P < 0.05). However, once Bonferroni corrections were applied, these correlations were not statistically significant. Conclusion These findings suggest that TN selectively impairs widespread white matter, especially contralateral hemisphere, which may be the hallmark of disease severity in TN patients
    • …
    corecore