30 research outputs found

    Gastric Helicobacter pylori infection perturbs human oral microbiota

    Get PDF
    Background We investigated the effects of gastric Helicobacter pylori infection on the daytime and overnight human oral microbiota. Methods Twenty four volunteers were recruited. Ten tested positive for H. pylori infection by the Carbon-14 Urea Breath Test, and the rest were negative. Two oral swabs were collected: one immediately after waking up in the morning and before brushing teeth, and another in the evening before teeth-brushing. DNA extract acquired from each swab was subjected to Illumina sequencing of 16S rRNA gene amplicons. The microbial abundance and composition were analysed in relation to H. pylori infection status. Results Helicobacter pylori-positive individuals had significant changes in the alpha and beta diversities in the daytime samples in comparison to those who were H. pylori negative. To identify which taxa could be significantly affected within the cohorts in the daytime, we employed the LEfSe method. When compared against UBT-negative samples, significantly higher abundances were detected in both Pseudomonas and Roseomonas, while Fusobacterium, Solobacterium, Haemophilus and Streptococcus were significantly decreased in the UBT-positive samples. Discussion Our data demonstrated that H. pylori infection affects the human daytime oral microbiota. The hitherto undocumented changes of several bacterial genera due to H. pylori infection require more studies to examine their potential health effects on affected individuals

    The impact of probiotic supplementation on cognitive, pathological and metabolic markers in a transgenic mouse model of Alzheimer’s Disease

    Get PDF
    Brain degenerative disorders such as Alzheimer’s disease (AD) can be exacerbated by aberrant metabolism. Supplementation with probiotic bacteria is emerging as a promising preventative strategy for both neurodegeneration and metabolic syndrome. In this study, we assess the impact of the Lab4b probiotic consortium on (i) cognitive and pathological markers of AD progression and (ii) metabolic status in 3xTg-AD mice subjected to metabolic challenge with a high fat diet. The group receiving the probiotic performed better in the novel object recognition test and displayed higher hippocampal neuronal spine density than the control group at the end of the 12 weeks intervention period. These changes were accompanied by differences in localised (brain) and systemic anti-inflammatory responses that favoured the Probiotic group together with the prevention of diet induced weight gain and hypercholesterolaemia and the modulation of liver function. Compositional differences between the faecal microbiotas of the study groups included a lower Firmicutes:Bacteroidetes ratio and less numbers of viable yeast in the Probiotic group compared to the Control. The results illustrate the potential of the Lab4b probiotic as a neuroprotective agent and encourage further studies with human participants

    COVID-19: Rapid antigen detection for SARS-CoV-2 by lateral flow assay: A national systematic evaluation of sensitivity and specificity for mass-testing

    Get PDF
    Background Lateral flow device (LFD) viral antigen immunoassays have been developed around the world as diagnostic tests for SARS-CoV-2 infection. They have been proposed to deliver an infrastructure-light, cost-economical solution giving results within half an hour. Methods LFDs were initially reviewed by a Department of Health and Social Care team, part of the UK government, from which 64 were selected for further evaluation from 1st August to 15th December 2020. Standardised laboratory evaluations, and for those that met the published criteria, field testing in the Falcon-C19 research study and UK pilots were performed (UK COVID-19 testing centres, hospital, schools, armed forces). Findings 4/64 LFDs so far have desirable performance characteristics (orient Gene, Deepblue, Abbott and Innova SARS-CoV-2 Antigen Rapid Qualitative Test). All these LFDs have a viral antigen detection of >90% at 100,000 RNA copies/ml. 8951 Innova LFD tests were performed with a kit failure rate of 5.6% (502/8951, 95% CI: 5.1–6.1), false positive rate of 0.32% (22/6954, 95% CI: 0.20–0.48). Viral antigen detection/sensitivity across the sampling cohort when performed by laboratory scientists was 78.8% (156/198, 95% CI 72.4–84.3). Interpretation Our results suggest LFDs have promising performance characteristics for mass population testing and can be used to identify infectious positive individuals. The Innova LFD shows good viral antigen detection/sensitivity with excellent specificity, although kit failure rates and the impact of training are potential issues. These results support the expanded evaluation of LFDs, and assessment of greater access to testing on COVID-19 transmission. Funding Department of Health and Social Care. University of Oxford. Public Health England Porton Down, Manchester University NHS Foundation Trust, National Institute of Health Research

    The potential of computerised analysis of bowel sounds for diagnosis of gastrointestinal conditions: a systematic review

    No full text
    Abstract Background Gastrointestinal (GI) conditions are highly prevalent, and their standard diagnostic tests are costly and carry risks. There is a need for new, cost-effective, non-invasive tests. Our main objective was to assess the potential for use of bowel sounds computerised analysis in the diagnosis of GI conditions. Methods The systematic review followed the PRISMA requirements. Searches were made of four databases (PubMed, MEDLINE, Embase, and IEEE Xplore) and the references of included papers. Studies of all types were included. The titles and abstracts were screened by one author. Full articles were reviewed and data collected by two authors independently. A third reviewer decided on inclusion in the event of disagreement. Bias and applicability were assessed via a QUADAS tool adapted to accommodate studies of multiple types. Results Two thousand eight hundred eighty-four studies were retrieved; however, only 14 studies were included. Most of these simply assessed associations between a bowel sound feature and a condition. Four studies also included assessments of diagnostic accuracy. We found many significant associations between a bowel sound feature and a GI condition. Receiver operating characteristic curve analyses revealed high sensitivity and specificity for an irritable bowel syndrome test, and a high negative predictive value for a test for post-operative ileus. Assessment of methodological quality identified weaknesses in all studies. We particularly noted a high risk of bias in patient selection. Because of the limited number of trials included and the variety in conditions, technology, and statistics, we were unable to conduct pooled analyses. Conclusions Due to concerns over quality and small sample sizes, we cannot yet recommend an existing BSCA diagnostic test without additional studies. However, the preliminary results found in the included studies and the technological advances described in excluded studies indicate excellent future potential. Research combining sophistical clinical and engineering skills is likely to be fruitful. Systematic review registration The review protocol (review ID number 42016054028) was developed by three authors (AI, KMW, and JM) and was published in the PROSPERO International prospective register of systematic reviews. It can be accessed from https://www.crd.york.ac.uk/PROSPERO/

    A mathematical model of bowel sound generation

    No full text
    Humans have been interested in bowel sounds and wondered about their origins for millennia. To better understand the phenomenon, a mathematical model of bowel sound generation was developed based on a spring-mass-damping system. This is similar to vocal folds models for speech. The bowel sound model has four parameters that link to bowel activities: the individual wave component, pressure index, component quantity, and component interval time. All types of bowel sound documented previously can be modelled by combining different values for these parameters. Further, a 2500 ms bowel sound incorporating all the common types was simulated to present the model\u27s accuracy
    corecore