83 research outputs found

    Geometry Optimization in Polarizable QM/MM Models: The Induced Dipole Formulation

    Get PDF
    We present the mathematical derivation and the computational implementation of the analytical geometry derivatives for a polarizable QM/MM model (QM/MMPol). In the adopted QM/MMPol model, the focused part is treated at QM level of theory, while the remaining part (the environment) is described classically as a set of fixed charges and induced dipoles. The implementation is performed within the ONIOM procedure, resulting in a polarizable embedding scheme, which can be applied to solvated and embedded systems and combined with different polarizable force fields available in the literature. Two test cases characterized by strong hydrogen-bond and dipole-dipole interactions, respectively, are used to validate the method with respect to the nonpolarizable one. Finally, an application to geometry optimization of the chromophore of Rhodopsin is presented to investigate the impact of including mutual polarization between the QM and the classical parts in conjugated systems

    Psychological Health Status of Psychiatric Patients Living in Treatment Communities before and during the COVID-19 Lockdown: A Brief Report

    Get PDF
    Many studies investigated the psychological impact of lockdown measures on the general population, while few studies focused on the psychiatric population. This study aimed to investigate the role of therapeutic communities in the management and containment of symptoms of patients with psychosis living in psychiatric residential facilities. Data were collected at two different points: November 2019 (Coronavirus disease 19 had not yet spread) and April 2020 (during the lockdown in Italy). Twenty-two study participants were recruited from three residential accredited psychiatric facilities. During lockdown, the patients showed a small increase in symptomatology in terms of emotional isolation. In addition, it was been observed significant differences in certain functional areas of the behavior, measured as lower inclination towards violent behaviors during lockdown, and higher scores in substance abuse and medical impairment. The lockdown condition could represent a form of containment; daily routines, along with adequate social support, are important aspects of the stability and the level of behavioral functioning of psychiatric patients. Social support and continuity of care offered by psychiatric communities can be an effective safeguard against the psychological impact of the COVID-19 epidemic

    Acute shock efficacy of the subcutaneous implantable cardioverter-defibrillator according to the implantation technique

    Get PDF
    Background: The traditional technique for subcutaneous implantable cardioverter defibrillator (S-ICD) implantation involves three incisions and a subcutaneous (SC) pocket. An intermuscular (IM) 2-incision technique has been recently adopted. Aims: We assessed acute defibrillation efficacy (DE) of S-ICD (DE ≤65 J) according to the implantation technique. Methods: We analyzed consecutive patients who underwent S-ICD implantation and DE testing at 53 Italian centers. Regression analysis was used to determine the association between DFT and implantation technique. Results: A total of 805 patients were enrolled. Four groups were assessed: IM + 2 incisions (n = 546), SC + 2 incisions (n = 133), SC + 3 incisions (n = 111), and IM + 3 incisions (n = 15). DE was ≤65 J in 782 (97.1%) patients. Patients with DE ≤65 J showed a trend towards lower body mass index (25.1 vs. 26.5; p = .12), were less frequently on antiarrhythmic drugs (13% vs. 26%; p = .06) and more commonly underwent implantation with the 2-incision technique (85% vs. 70%; p = .04). The IM + 2-incision technique showed the lowest defibrillation failure rate (2.2%) and shock impedance (66 Ohm, interquartile range: 57-77). On multivariate analysis, the 2-incision technique was associated with a lower incidence of shock failure (hazard ratio: 0.305; 95% confidence interval: 0.102-0.907; p = .033). Shock impedance was lower with the IM than with the SC approach (66 vs. 70 Ohm p = .002) and with the 2-incision than the 3-incision technique (67 vs. 72 Ohm; p = .006). Conclusions: In a large population of S-ICD patients, we observed a high defibrillation success rate. The IM + 2-incision technique provides lower shock impedance and a higher likelihood of successful defibrillation

    The "Defibrillation Testing, Why Not?" survey. Testing of subcutaneous and transvenous defibrillators in the Italian clinical practice

    Get PDF
    Background: Defibrillation testing (DT) can be omitted in patients undergoing transvenous implantable cardioverter-defibrillator (T-ICD) implantation, but it is still recommended for patients at risk for a high defibrillation threshold and for ICD generator changes. Moreover, DT is still recommended on implantation of subcutaneous ICD (S-ICD). The aim of the present survey was to analyze the current practice of DT during T-ICD and S-ICD implantations.Methods: In March 2021, an ad hoc questionnaire on the current performance of DT and the standard practice adopted during testing was completed at 72 Italian centers implanting S-ICD and T-ICD.Results: 48 (67%) operators reported never performing DT during de-novo T-ICD implantations, while no operators perform it systematically. The remaining respondents perform it for patients at risk for a high defibrillation threshold. DT is never performed at T-ICD generator change. At the time of de-novo S-ICD implantation, DT is never performed by 9 (13%) operators and performed systematically by 48 (66%). The remaining operators frequently omit DT in patients with more severe systolic dysfunction. DT is not performed at S-ICD generator change by 92% of operators. DT is conducted by delivering a first shock energy of 65 J by 60% of operators, while the remaining 40% test lower energy values.Conclusions: In current clinical practice, most operators omit DT at T-ICD implantation, even when still recommended in the guidelines. DT is also frequently omitted at S-ICD implantation, and a wide variability exists among operators in the procedures followed during DT

    Challenging point scanning across electron microscopy and optical imaging using computational imaging

    Get PDF
    Solving challenges of enhanced imaging (resolution or speed) is a continuously changing frontier of research. Within this sphere, ghost imaging (and the closely related single-pixel imaging) has evolved as an alternative to focal plane detector arrays owing to advances in detectors and/or modulation devices. The interest in these techniques is due to their robustness to varied sets of patterns and applicability to a broad range of wavelengths and compatibility with compressive sensing. To achieve a better control of illumination strategies, modulators of many kinds have long been available in the optical regime. However, analogous technology to control of phase and amplitude of electron beams does not exist. We approach this electron microscopy challenge from an optics perspective, with a novel approach to imaging with non-orthogonal pattern sets using ghost imaging. Assessed first in the optical regime and subsequently in electron microscopy, we present a methodology that is applicable at different spectral regions and robust to non-orthogonality. The distributed illumination pattern sets also result in a reduced peak intensity, thereby potentially reducing damage of samples during imaging. This imaging approach is potentially translatable beyond both regimes explored here, as a single-element detector system

    Adjuvant trastuzumab in the treatment of her-2-positive early breast cancer: a meta-analysis of published randomized trials

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Breast cancer is the most common cancer in women in the U.S. and Western Europe. Amplification of the her-2/neu gene occurs in approximately 25% of invasive ductal carcinomas of the breast. The first HER-2/neu-targeted approach to reach the clinic was trastuzumab, a humanized monoclonal antibody directed against the extracellular domain of the HER-2/neu protein. Trastuzumab therapy prolongs the survival of patients with metastático HER-2/neu-overexpressing breast cancer when combined with chemotherapy and has recently been demonstrated to lead to dramatic improvements in disease-free survival when used in the adjuvant therapy setting in combination with or following chemotherapy. Here, we performed a meta-analysis of completed clinical trials of adjuvant trastuzumab in the adjuvant setting. Survival, recurrence, brain metastases, cardiotoxicity and directions for future research are discussed.</p> <p>Methods</p> <p>A meta-analysis of randomized controlled trials (RCT) was performed comparing adjuvant trastuzumab treatment for HER2-positive early breast cancer (EBC) to observation. The MEDLINE, EMBASE, CANCERLIT and Cochrane Library databases, and abstracts published in the annual proceedings were systematically searched for evidence. Relevant reports were reviewed by two reviewers independently and the references from these reports were searched for additional trials, using guidelines set by QUOROM statement criteria.</p> <p>Results</p> <p>Pooled results from that five randomized trials of adjuvant Trastuzumab showed a significant reduction of mortality (p < 0.00001), recurrence (p < 0.00001), metastases rates (p < 0.00001) and second tumors other than breast cancer (p = 0.007) as compared to no adjuvant Trastuzumab patients. There were more grade III or IV cardiac toxicity after trastuzumab (203/4555 = 4.5%) versus no trastuzumab (86/4562 = 1.8%). The likelihood of cardiac toxicity was 2.45-fold higher (95% CI 1.89 – 3.16) in trastuzumab arms, however that result was associated with heterogeneity. The likelihood of brain metastases was 1.82-fold higher (95% CI 1.16 – 2.85) in patients who received trastuzumab.</p> <p>Conclusion</p> <p>The results from this meta-analysis are sufficiently compelling to consider 1 year of adjuvant trastuzumab treatment for women with HER-2-positive EBC based on the risk: benefit ratio demonstrated in these studies. Adequate assessment of HER-2/neu status is critical, and careful cardiac monitoring is warranted because of cardiac toxicity. Clinical trials should be designed to answer unsolved questions.</p

    Whole brain radiotherapy with radiosensitizer for brain metastases

    Get PDF
    <p>Abstract</p> <p>Purpose</p> <p>To study the efficacy of whole brain radiotherapy (WBRT) with radiosensitizer in comparison with WBRT alone for patients with brain metastases in terms of overall survival, disease progression, response to treatment and adverse effects of treatment.</p> <p>Methods</p> <p>A meta-analysis of randomized controlled trials (RCT) was performed in order to compare WBRT with radiosensitizer for brain metastases and WBRT alone. The MEDLINE, EMBASE, LILACS, and Cochrane Library databases, in addition to Trial registers, bibliographic databases, and recent issues of relevant journals were researched. Significant reports were reviewed by two reviewers independently.</p> <p>Results</p> <p>A total of 8 RCTs, yielding 2317 patients were analyzed. Pooled results from this 8 RCTs of WBRT with radiosensitizer have not shown a meaningful improvement on overall survival compared to WBRT alone OR = 1.03 (95% CI0.84–1.25, p = 0.77). Also, there was no difference in local brain tumor response OR = 0.8(95% CI 0.5 – 1.03) and brain tumor progression (OR = 1.11, 95% CI 0.9 – 1.3) when the two arms were compared.</p> <p>Conclusion</p> <p>Our data show that WBRT with the following radiosentizers (ionidamine, metronidazole, misonodazole, motexafin gadolinium, BUdr, efaproxiral, thalidomide), have not improved significatively the overall survival, local control and tumor response compared to WBRT alone for brain metastases. However, 2 of them, motexafin- gadolinium and efaproxiral have been shown in recent publications (lung and breast) to have positive action in lung and breast carcinoma brain metastases in association with WBRT.</p

    Brachytherapy for cervix cancer: low-dose rate or high-dose rate brachytherapy – a meta-analysis of clinical trials

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The literature supporting high-dose rate brachytherapy (HDR) in the treatment of cervical carcinoma derives primarily from retrospective series. However, controversy still persists regarding the efficacy and safety of HDR brachytherapy compared to low-dose rate (LDR) brachytherapy, in particular, due to inadequate tumor coverage for stage III patients. Whether LDR or HDR brachytherapy produces better results for these patients in terms of survival rate, local control rate and the treatment complications remain controversial.</p> <p>Methods</p> <p>A meta-analysis of RCT was performed comparing LDR to HDR brachytherapy for cervix cancer treated for radiotherapy alone. The MEDLINE, EMBASE, CANCERLIT and Cochrane Library databases, as well as abstracts published in the annual proceedings were systematically searched. We assessed methodological quality for each outcome by grading the quality of evidence using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) methodology. We used "recommend" for strong recommendations, and "suggest" for weak recommendations.</p> <p>Results</p> <p>Pooled results from five randomized trials (2,065 patients) of HDR brachytherapy in cervix cancer showed no significant increase of mortality (p = 0.52), local recurrence (p = 0.68), or late complications (rectal; p = 0.7, bladder; p = 0.95 or small intestine; p = 0.06) rates as compared to LDR brachytherapy. In the subgroup analysis no difference was observed for overall mortality and local recurrence in patients with clinical stages I, II and III. The quality of evidence was low for mortality and local recurrence in patients with clinical stage I, and moderate for other clinical stages.</p> <p>Conclusion</p> <p>Our meta-analysis shows that there are no differences between HDR and LDR for overall survival, local recurrence and late complications for clinical stages I, II and III. By means of the GRADE system, we recommend the use of HDR for all clinical stages of cervix cancer.</p
    • …
    corecore