26 research outputs found

    Near-infrared reflectance imaging of neovascular age-related macular degeneration

    Get PDF
    Contains fulltext : 81007.pdf (publisher's version ) (Closed access)PURPOSE: To evaluate various types of neovascular age-related macular degeneration (AMD) by near-infrared fundus reflectance (NIR) as compared to fundus fluorescein angiography (FFA) and to test NIR for assessment of leakage due to choroidal neovascularization (CNV). PATIENTS AND METHODS: Thirty-three patients with neovascular AMD (cases) and 20 age-matched patients with non-exudative AMD and healthy subjects (controls) were examined with a confocal scanning laser ophthalmoscope (Heidelberg Retina Angiograph 2). NIR images of neovascular AMD were qualitatively compared to the corresponding FFA and to age-matched controls. CNV membranes and exudation areas were manually segmented on FFA and NIR and analyzed quantitatively. Results : Of all cases included, five eyes had classic CNV, six had minimal classic lesions, 15 occult CNV's and seven eyes had retinal angiomatous proliferation (RAP). A dark halo on NIR was found in all cases and showed high correspondence to leakage on FFA (r (2) = 0.93; p < 0,0005). In classic CNV and minimal classic CNV, the classic part of the lesion on FFA revealed strong correlation to a dark core surrounded by a bright reflecting ring on NIR (r (2) = 0.88; p < 0.0005). Occult parts on FFA of minimal classic CNV and occult CNV lesions appeared as poorly demarcated, jagged areas of increased NIR. RAP was characterized by speckled NIR located at the intraretinal neovascular complex. CONCLUSIONS: NIR imaging in neovascular AMD revealed characteristic alterations depending on the type of CNV. These changes may reflect histological differences of the lesions. Leakage caused local darkening of NIR, presumably originating from increased light-scattering and absorbance by fluid accumulation and sub-cellular structure alterations

    The spectral, spatial and contrast sensitivity of human polarization pattern perception

    Get PDF
    It is generally believed that humans perceive linear polarized light following its conversion into a luminance signal by diattenuating macular structures. Measures of polarization sensitivity may therefore allow a targeted assessment of macular function. Our aim here was to quantify psychophysical characteristics of human polarization perception using grating and optotype stimuli defined solely by their state of linear polarization. We show: (i) sensitivity to polarization patterns follows the spectral sensitivity of macular pigment; (ii) the change in sensitivity across the central field follows macular pigment density; (iii) polarization patterns are identifiable across a range of contrasts and scales, and can be resolved with an acuity of 15.4 cycles/degree (0.29 logMAR); and (iv) the human eye can discriminate between areas of linear polarization differing in electric field vector orientation by as little as 4.4°. These findings, which support the macular diattenuator model of polarization sensitivity, are unique for vertebrates and approach those of some invertebrates with a well-developed polarization sense. We conclude that this sensory modality extends beyond Haidinger's brushes to the recognition of quantifiable spatial polarization-modulated patterns. Furthermore, the macular origin and sensitivity of human polarization pattern perception makes it potentially suitable for the detection and quantification of macular dysfunction

    Lutein supplementation in retinitis pigmentosa: PC-based vision assessment in a randomized double-masked placebo-controlled clinical trial [NCT00029289]

    Get PDF
    BACKGROUND: There is no generally accepted medical or surgical treatment to stop the progressive course of retinitis pigmentosa. Previous studies have suggested lutein as a potential treatment with positive effects on macular pigment density. The objective of this study was to examine the effect of lutein supplementation on preservation of visual function in patients with retinitis pigmentosa (RP) METHODS: In a double-masked randomized placebo-controlled phase I/II clinical trial with a cross-over design, 34 adult patients with RP were randomized to two groups. One group, consisted of 16 participants, received lutein supplementation (10 mg/d for 12 wks followed by 30 mg/d) for the first 24 weeks and then placebo for the following 24 weeks, while the other group included 18 participants for whom placebo (24 weeks) was administered prior to lutein. Visual acuity, contrast sensitivity, and central visual field were measured at different illumination levels at baseline and every week using a PC-based test at home. RESULTS: For visual acuity (VA) at normal illumination level, treatment with lutein reduced logMAR, i.e. improved VA, but this effect was not statistically significant. The changes in normal (100%), low (4%), and very low (0.1%) illumination log CS were not statistically significant (p-values: 0.34, 0.23, and 0.32, respectively). Lutein had a statistically significant effect on visual field (p-value: 0.038) and this effect increased in the model assuming a 6-week delay in effect of lutein. Comparing the development of vision measures against the natural loss expected to occur over the course of 48 weeks, most measures showed reduced decline, and these reductions were significant for normal illumination VA and CS. CONCLUSION: These results suggest that lutein supplementation improves visual field and also might improve visual acuity slightly, although these results should be interpreted cautiously. As a combined phase I and II clinical trial, this study demonstrated the efficacy and safety of lutein supplementation

    Effect of lutein and antioxidant dietary supplementation on contrast sensitivity in age-related macular disease:A randomized controlled trial

    Get PDF
    Objective: The aim of the study is to determine the effect of lutein combined with vitamin and mineral supplementation on contrast sensitivity in people with age-related macular disease (ARMD). Design: A prospective, 9-month, double-masked randomized controlled trial. Setting: Aston University, Birmingham, UK and a UK optometric clinical practice. Subjects: Age-related maculopathy (ARM) and atrophic age-related macular degeneration (AMD) participants were randomized (using a random number generator) to either placebo (n = 10) or active (n=15) groups. Three of the placebo group and two of the active group dropped out. Interventions: The active group supplemented daily with 6 mg lutein combined with vitamins and minerals. The outcome measure was contrast sensitivity (CS) measured using the Pelli-Robson chart, for which the study had 80% power at the 5% significance level to detect a change of 0.3log units. Results: The CS score increased by 0.07 ± 0.07 and decreased by 0.02 ± 0.18 log units for the placebo and active groups, respectively. The difference between these values is not statistically significant (z = 0.903, P = 0.376). Conclusion: The results suggest that 6 mg of lutein supplementation in combination with other antioxidants is not beneficial for this group. Further work is required to establish optimum dosage levels

    Multimodal imaging of an RPGR carrier female

    No full text

    Reference values for anterior chamber morphometrics with swept-source optical coherence tomography in a Caucasian population

    No full text
    Hellen CS R&ouml;mkens, Henny JM Beckers, Jan SAG Schouten, Tos TJM Berendschot, Carroll AB Webers Department of Ophthalmology, Maastricht University Medical Center+, Maastricht, the Netherlands Purpose: The aim of this study is to generate reference values for anterior chamber morphometrics to facilitate the interpretation of anterior chamber images acquired with swept-source optical coherence tomography (SS-OCT) in a Caucasian population.Materials and methods: Non-glaucomatous Caucasian subjects, who were newly referred to the outpatient department of the University Eye Clinic Maastricht UMC+, were asked to undergo anterior segment assessment with SS-OCT imaging prior to routine eye examination (including visual acuity and refractive error measurements, Goldmann applanation tonometry, slit lamp examination and funduscopy).Results: A total of 647 Caucasian subjects, aged 40&ndash;80 years, were included. Mean age (&plusmn;&nbsp;standard deviation) was 61.7&plusmn;10.3 years, and 294 were male (45%). Mean refractive error was -0.63&plusmn;3.17 D. OCT images and measurements were obtained in all cases. The mean temporal trabecular iris angle at 500 &micro;m (TIA500) was 27.04&deg;&plusmn;12.04&deg;, the mean nasal TIA500 was 27.43&deg;&plusmn;11.75&deg;, the mean anterior chamber depth (ACD) was 2.75&plusmn;0.39 mm and the mean lens vault (LV) was 0.44&plusmn;0.30 mm. A smaller temporal TIA500, shallower ACD and higher LV were found in female and hyperopic subjects.Conclusion: Reference values for anterior chamber morphometrics in Caucasians were generated, quantified and presented. These values offer tools for the interpretation of anterior segment images of Caucasians and differentiation between presumed mechanisms of angle closure. Keywords: reference value, anterior chamber, optical coherence tomography, Caucasian&nbsp

    Decreased fixation stability of the preferred retinal location in juvenile macular degeneration.

    No full text
    Macular degeneration is the main cause for diminished visual acuity in the elderly. The juvenile form of macular degeneration has equally detrimental consequences on foveal vision. To compensate for loss of foveal vision most patients with macular degeneration adopt an eccentric preferred retinal location that takes over tasks normally performed by the healthy fovea. It is unclear however, whether the preferred retinal locus also develops properties typical for foveal vision. Here, we investigated whether the fixation characteristics of the preferred retinal locus resemble those of the healthy fovea. For this purpose, we used the fixation-offset paradigm and tracked eye-position using a high spatial and temporal resolution infrared eye-tracker. The fixation-offset paradigm measures release from fixation under different fixation conditions and has been shown useful to distinguish between foveal and non-foveal fixation. We measured eye-movements in nine healthy age-matched controls and five patients with juvenile macular degeneration. In addition, we performed a simulation with the same task in a group of five healthy controls. Our results show that the preferred retinal locus does not adopt a foveal type of fixation but instead drifts further away from its original fixation and has overall increased fixation instability. Furthermore, the fixation instability is most pronounced in low frequency eye-movements representing a slow drift from fixation. We argue that the increased fixation instability cannot be attributed to fixation under an unnatural angle. Instead, diminished visual acuity in the periphery causes reduced oculomotor control and results in increased fixation instability
    corecore