7 research outputs found
Phase and amplitude measurement for the SPIRAL2 accelerator
International audienceThe SPIRAL2 project is composed of an accelerator and a radioactive beam section. Radioactive ions beams (RIBs) will be accelerated by the current cyclotron CIME and sent at GANIL experimental areas. The accelerator, with a RFQ and a superconducting Linac, will accelerate 5 mA deuterons up to 40MeV and 1 mA heavy ions up to 14.5 MeV/u. A new electronic device has been evaluated at GANIL to measure phase and amplitude of pick-up signals. The principle consists of directly digitizing pulses by under-sampling. Phase and amplitude of different harmonics are then calculated with a FPGA by an I/Q method. Tests and first results of a prototype are shown and presented as well as future evolutions
Irradiation control of the "SPIRAL" target by measuring the ion beam intensity via a fast current transformer
International audienceIn order to obtain a more precise control on the irradiation of the targets of the "SPIRAL" installation, a new criterion of safety must be respected. To control this latter, an AQ system has been put in operation and more specifically a new device has been set up in order to measure the ion beam intensity and to calculate the number of particules per second. This value can then be integrated over time. This device consists of two Fast Current Transformers integrated in a mechanical unit placed in a vacuum chamber. These sensors reproduce the image of the pulsed beam at 10MHz and we take from the amplified signal of each sensor, the amplitude of the 2nd harmonic. Each one of these amplitudes is detected by a Lock-in Amplifier, which is acquired via a real time industrial controller. The intensity is calculated by the Fourier series relation between the amplitude of the 2nd harmonic and the average intensity. These equipments can be remotely tested by integrating a test turn on the sensors. They are redundant. The accuracy of measurement is estimated taking into account the variation of beam, of the environment and of the installatio
THI safety system
International audienceFor several years, GANIL has been allowed to reach a maximum beam power of six kilowatts (400W in normal mode) thanks to the THI system (High Intensity Transport System). Three modes of running are necessary to accelerate a THI beam ("Injector" mode, "tuning" mode and "surveillance" mode). The "surveillance" mode requires a safety system to protect equipment against beam losses. Inside cyclotrons, diagnostics measure beam-loss currents at the injection and extraction devices. Along beam lines, diaphragms measure beam-loss currents at the input and output of dipoles. Current transformers are used for beam transmission measurements through beam lines and the cyclotrons. The safety system controls beam losses and quickly cuts the beam with a chopper if losses exceed thresholds. These thresholds can be seen and changed by software
SPIRAL 2 injector diagnostics
International audienceThe future SPIRAL2 facility will be composed of a multi-beam driver accelerator (5 mA/40 MeV deuterons, 5 mA /14.5 MeV/u heavy ions) and a dedicated building for the production of radioactive ion beams (RIBs). RIBs will be accelerated by the existing cyclotron CIME for the post acceleration and sent to GANIL's experimental areas. The injector constituted by an ion source a deuteron/proton source a L.E.B.T. and a M.E.B.T. lines and a room temperature R.F.Q. will produces, transports and accelerates beams up to an energy of 0.75 MeV/u. An Intermediate Test Bench (B.T.I.) is being built to commission the SPIRAL2 injector through the first rebuncher of the M.E.B.T. line in a first step and the last rebuncher in a second step. The B.T.I. is designed to perform a wide variety of measurements and functions and to go more deeply in the understanding of the behaviour of diagnostics under high average intensity beam operations. A superconducting LINAC equipped with two types of cavity will allow reaching 20 MeV/u for deuterons beam. This paper describes injector diagnostic developments and gives information about the current status
Mesures d'énergie par temps de vol sur l'accélérateur SPIRAL2.
CDROMNational audienceLe projet SPIRAL2 consiste à construire un accélérateur et une section de production de faisceaux exotiques, ces faisceaux seront envoyés dans les salles de physique du GANIL. Un système de mesure d'énergie du faisceau est prévu à la sortie du RFQ pendant le commissioning de l'accélérateur. Un autre système devrait être installé dans la ligne LHE à la sortie du Linac. Ce document décrit le design mécanique des sondes pick-up, la simulation des signaux issus de ces pick-up. L'étude et les tests d'un nouveau système électronique de mesure de l'énergie par temps de vol seront aussi présentés
GANIL High Intensity Transport Safety System
International audienceIFor several years, GANIL has been allowed to reach a maximum beam power of six kilowatts (400W in normal mode) thanks to the THI system (High Intensity Transport System). Three modes of running are necessary to accelerate a THI beam ("Injector" mode, "tuning" mode and "surveillance" mode. The "surveillance" mode requires a safety system to protect equipments against beam losses. Inside cyclotrons, diagnostics measure beam losses current at the injection and extraction devices. Along beam lines, diaphragms measure beam losses current at the input and output of dipoles. Current transformers are used for the beam transmission measurements through beam lines and cyclotrons. The safety system controls beam losses and quickly reduces the beam intensity with a chopper if some losses overshoot thresholds. These thresholds can be monitored by software