10 research outputs found

    Evaluation of a rapid colorimetric field test to assess the effective life of long-lasting insecticide-treated mosquito nets in the Lao PDR

    Get PDF
    BACKGROUND: Malaria morbidity and mortality have been significantly reduced through the proper use of insecticide-treated mosquito nets, but the extra protection afforded by the insecticide diminishes over time. The insecticide depletion rates vary according to location where wash frequency and wear are influenced by cultural habits as well as the availability of water. Monitoring of available insecticides on the net surface is essential for determining the effective life of the net. Therefore, a rapid and inexpensive colorimetric field test for cyanopyrethroids (Cyanopyrethroid Field Test or CFT) was used to measure surface levels of deltamethrin on insecticide-coated polyester nets (PowerNets™) in rural Lao PDR over a two-year period. METHODS: Net surface levels of deltamethrin were measured by wiping the net with filter paper and measuring the adsorbed deltamethrin using the CFT. A relationship between surface levels of deltamethrin and whole net levels was established by comparing results of the CFT with whole levels assayed by high-performance liquid chromatography (HPLC). An effective deltamethrin surface concentration (EC80) was determined by comparing mosquito mortality (WHO Cone Test) with CFT and HPLC results. Five positions (roof to bottom) on each of 23 matched nets were assayed for deltamethrin surface levels at 6, 12, and 24 months. Mosquito mortality assays (WHO Cone Tests) were performed on a subset of eleven 24-month old nets and compared with the proportion of failed nets as predicted by the CFT. RESULTS: At six months, the nets retained about 80% of the baseline (new net) levels of deltamethrin with no significant differences between net positions. At 12 months, ~15-40%, and at 24 months <10% of deltamethrin was retained on the nets, with significant differences appearing between positions. Results from the CFT show that 93% of the nets failed (deltamethrin surface levels </= EC80) at 24 months. This value is in agreement with 91% failure as determined by the WHO Cone Test on a subset of 11 nets. The CFT results show that 50% of the nets from Laos failed at 12 months of normal use. CONCLUSION: The CFT is a useful and accurate indicator of net efficacy and may be substituted for mosquito bioassays

    A random survey of the prevalence of falsified and substandard antibiotics in the Lao PDR

    No full text
    OBJECTIVES:In 2012, a stratified random survey, using mystery shoppers, was conducted to investigate the availability and quality of antibiotics sold to patients in the private sector in five southern provinces of the Lao People's Democratic Republic (Laos). METHODS:A total of 147 outlets were sampled in 10 districts. The active pharmaceutical ingredient (API) content measurements for 909 samples, including nine APIs (amoxicillin, ampicillin, ceftriaxone, ciprofloxacin, doxycycline, ofloxacin, sulfamethoxazole, tetracycline and trimethoprim), were determined using HPLC. RESULTS:All the analysed samples contained the stated API and we found no evidence for falsification. All except one sample had all the units tested with %API values between 75% and 125% of the content stated on the label. However, we identified the presence of substandard antibiotics: 19.6% (201/1025) of samples had their units outside the 90%-110% content of the label claim and 60.2% (617/1025) of the samples had units outside of the International Pharmacopoeia uniformity of content limit range. Amoxicillin had a high number of samples [67.1% (151)] with units above the limit range, followed by ciprofloxacin [58.8% (10)] and ofloxacin [57.4% (39)]. Ceftriaxone, trimethoprim and sulfamethoxazole had the highest number of samples with low API content: 57.1% (4), 51.6% (64) and 34.7% (43), respectively. Significant differences in %API were found between stated countries of manufacture and stated manufacturers. CONCLUSIONS:With the global threat of antimicrobial resistance to patient outcomes, greater understanding of the role of poor-quality antibiotics is needed. Substandard antibiotics will have reduced therapeutic efficacy, impacting public health and control of bacterial infections

    A random survey of the prevalence of falsified and substandard antibiotics in the Lao PDR

    No full text
    Objectives In 2012, a stratified random survey, using mystery shoppers, was conducted to investigate the availability and quality of antibiotics sold to patients in the private sector in five southern provinces of the Lao People’s Democratic Republic (Laos). Methods A total of 147 outlets were sampled in 10 districts. The active pharmaceutical ingredient (API) content measurements for 909 samples, including nine APIs (amoxicillin, ampicillin, ceftriaxone, ciprofloxacin, doxycycline, ofloxacin, sulfamethoxazole, tetracycline and trimethoprim), were determined using HPLC. Results All the analysed samples contained the stated API and we found no evidence for falsification. All except one sample had all the units tested with %API values between 75% and 125% of the content stated on the label. However, we identified the presence of substandard antibiotics: 19.6% (201/1025) of samples had their units outside the 90%–110% content of the label claim and 18.3% (188/1025) of the samples had units outside the International Pharmacopoeia/United States Pharmacopoeia assay (percentage of label claim) specifications. Trimethoprim had a high number of samples [51.6% (64)] with units below the limit range, followed by ceftriaxone [42.9% (3)] and sulfamethoxazole [34.7% (43)]. Doxycycline, ofloxacin and ciprofloxacin had the highest number of samples with high API content: 43.7% (38), 14.7% (10) and 11.8% (2), respectively. Significant differences in %API were found between stated countries of manufacture and stated manufacturers. Conclusions With the global threat of antimicrobial resistance on patient outcomes, greater understanding of the role of poor-quality antibiotics is needed. Substandard antibiotics will have reduced therapeutic efficacy, impacting public health and control of bacterial infections

    A random survey of the prevalence of falsified and substandard antibiotics in the Lao PDR

    No full text
    OBJECTIVES:In 2012, a stratified random survey, using mystery shoppers, was conducted to investigate the availability and quality of antibiotics sold to patients in the private sector in five southern provinces of the Lao People's Democratic Republic (Laos). METHODS:A total of 147 outlets were sampled in 10 districts. The active pharmaceutical ingredient (API) content measurements for 909 samples, including nine APIs (amoxicillin, ampicillin, ceftriaxone, ciprofloxacin, doxycycline, ofloxacin, sulfamethoxazole, tetracycline and trimethoprim), were determined using HPLC. RESULTS:All the analysed samples contained the stated API and we found no evidence for falsification. All except one sample had all the units tested with %API values between 75% and 125% of the content stated on the label. However, we identified the presence of substandard antibiotics: 19.6% (201/1025) of samples had their units outside the 90%-110% content of the label claim and 60.2% (617/1025) of the samples had units outside of the International Pharmacopoeia uniformity of content limit range. Amoxicillin had a high number of samples [67.1% (151)] with units above the limit range, followed by ciprofloxacin [58.8% (10)] and ofloxacin [57.4% (39)]. Ceftriaxone, trimethoprim and sulfamethoxazole had the highest number of samples with low API content: 57.1% (4), 51.6% (64) and 34.7% (43), respectively. Significant differences in %API were found between stated countries of manufacture and stated manufacturers. CONCLUSIONS:With the global threat of antimicrobial resistance to patient outcomes, greater understanding of the role of poor-quality antibiotics is needed. Substandard antibiotics will have reduced therapeutic efficacy, impacting public health and control of bacterial infections

    Quality of artemisinin-based combination formulations for malaria treatment: Prevalence and risk Factors for poor quality medicines in public facilities and private sector drug outlets in Enugu, Nigeria

    Get PDF
    Background Artemisinin-based combination therapies are recommended by the World Health Organisation (WHO) as first-line treatment for Plasmodium falciparum malaria, yet medication must be of good quality for efficacious treatment. A recent meta-analysis reported 35% (796/2,296) of antimalarial drug samples from 21 Sub-Saharan African countries, purchased from outlets predominantly using convenience sampling, failed chemical content analysis. We used three sampling strategies to purchase artemisinin-containing antimalarials (ACAs) in Enugu metropolis, Nigeria, and compared the resulting quality estimates. Methods ACAs were purchased using three sampling approaches - convenience, mystery clients and overt, within a defined area and sampling frame in Enugu metropolis. The active pharmaceutical ingredients were assessed using high-performance liquid chromatography and confirmed by mass spectrometry at three independent laboratories. Results were expressed as percentage of APIs stated on the packaging and used to categorise each sample as acceptable quality, substandard, degraded, or falsified. Results Content analysis of 3024 samples purchased from 421 outlets using convenience (n=200), mystery (n=1,919) and overt (n=905) approaches, showed overall 90.8% ACAs to be of acceptable quality, 6.8% substandard, 1.3% degraded and 1.2% falsified. Convenience sampling yielded a significantly higher prevalence of poor quality ACAs, but was not evident by the mystery and overt sampling strategies both of which yielded results that were comparable between each other. Artesunate (n=135; 4 falsified) and dihydroartemisinin (n=14) monotherapy tablets, not recommended by WHO, were also identified. Conclusion Randomised sampling identified fewer falsified ACAs than previously reported by convenience approaches. Our findings emphasise the need for specific consideration to be given to sampling frame and sampling approach if representative information on drug quality is to be obtained
    corecore