285 research outputs found

    Multimodal nanoparticle imaging agents: Design and applications

    Get PDF
    Molecular imaging, where the location of molecules or nanoscale constructs can be tracked in the body to report on disease or biochemical processes, is rapidly expanding to include combined modality or multimodal imaging. No single imaging technique can offer the optimum combination of properties (e.g. resolution, sensitivity, cost, availability). The rapid technological advances in hardware to scan patients, and software to process and fuse images, are pushing the boundaries of novel medical imaging approaches, and hand-in-hand with this is the requirement for advanced and specific multimodal imaging agents. These agents can be detected using a selection from radioisotope, magnetic resonance and optical imaging, among others. Nanoparticles offer great scope in this area as they lend themselves, via facile modification procedures, to act as multifunctional constructs. They have relevance as therapeutics and drug delivery agents that can be tracked by molecular imaging techniques with the particular development of applications in optically guided surgery and as radiosensitizers. There has been a huge amount of research work to produce nanoconstructs for imaging, and the parameters for successful clinical translation and validation of therapeutic applications are now becoming much better understood. It is an exciting time of progress for these agents as their potential is closer to being realized with translation into the clinic. The coming 5–10 years will be critical, as we will see if the predicted improvement in clinical outcomes becomes a reality. Some of the latest advances in combination modality agents are selected and the progression pathway to clinical trials analysed. This article is part of the themed issue ‘Challenges for chemistry in molecular imaging’

    Synthesis, structures and cytotoxicity studies of p-sulfonatocalix[4]arene lanthanide complexes

    Get PDF
    A number of p-sulfonatocalix[4]arene complexes of the lanthanides (Tb, Gd, and Eu) have been prepared, some in the presence of tetraazamacrocycle 1,4,7,10-tetraazacyclododecane-1,4,7-triacetic acid (DO3A), and fully characterised. Crystal structure determinations reveal lanthanide coordination at the sulfonate group, bridging several calixarene units, giving coordination polymers. All complexes in this study have been determined to be relatively non-toxic using in vitro cell assays with CC₅₀ values in the range 30–170 μM

    Positron detection in silica monoliths for miniaturised quality control of PET radiotracers

    Get PDF
    We demonstrate the use of the miniaturised Medipix positron sensor for detection of the clinical PET radiotracer, [⁶⁸Ga]gallium-citrate, on a silica-based monolith, towards microfluidic quality control. The system achieved a far superior signal-to-noise ratio compared to conventional sodium iodide-based radio-HPLC detection and allowed real-time visualisation of positrons in the monolith

    How does iron interact with sporopollenin exine capsules? An X-ray absorption study including microfocus XANES and XRF imaging

    Get PDF
    Sporopollenin exine capsules (SECs) derived from plant spores and pollen grains have been proposed as adsorption, remediation and drug delivery agents. Despite many studies there is scant structural data available. This X-ray absorption investigation represents the first direct structural data on the interaction of metals with SECs and allows elucidation of their structure–property relationships. Fe K-edge XANES and EXAFS data have shown that the iron local environment in SECs (derived from Lycopodium clavatum) reacted with aqueous ferric chloride solutions is similar to that of ferrihydrite (FeOOH) and by implication ferritin. Fe Kα XRF micro-focus experiments show that there is a poor correlation between the iron distribution and the underlying SEC structure indicating that the SEC is coated in the FeOOH material. In contrast, the Fe Kα XRF micro-focus experiments on SECs reacted with aqueous ferrous chloride solutions show that there is a very high correlation between the iron distribution and the SEC structure, indicating a much more specific form of interaction of the iron with the SEC surface functional groups. Fe K-edge XANES and EXAFS data show that the FeII can be easily oxidised to give a structure similar to, but not identical to that in the FeIII case, and that even if anaerobic conditions are used there is still partial oxidation to FeIII

    Development of PDT/PET theranostics: synthesis and biological evaluation of an ¹⁸F-radiolabeled water soluble porphyrin

    Get PDF
    Synthesis of the first water-soluble porphyrin radiolabeled with fluorine-18 is described: a new molecular theranostic agent which integrates the therapeutic selectivity of photodynamic therapy (PDT) with the imaging efficacy of positron emission tomography (PET). Generation of the theranostic was carried out through the conjugation of a cationic water-soluble porphyrin bearing an azide functionality to a fluorine-18 radiolabeled prosthetic bearing an alkyne functionality through click conjugation, with excellent yields obtained in both cold and hot synthesis. Biological evaluation of the synthesized structures shows the first example of an 18 F-radiolabeled porphyrin retaining photocytotoxicity following radiolabeling and demonstrable conjugate uptake and potential application as a radiotracer in vivo. The promising results gained from biological evaluation demonstrate the potential of this structure as a clinically relevant theranostic agent, offering exciting possibilities for the simultaneous imaging and photodynamic treatment of tumors

    Monolith-based68Ga processing: A new strategy for purification to facilitate direct radiolabelling methods

    Get PDF
    The post-processing of68Ga generator eluate by means of a novel high capacity cation-exchange silica monolith column has been validated in this work. Quantitative release of a purified68Ga solution in high concentration can be achieved using weak acidic solutions which can be directly used for chelator or conjugate labelling in an injectable form with improved radiochemical characteristics. The system has the potential to be incorporated in a flow based microfluidic system for dose-on-demand radiotracer synthesis

    MRI and PET/MRI in hematologic malignancies

    Get PDF
    The role of MRI differs considerably between the three main groups of hematological malignancies: lymphoma, leukemia, and myeloma. In myeloma, whole-body MRI (WB-MRI) is recognized as a highly sensitive test for the assessment of myeloma, and is also endorsed by clinical guidelines, especially for detection and staging. In lymphoma, WB-MRI is presently not recommended, and merely serves as an alternative technique to the current standard imaging test, [18F]FDG-PET/CT, especially in pediatric patients. Even for lymphomas with variable FDG avidity, such as extranodal mucosa-associated lymphoid tissue lymphoma (MALT), contrast-enhanced computed tomography (CT), but not WB-MRI, is presently recommended, despite the high sensitivity of diffusion-weighted MRI and its ability to capture treatment response that has been reported in the literature. In leukemia, neither MRI nor any other cross-sectional imaging test (including positron emission tomography [PET]) is currently recommended outside of clinical trials. This review article discusses current clinical applications as well as the main research topics for MRI, as well as PET/MRI, in the field of hematological malignancies, with a focus on functional MRI techniques such as diffusion-weighted imaging and dynamic contrast-enhanced MRI, on the one hand, and novel, non-FDG PET imaging probes such as the CXCR4 radiotracer [68Ga]Ga-Pentixafor and the amino acid radiotracer [11C]methionine, on the other hand. Level of Evidence: 5. Technical Efficacy Stage: 3

    Synthesis, structure, and cytotoxicity studies of oxidovanadium(IV and V) complexes bearing chelating phenolates

    Get PDF
    The interaction of [VO(acac)2] with 2,6-bis(hydroxymethyl)-4-methylphenol (L1H3) or 6,6/-methylenebis(4-tert-butyl-2-(hydroxymethyl)phenol) (L2H4) in refluxing toluene afforded, following work-up in ethanol, the complexes [VOL1]2 (1) and {[VO(acac)(HOEt)](VO)L2]}2 (2), respectively. Use of 4-[3,5-bis(2-hydroxyphenyl)-1,2,4-triazol-1-yl]benzoic acid (L3H2) or 4-[3,5-bis(2-hydroxyphenyl)-1,2,4-triazol-1-yl]benzosulfonic acid (L4H2) with [VOCl3] in refluxing acetonitrile, followed by methanol and THF work-up, afforded the complexes [Et3NH][VO(OMe)L3]2 (3) and [Et3NH][VO(OMe)L4]2 (4), respectively. The interaction of [VOSO4] and L3H2 in refluxing acetonitrile afforded, with extraction into methanol, the complex [VO(OMe)L3]2 (5). The molecular structures of 2, 3 and 5 have been determined; the structure of 1 has been reported previously. The complexes in this study have been determined to be of low toxicity using in vitro cell assays with 50% cytotoxicity values (CC50) values in the range 56 – 126 µM
    corecore