59 research outputs found

    Power standard based on a high precision power-factor meter

    Get PDF
    PostprintA high-precision power-factor meter, based on zero crossing detectors, is proposed. The influence of the distortion in the input signals is analyzed and low pass filters proposed to prevent this error source. This system is proposed as a new power standard meter, based on the measurement of voltage, current and power factor

    Error evaluation of thermistor linearizing circuits

    Get PDF
    PostprintA simple designing method for linearizing circuits, based on one resistor, is presented. The errors caused by this circuit are calculated, considering the temperature range and the thermistor parameters. These errors are used as a basis for comparing the quality of active linearizing circuits. In many cases, complex circuits have similar errors to single resistor linearizing circuits. It is shown that the exponential approximation is one of the most important error sources. The authors propose to use more precise models. The relationship between the parameters of the exponential model and those of other models is discussed

    Comparación de patrones eléctricos en tensión continua mediante un divisor 10:1

    Get PDF
    En este trabajo se presenta un divisor resistivo auto-calibrable para relacionar los niveles de 1 V y 10 V de fuentes patrones de tensión continua (pilas patrones,fuentes Zener, sistemas Josephson). El sistema está basado en un divisor formado por 10 resistores iguales, en el cual se mide la caída de tensión en cada resistor individualmente, y la caída total. La relación entre la caída total y el promedio de las caídas individuales es, teóricamente, 10:1. Este sistema de medida sólo requiere del propio divisor y de un multímetro de 8½ dígitos, como elementos auxiliares. La incertidumbre obtenida en mediciones usando este divisor está en el orden de 1××10-7

    Un nuevo método para la protección diferencial de transformadores

    Get PDF
    Se presenta un nuevo método de detección de fallas internas en transformadores, basado en la medición de la energía consumida por el transformador. Este método detecta cortocircuitos de muy pocas espiras, aún durante el transitorio de irrupción o trabajado en régimen de sobre excitación. Por otro lado, no es afectado por la operación de conmutadores de relación de transformación bajo carga, tal como sucede en los relés diferenciales de corriente comunmente usados

    Patrones de resistencia en corriente alterna basados en resistores calculables

    Get PDF
    Se describe en el presente trabajo el diseño y construcción de resistores calculables coaxiales con valores de 140 O y 1000 O, para ser usados como patrones de resistencia en corriente alterna. Sus comportamientos calculados son evaluados mediante técnicas de simulación (Microcap) y ensayos de sus respuestas al escalón. Con estos parámetros se obtiene el error en magnitud y fase para una frecuencia determinada

    Evaluation of low-frequency voltage dividers, using the step response

    Get PDF
    PostprintA method to characterize the behavior of low frequency voltage dividers, based on the step response, is presented. Amplitude errors and phase displacements can be evaluated, in an absolute way, without any auxiliary standard divider

    Compensación de errores en transformadores de corriente usados en redes de alta tensión

    Get PDF
    Se describe una técnica para compensar los errores de transformadores de medida. Se muestra un ejemplo para transformadores instalados dentro de interruptores en redes de 150 kV. Errores de relación iniciales en el orden de 4% y de fase alrededor de 20 min se redujeron a 0.1% y 6 min después de la compensación

    Intercomparación multilateral de potencia eléctrica, entre los Laboratorios Nacionales de Alemania, Argentina, Brasil y Uruguay

    Get PDF
    Se presentan en este trabajo los resultados de la intercomparación en Potencia Eléctrica, entre los Laboratorios Nacionales de Alemania: Physikalisch – Technischen Bundesanstalt (PTB), Argentina: Instituto Nacional de Tecnología Industrial (INTI), Brasil: Instituto Nacional de Metrología, Normalizaçao e Qualidade Industrial (INMETRO) y Uruguay: Usinas y Trasmisiones Eléctricas (UTE), llevada a cabo durante 2004. El elemento utilizado como instrumento viajero fue un patrón de potencia perteneciente al PTB. Los resultados muestran valores compatibles para todos los laboratorios participantes, teniendo en cuenta los valores de desvío como las incertidumbres declaradas
    corecore