7,947 research outputs found
The signature of dissipation in the mass-size relation: are bulges simply spheroids wrapped in a disc?
The relation between the stellar mass and size of a galaxy's structural
subcomponents, such as discs and spheroids, is a powerful way to understand the
processes involved in their formation. Using very large catalogues of
photometric bulge+disc structural decompositions and stellar masses from the
Sloan Digital Sky Survey Data Release Seven, we carefully define two large
subsamples of spheroids in a quantitative manner such that both samples share
similar characteristics with one important exception: the 'bulges' are embedded
in a disc and the 'pure spheroids' are galaxies with a single structural
component. Our bulge and pure spheroid subsample sizes are 76,012 and 171,243
respectively. Above a stellar mass of ~ M, the mass-size
relations of both subsamples are parallel to one another and are close to lines
of constant surface mass density. However, the relations are offset by a factor
of 1.4, which may be explained by the dominance of dissipation in their
formation processes. Whereas the size-mass relation of bulges in discs is
consistent with gas-rich mergers, pure spheroids appear to have been formed via
a combination of 'dry' and 'wet' mergers.Comment: Accepted for publication in MNRAS, 6 pages, 3 figure
The infrared imaging spectrograph (IRIS) for TMT: sensitivities and simulations
We present sensitivity estimates for point and resolved astronomical sources
for the current design of the InfraRed Imaging Spectrograph (IRIS) on the
future Thirty Meter Telescope (TMT). IRIS, with TMT's adaptive optics system,
will achieve unprecedented point source sensitivities in the near-infrared
(0.84 - 2.45 {\mu}m) when compared to systems on current 8-10m ground based
telescopes. The IRIS imager, in 5 hours of total integration, will be able to
perform a few percent photometry on 26 - 29 magnitude (AB) point sources in the
near-infrared broadband filters (Z, Y, J, H, K). The integral field
spectrograph, with a range of scales and filters, will achieve good
signal-to-noise on 22 - 26 magnitude (AB) point sources with a spectral
resolution of R=4,000 in 5 hours of total integration time. We also present
simulated 3D IRIS data of resolved high-redshift star forming galaxies (1 < z <
5), illustrating the extraordinary potential of this instrument to probe the
dynamics, assembly, and chemical abundances of galaxies in the early universe.
With its finest spatial scales, IRIS will be able to study luminous, massive,
high-redshift star forming galaxies (star formation rates ~ 10 - 100 M yr-1) at
~100 pc resolution. Utilizing the coarsest spatial scales, IRIS will be able to
observe fainter, less massive high-redshift galaxies, with integrated star
formation rates less than 1 M yr-1, yielding a factor of 3 to 10 gain in
sensitivity compared to current integral field spectrographs. The combination
of both fine and coarse spatial scales with the diffraction-limit of the TMT
will significantly advance our understanding of early galaxy formation
processes and their subsequent evolution into presentday galaxies.Comment: SPIE Astronomical Instrumentation 201
A Search for Nitrogen Enriched Quasars in the Sloan Digital Sky Survey Early Data Release
A search for nitrogen-rich quasars in the Sloan Digital Sky Survey Early Data
Release (SDSS EDR) catalog has yielded 16 candidates, including five with very
prominent emission, but no cases with nitrogen emission as strong as in
Q0353-383. The quasar Q0353-383 has long been known to have extremely strong
nitrogen intercombination lines at lambda 1486 and lambda 1750 Angstroms,
implying an anomalously high nitrogen abundance of about 15 times solar. It is
still the only one of its kind known. A preliminary search through the EDR
using the observed property of the weak C IV emission seen in Q0353-383
resulted in a sample of 23 objects with unusual emission or absorption-line
properties, including one very luminous redshift 2.5 star-forming galaxy. We
present descriptions, preliminary emission-line measurements, and spectra for
all the objects discussed here.Comment: 20 pages, 5 figures, submitted to AJ; final refereed versio
The Infrared Imaging Spectrograph (IRIS) for TMT: the atmospheric dispersion corrector
We present a conceptual design for the atmospheric dispersion corrector (ADC)
for TMT's Infrared Imaging Spectrograph (IRIS). The severe requirements of this
ADC are reviewed, as are limitations to observing caused by uncorrectable
atmospheric effects. The requirement of residual dispersion less than 1
milliarcsecond can be met with certain glass combinations. The design decisions
are discussed and the performance of the design ADC is described. Alternative
options and their performance tradeoffs are also presented.Comment: SPIE Astronomical Instrumentation 201
The Infrared Imaging Spectrograph (IRIS) for TMT: Volume phase holographic grating performance testing and discussion
Maximizing the grating efficiency is a key goal for the first light
instrument IRIS (Infrared Imaging Spectrograph) currently being designed to
sample the diffraction limit of the TMT (Thirty Meter Telescope). Volume Phase
Holographic (VPH) gratings have been shown to offer extremely high efficiencies
that approach 100% for high line frequencies (i.e., 600 to 6000l/mm), which has
been applicable for astronomical optical spectrographs. However, VPH gratings
have been less exploited in the near-infrared, particularly for gratings that
have lower line frequencies. Given their potential to offer high throughputs
and low scattered light, VPH gratings are being explored for IRIS as a
potential dispersing element in the spectrograph. Our team has procured
near-infrared gratings from two separate vendors. We have two gratings with the
specifications needed for IRIS current design: 1.51-1.82{\mu}m (H-band) to
produce a spectral resolution of 4000 and 1.19- 1.37 {\mu}m (J-band) to produce
a spectral resolution of 8000. The center wavelengths for each grating are
1.629{\mu}m and 1.27{\mu}m, and the groove densities are 177l/mm and 440l/mm
for H-band R=4000 and J-band R=8000, respectively. We directly measure the
efficiencies in the lab and find that the peak efficiencies of these two types
of gratings are quite good with a peak efficiency of ~88% at the Bragg angle in
both TM and TE modes at H-band, and 90.23% in TM mode, 79.91% in TE mode at
J-band for the best vendor. We determine the drop in efficiency off the Bragg
angle, with a 20-23% decrease in efficiency at H-band when 2.5 degree deviation
from the Bragg angle, and 25%-28% decrease at J-band when 5{\deg} deviation
from the Bragg angle.Comment: Proceedings of the SPIE, 9147-33
A new species in the major malaria vector complex sheds light on reticulated species evolution
Complexes of closely related species provide key insights into the rapid and independent evolution of adaptive traits. Here, we described and studied Anopheles fontenillei sp.n., a new species in the Anopheles gambiae complex that we recently discovered in the forested areas of Gabon, Central Africa. Our analysis placed the new taxon in the phylogenetic tree of the An. gambiae complex, revealing important introgression events with other members of the complex. Particularly, we detected recent introgression, with Anopheles gambiae and Anopheles coluzzii, of genes directly involved in vectorial capacity. Moreover, genome analysis of the new species allowed us to clarify the evolutionary history of the 3La inversion. Overall, An. fontenillei sp.n. analysis improved our understanding of the relationship between species within the An. gambiae complex, and provided insight into the evolution of vectorial capacity traits that are relevant for the successful control of malaria in Africa
The infrared imaging spectrograph (IRIS) for TMT: spectrograph design
The Infra-Red Imaging Spectrograph (IRIS) is one of the three first light
instruments for the Thirty Meter Telescope (TMT) and is the only one to
directly sample the diffraction limit. The instrument consists of a parallel
imager and off-axis Integral Field Spectrograph (IFS) for optimum use of the
near infrared (0.84um-2.4um) Adaptive Optics corrected focal surface. We
present an overview of the IRIS spectrograph that is designed to probe a range
of scientific targets from the dynamics and morphology of high-z galaxies to
studying the atmospheres and surfaces of solar system objects, the latter
requiring a narrow field and high Strehl performance. The IRIS spectrograph is
a hybrid system consisting of two state of the art IFS technologies providing
four plate scales (4mas, 9mas, 25mas, 50mas spaxel sizes). We present the
design of the unique hybrid system that combines the power of a lenslet
spectrograph and image slicer spectrograph in a configuration where major
hardware is shared. The result is a powerful yet economical solution to what
would otherwise require two separate 30m-class instruments.Comment: 15 pages, 11 figure
Recommended from our members
Magnetic Resonance Imaging Pilot Study of Intravenous Glyburide in Traumatic Brain Injury.
Pre-clinical studies of traumatic brain injury (TBI) show that glyburide reduces edema and hemorrhagic progression of contusions. We conducted a small Phase II, three-institution, randomized placebo-controlled trial of subjects with TBI to assess the safety and efficacy of intravenous (IV) glyburide. Twenty-eight subjects were randomized and underwent a 72-h infusion of IV glyburide or placebo, beginning within 10 h of trauma. Of the 28 subjects, 25 had Glasgow Coma Scale (GCS) scores of 6-10, and 14 had contusions. There were no differences in adverse events (AEs) or severe adverse events (ASEs) between groups. The magnetic resonance imaging (MRI) percent change at 72-168 h from screening/baseline was compared between the glyburide and placebo groups. Analysis of contusions (7 per group) showed that lesion volumes (hemorrhage plus edema) increased 1036% with placebo versus 136% with glyburide (p = 0.15), and that hemorrhage volumes increased 11.6% with placebo but decreased 29.6% with glyburide (p = 0.62). Three diffusion MRI measures of edema were quantified: mean diffusivity (MD), free water (FW), and tissue MD (MDt), corresponding to overall, extracellular, and intracellular water, respectively. The percent change with time for each measure was compared in lesions (n = 14) versus uninjured white matter (n = 24) in subjects receiving placebo (n = 20) or glyburide (n = 18). For placebo, the percent change in lesions for all three measures was significantly different compared with uninjured white matter (analysis of variance [ANOVA], p < 0.02), consistent with worsening of edema in untreated contusions. In contrast, for glyburide, the percent change in lesions for all three measures was not significantly different compared with uninjured white matter. Further study of IV glyburide in contusion TBI is warranted
- …
