48 research outputs found

    Analysis of ground waters using the "Tsvet-3006" ion chromatograph

    Get PDF
    Examples are given of the use of "Tsvet-3006" ion chromatographs for routine analysis of ground waters for the anion and cation contents. In the analysis of anions by the two-column ion chromatography method, the use of separation columns with an inner diameter 4 mm rather than 6 mm permits the time for determination of anions to be shortened by more than a factor of 2 and thus reduced to 12-15 min. The efficiency of separation of anions is shown to improve and the labor in the analysis of waters to decrease by a factor of 2-3. © 1998 Plenum Publishing Corporation

    Modeling of Self-Assembled Peptide Nanotubes and Determination of Their Chirality Sign Based on Dipole Moment Calculations

    Full text link
    The chirality quantification is of great importance in structural biology, where the differ-ences in proteins twisting can provide essentially different physiological effects. However, this aspect of the chirality is still poorly studied for helix-like supramolecular structures. In this work, a method for chirality quantification based on the calculation of scalar triple products of dipole moments is suggested. As a model structure, self-assembled nanotubes of diphenylalanine (FF) made of L-and D-enantiomers were considered. The dipole moments of FF molecules were calculated using semi-empirical quantum-chemical method PM3 and the Amber force field method. The obtained results do not depend on the used simulation and calculation method, and show that the D-FF nanotubes are twisted tighter than L-FF. Moreover, the type of chirality of the helix-like nanotube is opposite to that of the initial individual molecule that is in line with the chirality alternation rule general for different levels of hierarchical organization of molecular systems. The proposed method can be applied to study other helix-like supramolecular structures. © 2021 by the authors. Licensee MDPI, Basel, Switzerland.Acknowledgments: The authors are grateful to the Russian Foundation for Basic Researches (RFBR): grants №№ 19–01–00519_A and 20-51-53014_GFEN_A. Part of this work (A.K.) was supported by the Ministry of Science and Higher Education of the Russian Federation (grant No. 075-15-2021-588). P.Z., S.K. and A.K. are grateful to the FCT project “BioPiezo”—PTDC/CTM−CTM/31679/2017 (CENTRO-01-0145-FEDER-031679) and to the project CICECO-Aveiro Institute of Materials, refs. UIDB/50011/2020 and UIDP/50011/2020, financed by national funds through the Portuguese Foundation for Science and Technology/MCTES. Part of this work was funded by national funds (OE), through FCT–Fundação para a Ciência e a Tecnologia, I.P., in the scope of the framework contract foreseen in the numbers 4, 5, and 6 of the article 23, of the Decree-Law 57/2016, of August 29, changed by Law 57/2017, of July 19. A.S. and E.M. are grateful to the the Interdisciplinary Scientific and Educational School of Moscow University “Fundamental and Applied Space Research”

    Modified carbon-containing electrodes in stripping voltammetry of metals

    Full text link

    Modified carbon-containing electrodes in stripping voltammetry of metals. Part II. Composite and microelectrodes

    Full text link

    Analysis of ground waters using the "Tsvet-3006" ion chromatograph

    Get PDF
    Examples are given of the use of "Tsvet-3006" ion chromatographs for routine analysis of ground waters for the anion and cation contents. In the analysis of anions by the two-column ion chromatography method, the use of separation columns with an inner diameter 4 mm rather than 6 mm permits the time for determination of anions to be shortened by more than a factor of 2 and thus reduced to 12-15 min. The efficiency of separation of anions is shown to improve and the labor in the analysis of waters to decrease by a factor of 2-3. © 1998 Plenum Publishing Corporation

    Analysis of ground waters using the "Tsvet-3006" ion chromatograph

    No full text
    Examples are given of the use of "Tsvet-3006" ion chromatographs for routine analysis of ground waters for the anion and cation contents. In the analysis of anions by the two-column ion chromatography method, the use of separation columns with an inner diameter 4 mm rather than 6 mm permits the time for determination of anions to be shortened by more than a factor of 2 and thus reduced to 12-15 min. The efficiency of separation of anions is shown to improve and the labor in the analysis of waters to decrease by a factor of 2-3. © 1998 Plenum Publishing Corporation
    corecore