8 research outputs found

    Dedicated plug based closure for large bore access -The MARVEL prospective registry

    Get PDF
    Objectives To study safety and performance of the MANTA Vascular closure device (VCD) under real world conditions in 10 centers. Background The MANTA is a novel plug-based device for large bore arteriotomy closure. Methods We included all eligible patients who underwent transfemoral large bore percutaneous procedures. Exclusion criteria were per operator's discretion and included severe calcification or marked tortuosity of the access vessel, presence of marked obesity/cachexia or a systolic blood pressure above 180 mmHg. The primary performance endpoint was time to hemostasis. Primary and secondary safety endpoints were major and minor access site related vascular complications up to 30 days, respectively. Vascular complications were adjudicated by an independent clinical event committee according to VARC-2 criteria. We performed multivariable logistic regression to estimate the effect of baseline and procedural characteristics on any and major vascular complications. Results Between February 2018 and July 2019 500 patients were enrolled undergoing Transcatheter aortic valve replacement (TAVR, N = 496), Balloon aortic valvuloplasty (BAV, N = 2), Mechanical circulatory support (MCS, N = 1) or Endovascular aneurysm repair (EVAR, N = 1). Mean age was 80.8 +/- 6.6 years with a median STS-score of 2.7 [IQR 2.0-4.3] %. MANTA access site complications were major in 20 (4%) and minor in 28 patients (5.6%). Median time to hemostasis was 50 [IQR 20-120] sec. Severe femoral artery calcification, scar presence in groin, longer procedure duration, female gender and history of hypertension were independent predictors for vascular complications. Conclusion In this study, MANTA appeared to be a safe and effective device for large bore access closure under real-world conditions.Peer reviewe

    MANTA versus ProGlide vascular closure devices in transfemoral transcatheter aortic valve implantation

    No full text
    Abstract Background: The MANTA system is a novel vascular closure device (VCD) and its safety and efficacy were compared to the ProGlide VCD in patients undergoing transfemoral transcatheter aortic valve implantation (TAVI). Methods: This is a retrospective study including 222 patients who underwent transfemoral TAVI at three Finnish University Hospitals. The MANTA VCD was used in 107 patients and their outcome was compared with that of 115 patients in whom the arterial access was closed with the ProGlide VCD. Results: VARC-2 VCD failure occurred less frequently in the MANTA cohort (3.7% vs. 7.8%, p = 0.378), but the difference did not reach statistical significance. When adjusted for the introducer outer diameter, the MANTA cohort had similar rates of VARC-2 major vascular complications (9.3% vs. 12.2%, adjusted: p = 0.456), VARC-2 life-threatening/disabling bleeding (9.3% vs. 6.1%, adjusted: p = 0.296) and need of invasive treatment of bleeding (4.7% vs. 7.0%, adjusted: p = 0.416) compared to the ProGlide cohort. Additional VCDs were more frequently needed in the ProGlide cohort (58.3% vs. 1.9%, p < 0.0001). Conclusions: In patients undergoing transfemoral TAVI, the MANTA VCD showed a similar risk of VARC-2 vascular and bleeding complications compared to the ProGlide VCD, but it reduced significantly the need of additional VCDs for completion of hemostasis

    Comparison of survival of transfemoral transcatheter aortic valve implantation versus surgical aortic valve replacement for aortic stenosis in low-risk patients without coronary artery disease

    No full text
    Abstract Increasing data support transcatheter aortic valve implantation (TAVI) as a valid option over surgical aortic valve replacement (SAVR) in the treatment for severe aortic stenosis (AS) also in patients with low operative risk. However, limited data exist on the outcome of TAVI and SAVR in low-risk patients without coronary artery disease (CAD). The FinnValve registry included data on 6463 patients who underwent TAVI or SAVR with bioprosthesis between 2008 and 2017. Herein, we evaluated the outcome of low operative risk as defined by STS-PROM score &lt;3% and absence of CAD, previous stroke and other relevant co-morbidities. Only patients who underwent TAVI with third-generation prostheses and SAVR with Perimount Magna Ease or Trifecta prostheses were included in this analysis. The primary endpoints were 30-day and 3-year all-cause mortality. Overall, 1,006 patients (175 TAVI patients and 831 SAVR patients) met the inclusion criteria of this analysis. Propensity score matching resulted in 140 pairs with similar baseline characteristics. Among these matched pairs, 30-day mortality was 2.1% in both TAVI and SAVR cohorts (p = 1.00) and 3-year mortality was 17.0% after TAVI and 14.6% after SAVR (p = 0.805). Lower rates of bleeding and atrial fibrillation, and shorter hospital stay were observed after TAVI. The need of new permanent pacemaker implantation and the incidence of early stroke did not differ between groups. In conclusion, TAVI using third-generation prostheses achieved similar early and mid-term survival compared with SAVR in low-risk patients without CAD

    Dedicated plug based closure for large bore access –The MARVEL prospective registry

    No full text
    Objectives: To study safety and performance of the MANTA Vascular closure device (VCD) under real world conditions in 10 centers. Background: The MANTA is a novel plug-based device for large bore arteriotomy closure. Methods: We included all eligible patients who underwent transfemoral large bore percutaneous procedures. Exclusion criteria were per operator's discretion and included severe calcification or marked tortuosity of the access vessel, presence of marked obesity/cachexia or a systolic blood pressure above 180 mmHg. The primary performance endpoint was time to hemostasis. Primary and secondary safety endpoints were major and minor access site related vascular complications up to 30 days, respectively. Vascular complications were adjudicated by an independent clinical event committee according to VARC-2 criteria. We performed multivariable logistic regression to estimate the effect of baseline and procedural characteristics on any and major vascular complications. Results: Between February 2018 and July 2019 500 patients were enrolled undergoing Transcatheter aortic valve replacement (TAVR, N = 496), Balloon aortic valvuloplasty (BAV, N = 2), Mechanical circulatory support (MCS, N = 1) or Endovascular aneurysm repair (EVAR, N = 1). Mean age was 80.8 ± 6.6 years with a median STS-score of 2.7 [IQR 2.0–4.3] %. MANTA access site complications were major in 20 (4%) and minor in 28 patients (5.6%). Median time to hemostasis was 50 [IQR 20–120] sec. Severe femoral artery calcification, scar presence in groin, longer procedure duration, female gender and history of hypertension were independent predictors for vascular complications. Conclusion: In this study, MANTA appeared to be a safe and effective device for large bore access closure under real-world conditions

    Mid-term outcomes of Sapien 3 versus Perimount Magna Ease for treatment of severe aortic stenosis

    No full text
    Abstract Background: There is limited information on the longer-term outcome after transcatheter aortic valve replacement (TAVR) with new-generation prostheses compared to surgical aortic valve replacement (SAVR). The aim of this study was to compare the mid-term outcomes after TAVR with Sapien 3 and SAVR with Perimount Magna Ease bioprostheses for severe aortic stenosis. Methods: In a retrospective study, we included patients who underwent transfemoral TAVR with Sapien 3 or SAVR with Perimount Magna Ease bioprosthesis between January 2008 and October 2017 from the nationwide FinnValve registry. Propensity score matching was performed to adjust for differences in the baseline characteristics. The Kaplan-Meir method was used to estimate late mortality. Results: A total of 2000 patients were included (689 in the TAVR cohort and 1311 in the SAVR cohort). Propensity score matching resulted in 308 pairs (STS score, TAVR 3.5 ± 2.2% vs. SAVR 3.5 ± 2.8%, p = 0.918). In-hospital mortality was 3.6% after SAVR and 1.3% after TAVR (p = 0.092). Stroke, acute kidney injury, bleeding and atrial fibrillation were significantly more frequent after SAVR, but higher rate of vascular complications was observed after TAVR. The cumulative incidence of permanent pacemaker implantation at 4 years was 13.9% in the TAVR group and 6.9% in the SAVR group (p = 0.0004). At 4-years, all-cause mortality was 20.6% for SAVR and 25.9% for TAVR (p = 0.910). Four-year rates of coronary revascularization, prosthetic valve endocarditis and repeat aortic valve intervention were similar between matched cohorts. Conclusions: The Sapien 3 bioprosthesis achieves comparable midterm outcomes to a surgical bioprosthesis with proven durability such as the Perimount Magna Ease. However, the Sapien 3 bioprosthesis was associated with better early outcome

    Comparison of outcomes after transcatheter aortic valve replacement vs surgical aortic valve replacement among patients with aortic stenosis at low operative risk

    No full text
    Abstract Importance: Transcatheter aortic valve replacement (TAVR) has been shown to be a valid alternative to surgical aortic valve replacement (SAVR) in patients at high operative risk with severe aortic stenosis (AS). However, the evidence of the benefits and harms of TAVR in patients at low operative risk is still scarce. Objective: To compare the short-term and midterm outcomes after TAVR and SAVR in low-risk patients with AS. Design, Setting, and Participants: This retrospective comparative effectiveness cohort study used data from the Nationwide Finnish Registry of Transcatheter and Surgical Aortic Valve Replacement for Aortic Valve Stenosis of patients at low operative risk who underwent TAVR or SAVR with a bioprosthesis for severe AS from January 1, 2008, to November 30, 2017. Low operative risk was defined as a Society of Thoracic Surgeons Predicted Risk of Mortality score less than 3% without other comorbidities of clinical relevance. One-to-one propensity score matching was performed to adjust for baseline covariates between the TAVR and SAVR cohorts. Exposures: Primary TAVR or SAVR with a bioprosthesis for AS with or without associated coronary revascularization. Main Outcomes and Measures: The primary outcomes were 30-day and 3-year survival. Results: Overall, 2841 patients (mean [SD] age, 74.0 [6.2] years; 1560 [54.9%] men) fulfilled the inclusion criteria and were included in the analysis; TAVR was performed in 325 patients and SAVR in 2516 patients. Propensity score matching produced 304 pairs with similar baseline characteristics. Third-generation devices were used in 263 patients (86.5%) who underwent TAVR. Among these matched pairs, 30-day mortality was 1.3% after TAVR and 3.6% after SAVR (P = .12). Three-year survival was similar in the study cohorts (TAVR, 85.7%; SAVR, 87.7%; P = .45). Interaction tests found no differences in terms of 3-year survival between the study cohorts in patients younger than vs older than 80 years or in patients who received recent aortic valve prostheses vs those who did not. Conclusions and Relevance: Transcatheter aortic valve replacement using mostly third-generation devices achieved similar short- and mid-term survival compared with SAVR in low-risk patients. Further studies are needed to assess the long-term durability of TAVR prostheses before extending their use to low-risk patients

    Impact of the COVID-19 Pandemic on Global TAVR Activity:The COVID-TAVI Study

    No full text
    Background: The COVID-19 pandemic adversely affected health care systems. Patients in need of transcatheter aortic valve replacement (TAVR) are especially susceptible to treatment delays. Objectives: This study sought to evaluate the impact of the COVID-19 pandemic on global TAVR activity. Methods: This international registry reported monthly TAVR case volume in participating institutions prior to and during the COVID-19 pandemic (January 2018 to December 2021). Hospital-level information on public vs private, urban vs rural, and TAVR volume was collected, as was country-level information on socioeconomic status, COVID-19 incidence, and governmental public health responses. Results: We included 130 centers from 61 countries, including 65,980 TAVR procedures. The first and second pandemic waves were associated with a significant reduction of 15% (P &lt; 0.001) and 7% (P &lt; 0.001) in monthly TAVR case volume, respectively, compared with the prepandemic period. The third pandemic wave was not associated with reduced TAVR activity. A greater reduction in TAVR activity was observed in Africa (−52%; P = 0.001), Central-South America (−33%; P &lt; 0.001), and Asia (−29%; P &lt; 0.001). Private hospitals (P = 0.005), urban areas (P = 0.011), low-volume centers (P = 0.002), countries with lower development (P &lt; 0.001) and economic status (P &lt; 0.001), higher COVID-19 incidence (P &lt; 0.001), and more stringent public health restrictions (P &lt; 0.001) experienced a greater reduction in TAVR activity. Conclusions: TAVR procedural volume declined substantially during the first and second waves of the COVID-19 pandemic, especially in Africa, Central-South America, and Asia. National socioeconomic status, COVID-19 incidence, and public health responses were associated with treatment delays. This information should inform public health policy in case of future global health crises.</p
    corecore