170 research outputs found
Transcatheter aortic valve implantation in a 54-year-old patient with aggressive HIV.
We report a case of a 54-year-old patient who was denied surgical replacement for severe aortic stenosis because of complicated acquired immunodeficiency syndrome and who successfully underwent transcatheter aortic valve implantation at our institution
Cystatin C as a nmarker of renal function Immediately after liver transplantation
To verify whether cystatin C may be of some use as a renal function marker immediately after orthotopic liver transplantation (OLT), we compared serum cystatin C (S(Cyst)), serum creatinine (S(cr)), and creatinine clearance (C(cr)) levels with the glomerular filtration rate (GFR). On postoperative days 1, 3, 5, and 7, S(Cyst) and S(cr) was measured in simultaneously drawn blood samples, whereas C(cr) was calculated using a complete 24-hour urine collection. The GFR was determined on the same days by means of iohexol plasma clearance (I-GFR). The correlation between 1/S(Cyst) and I-GFR was stronger than that of 1/S(cr) or C(cr) (P< 0.01). In the case of moderate reductions in I-GFR (80-60 mL/minute/1.73 m), S(cr) remained within the normal range, whereas the increase in S(cyst) was beyond its upper limit; for I-GFR reductions to lower levels (59-40 mL/minute/1.73 m), S(cr) increased slightly, whereas S(cyst) was twice its upper normal limit. When we isolated all of the I-GFR values on days 3, 5, and 7 that were > or = 30% lower than that recorded on the first postoperative day, S(Cyst)(P< 0.0001) and S(cr) (P< 0.01) levels were increased, whereas C(cr) remained unchanged (P = 0.09). Receiver operating characteristic (ROC) area-under-the-curve analysis showed that the diagnostic accuracy of S(cyst) was better than that of S(cr) and C(cr). S(cyst) levels of 1.4, 1.7, and 2.2 mg/L respectively predicted I-GFR levels of 80, 60, and 40 mL/minute/1.73 m. In conclusion, cystatin C is a reliable marker of renal function during the immediate post-OLT period, especially when the goal is to identify moderate changes in GFR
The Neochord Procedure After Failed Surgical Mitral Valve Repair
Surgical mitral valve reintervention is associated with significant morbidity and mortality, and repeat repair is not always feasible. We examine the clinical outcomes of the NeoChord procedure after failed conventional mitral valve repair. A total of 312 patients were treated with the NeoChord repair procedure between January 2014 and December 2018 at 5 European centers. Clinical and echocardiographic data were reviewed to identify patients who had a prior surgical mitral valve repair procedure. The primary endpoint (Patient Success) was a composite of placement of at least 2 neochordae and end-procedure mitral valve regurgitation (MR) †mild, freedom from death, stroke, structural or functional procedure failure (MR > moderate), procedure or device-related unplanned procedures, cardiac-related rehospitalization, or worsening NYHA functional class at 1 and 2-year FU. Fifteen (15) patients were identified who required reoperation for failed surgical mitral valve repair. Mean time-to-reoperation was 2.7 years (2.2-6.1). Median intensive care unit stay was 24 hours and median hospitalization time was 7 days (6-8). No in-hospital deaths were observed. At discharge, mitral regurgitation was †mild in 13 patients (86.7%). Patient success and freedom from more than mild MR were 92.3 ± 7.4% and 83.9 ± 10.4% at 1 and 2-year follow-up respectively. One high-risk patient presented with severe recurrent MR and died during surgical reintervention due to an acute aortic dissection. Selected patients can be successfully treated with the NeoChord procedure after failed surgical mitral valve repair. These results support a wider adoption of the NeoChord procedure as a first-line minimally invasive, alternative therapy to treat failed mitral valve repair
Outcome of liver transplantation with grafts from brain-dead donors treated with dual hypothermic oxygenated machine perfusion, with particular reference to elderly donors
Prompted by the utilization of extended criteria donors, dual hypothermic oxygenated machine perfusion (DâHOPE) was introduced in liver transplantation to improve preservation. When donors after neurological determination of death (DBD) are used, DâHOPE effect on graft outcomes is unclear. To assess DâHOPE value in this setting and to identify ideal scenarios for its use, data on primary adult liver transplant recipients from January 2014 to April 2021 were analyzed using inverse probability of treatment weighting, comparing outcomes of DâHOPEâtreated grafts (n = 121) with those preserved by static cold storage (n = 723). Endâischemic DâHOPE was systematically applied since November 2017 based on donor and recipient characteristics and transplant logistics. DâHOPE use was associated with a significant reduction of early allograft failure (OR: 0.24; 0.83; p = .024), grade â„3 complications (OR: 0.57; p = .046), comprehensive complication index (â7.20 points; p = .003), and improved patient and graft survival. These results were confirmed in the subset of elderly donors (>75âyearâold). Although DâHOPE did not reduce the incidence of biliary complications, its use was associated with a reduced severity of ischemic cholangiopathy. In conclusion, DâHOPE improves postoperative outcomes and reduces early allograft loss in extended criteria DBD grafts
- âŠ