685 research outputs found
Comparing the TiOblast and Osseospeed surfaces. Histomorphometric and histological analysis in humans
The aim of the present study was to compare two implant surfaces, the TiOblast (Astra Tech) surface, manufactured by blasting the surface and already present in literature and the Osseospeed (Astra Tech) surface, manufactured by blasting and treating the surface with fluoride ions and recently launched onto the market with the modified surfaces of the latest generation. This study is part of a more extensive research project whose protocol required the insertion of 10 couples of implants; thus in the present discussion partial data are being taken into consideration, with an eye at collecting more data in the future, regarding both microscopy and histomorphometric histological analysis on 5 couples of implants. The purpose of the study is to investigate how the modified surfaces of the latest generation can guarantee a greater osseointegration both from a qualitative and quantitative level compared to the surfaces presently used and that they may represent the first example of "bioactivity", that is, an active interaction with the processes of new bone formation and tissue healing
Noise thermometry applied to thermoelectric measurements in InAs nanowires
We apply noise thermometry to characterize charge and thermoelectric
transport in single InAs nanowires (NWs) at a bath temperature of 4.2 K. Shot
noise measurements identify elastic diffusive transport in our NWs with
negligible electron-phonon interaction. This enables us to set up a measurement
of the diffusion thermopower. Unlike in previous approaches, we make use of a
primary electronic noise thermometry to calibrate a thermal bias across the NW.
In particular, this enables us to apply a contact heating scheme, which is much
more efficient in creating the thermal bias as compared to conventional
substrate heating. The measured thermoelectric Seebeck coefficient exhibits
strong mesoscopic fluctuations in dependence on the back-gate voltage that is
used to tune the NW carrier density. We analyze the transport and
thermoelectric data in terms of approximate Mott's thermopower relation and to
evaluate a gate-voltage to Fermi energy conversion factor
Local noise in a diffusive conductor
The control and measurement of local non-equilibrium configurations is of
utmost importance in applications on energy harvesting, thermoelectrics and
heat management in nano-electronics. This challenging task can be achieved with
the help of various local probes, prominent examples including superconducting
or quantum dot based tunnel junctions, classical and quantum resistors, and
Raman thermography. Beyond time-averaged properties, valuable information can
also be gained from spontaneous fluctuations of current (noise). From these
perspective, however, a fundamental constraint is set by current conservation,
which makes noise a characteristic of the whole conductor, rather than some
part of it. Here we demonstrate how to remove this obstacle and pick up a local
noise temperature of a current biased diffusive conductor with the help of a
miniature noise probe. This approach is virtually noninvasive and extends
primary local measurements towards strongly non-equilibrium regimes.Comment: minor revision, accepted in Scientific Report
Ka-band (32-GHz) performance of 70-meter antennas in the Deep Space Network
Two models are provided of the Deep Space Network (DSN) 70 m antenna performance at Ka-band (32 GHz) and, for comparison purposes, one at X-band (8.4 GHz). The baseline 70 m model represents expected X-band and Ka-band performance at the end of the currently ongoing 64 m to 70 m mechanical upgrade. The improved 70 m model represents two sets of Ka-band performance estimates (the X-band performance will not change) based on two separately developed improvement schemes: the first scheme, a mechanical approach, reduces tolerances of the panels and their settings, the reflector structure and subreflector, and the pointing and tracking system. The second, an electronic/mechanical approach, uses an array feed scheme to compensate fo lack of antenna stiffness, and improves panel settings using microwave holographic measuring techniques. Results are preliminary, due to remaining technical and cost uncertainties. However, there do not appear to be any serious difficulties in upgrading the baseline DSN 70 m antenna network to operate efficiently in an improved configuration at 32 GHz (Ka-band). This upgrade can be achieved by a conventional mechanical upgrade or by a mechanical/electronic combination. An electronically compensated array feed system is technically feasible, although it needs to be modeled and demonstrated. Similarly, the mechanical upgrade requires the development and demonstration of panel actuators, sensors, and an optical surveying system
The DICE calibration project: design, characterization, and first results
We describe the design, operation, and first results of a photometric
calibration project, called DICE (Direct Illumination Calibration Experiment),
aiming at achieving precise instrumental calibration of optical telescopes. The
heart of DICE is an illumination device composed of 24 narrow-spectrum,
high-intensity, light-emitting diodes (LED) chosen to cover the
ultraviolet-to-near-infrared spectral range. It implements a point-like source
placed at a finite distance from the telescope entrance pupil, yielding a flat
field illumination that covers the entire field of view of the imager. The
purpose of this system is to perform a lightweight routine monitoring of the
imager passbands with a precision better than 5 per-mil on the relative
passband normalisations and about 3{\AA} on the filter cutoff positions. The
light source is calibrated on a spectrophotometric bench. As our fundamental
metrology standard, we use a photodiode calibrated at NIST. The radiant
intensity of each beam is mapped, and spectra are measured for each LED. All
measurements are conducted at temperatures ranging from 0{\deg}C to 25{\deg}C
in order to study the temperature dependence of the system. The photometric and
spectroscopic measurements are combined into a model that predicts the spectral
intensity of the source as a function of temperature. We find that the
calibration beams are stable at the level -- after taking the slight
temperature dependence of the LED emission properties into account. We show
that the spectral intensity of the source can be characterised with a precision
of 3{\AA} in wavelength. In flux, we reach an accuracy of about 0.2-0.5%
depending on how we understand the off-diagonal terms of the error budget
affecting the calibration of the NIST photodiode. With a routine 60-mn
calibration program, the apparatus is able to constrain the passbands at the
targeted precision levels.Comment: 25 pages, 27 figures, accepted for publication in A&
Angiogenesis modifications related with cetuximab plus irinotecan as anticancer treatment in advanced colorectal cancer patients.
Introduction: Angiogenesis has been correlated with increased invasion and metastases in a variety of human
neoplasms. Inadequate inhibition of the growth of tumor microvessels by anticancer agents may result in treatment
failure, rated clinically as progressive or stable disease. We designed this trial to investigate the modification of the
vascular endothelial growth factor (VEGF) and interferon-c (IFN-c) in advanced colorectal cancer patients during
treatment with a weekly combination of cetuximab plus irinotecan.
Materials and methods: Forty-five metastatic colorectal cancer patients were prospectively evaluated for
circulating levels of VEGF and IFN-c during the treatment with cetuximab (initial dose of 400 mg/m2
, followed by
weekly infusions of 250 mg/m2
) plus weekly irinotecan (90 mg/m2
). The circulating levels of the cytokines were
assessed at the following time points: just before and at 1, 21, 50 and 92 days after the start of cetuximab plus
irinotecan treatment.
Results: Basal serum VEGF median levels were significantly decreased just at the first day (after the first treatment
infusion (P = 0.016). The VEGF persisted at the following time points reaching the highest statistical significance
92 days after the first infusion (P < 0.0001). On the contrary, IFN-c values showed a statistical significant increase one
day after the first infusion (P < 0.0001). This effect persisted 21 days after the treatment start (P = 0.001), but was no
more evident at the following time points. Moreover, a linear regression model with variance analysis showed
a significant negative correlation between VEGF and IFN-c values 1, 21 and 50 days after the treatment beginning
(P = 0.002, 0.001 and 0.047, respectively).
Conclusions: This study suggests that a cetuximab may induce a modulation of VEGF circulating levels.
The reduction of VEGF serum levels is a sudden and long lasting phenomenon. Moreover, in our study we
identified a IFN-c increase, even if the specific role of this behavior remains to be investigated
- …