13 research outputs found

    Identifying patients at risk: multi-centre comparison of HeartMate 3 and HeartWare left ventricular assist devices

    Get PDF
    Aims: Since the withdrawal of HeartWare (HVAD) from the global market, there is an ongoing discussion if and which patients require prophylactically exchange for a HeartMate 3 (HM3). Therefore, it is important to study outcome differences between HVAD and HM3 patients. Because centres differ in patient selection and standard of care, we performed a propensity score (PS)-based study including centres that implanted both devices and aimed to identify which HVAD patients are at highest risk. Methods and results: We performed an international multi-centre study (n = 1021) including centres that implanted HVAD and HM3. PS-matching was performed using clinical variables and the implanting centre. Survival and complications were compared. As a sensitivity analysis, PS-adjusted Cox regression was performed. Landmark analysis with conditional survival >2 years was conducted to evaluate long-term survival differences. To identify which HVAD patients may benefit from a HM3 upgrade, Cox regression using pre-operative variables and their interaction with device type was performed. Survival was significantly better for HM3 patients (P 2 years after implantation (P = 0.03). None of the pre-operative variable interactions in the Cox regression were significant. Conclusions: HM3 patients have a significantly better survival and a lower incidence of ischaemic strokes and pump thrombosis than HVAD patients. This survival difference persisted after 2 years of implantation. Additional research using post-operative variables is warranted to identify which HVAD patients need an upgrade to HM3 or expedited transplantation

    Impact of a surgical approach for implantation of durable left ventricular assist devices in patients on extracorporeal life support

    Get PDF
    Background The aim of this study was to evaluate the impact of the surgical approach on the postoperative outcome in patients who underwent left ventricular assist device (LVAD) implantation after having received veno-arterial extracorporeal life support (va-ECLS) using data from a European registry (ECLS-VAD). Five hundred and thirty-one patients were included. Methods A propensity score-adjusted outcome analysis was performed, resulting in 324 patients in the full sternotomy (FS) group and 39 in the less invasive surgery (LIS) group. Results The surgery lasted in median 236 min in the FS group versus 263 min in the LIS group (p = 0.289). The median chest tube output during the first 24 h was similar in both groups. Patients who underwent implantation with an FS required more blood products during the first 24 postoperative hours (median 16 vs. 12, p = 0.033). The incidence of revision due to bleeding was also higher (35.5 vs. 15.4%, p = 0.016). A temporary postoperative right ventricular assist device was necessary in 45.1 (FS) versus 23.1% (LIS) of patients, respectively (p = 0.067). No stroke occurred in the LIS group during the first 30 days after surgery (7.4% in the FS group). The incidence of stroke and of renal, hepatic, and respiratory failure during the follow-up was similar in both groups. The 30-day and one-year survival were similar in both groups. Conclusion LIS for implantation of a durable LVAD in patients on va-ECLS implanted for cardiogenic shock is associated with less revision due to bleeding, less administration of blood products and absence of perioperative stroke, with no impact on survival

    Awake Implementation of Extracorporeal Life Support in Refractory Cardiogenic Shock

    No full text
    Background and objectives: Extracorporeal life support (ECLS) is a widely accepted and effective strategy for use in patients presenting with refractory cardiogenic shock. Implantation in awake and non-intubated patients allows for optimized evaluation of further therapy options while avoiding potential side effects associated with the need for sedation and intubation. The aim of the study was the assessment of safety and feasibility of awake ECLS implementation and of outcomes in patients treated with this concept. Materials and Methods: We retrospectively reviewed the concept of awake ECLS implantation in 16 consecutive patients (mean age 58 ± 8 years; male: 88%; ischemic cardiomyopathy: 50%) from 02/2017 to 01/2021. Study endpoints were survival to weaning or bridging to durable support or organ replacement and development of end-organ function and hemodynamic parameters on ECLS. Results: Fourteen patients (88%) were able to be successfully transitioned to definite therapy options. ECLS support stabilized end-organ function, led to a decrease in mean lactate levels (5.3 ± 3.7 mmol/L at baseline to 1.9 ± 1.3 mmol/L 12 h after ECLS start; p = 0.01) and improved hemodynamics (median central venous pressure 20 ± 5 mmHg vs. 10 ± 2 mmHg, p = 0.001) over a median duration of two days (1–8 days IQR). Two patients (13%) died on ECLS support due to multi-organ dysfunction syndrome. Survival to discharge of initially successfully bridged or weaned patients was 64%. Conclusions: Awake ECLS implantation is feasible and safe with the key advantage of omitting or delaying general anesthesia and intubation, with their associated risks in cardiogenic-shock patients, facilitating further decision making

    Psoas Muscle Area Predicts Mortality after Left Ventricular Assist Device Implantation

    No full text
    Several risk scores and classifications are available to predict peri- and post-operative mortality of patients with end stage heart failure receiving Left Ventricular Assist Device (LVAD) therapy. Sarcopenia has been suggested as a sensitive predictor for post-operative mortality. We evaluated whether the psoas muscle area can predict mortality in patients undergoing LVAD implantation. The indexed psoas mean area (PMAi) was obtained by measuring the psoas muscle area at the superior endplate of the third lumbar vertebra correlated to body surface area of 106 adult patients undergoing LVAD implantation (Medtronic HVAD n = 41, Abbott HeartMate II n = 4, Abbott HeartMate 3 n = 61; mean age 65, IQR 12, 90.6% male; INTERMACS Level 1 24.5%; ischemic CMP 64.2%). Patients were divided in two groups: high/moderate and low muscle mass. The primary endpoint was 30-day mortality, assessed using a multivariate Cox proportional hazards model. Baseline characteristics did not differ between patients with high or moderate and low PMAi. Estimated survival calculated a significant higher 30-day mortality in patients with low PMAi (p = 0.04). Multivariable Cox proportional hazards regression analysis indicated low PMAi, history of previous cardiac surgery and levels of bilirubin as independent predictors of mortality in the first 30 days. In conclusion, indexed psoas muscle area predicts mortality after LVAD implantation and can be used as an additional tool for risk stratification

    Relevance of Neutrophil Neprilysin in Heart Failure

    No full text
    Significant expression of neprilysin (NEP) is found on neutrophils, which present the transmembrane integer form of the enzyme. This study aimed to investigate the relationship of neutrophil transmembrane neprilysin (mNEP) with disease severity, adverse remodeling, and outcome in HFrEF. In total, 228 HFrEF, 30 HFpEF patients, and 43 controls were enrolled. Neutrophil mNEP was measured by flow-cytometry. NEP activity in plasma and blood cells was determined for a subset of HFrEF patients using mass-spectrometry. Heart failure (HF) was characterized by reduced neutrophil mNEP compared to controls (p < 0.01). NEP activity on peripheral blood cells was almost 4-fold higher compared to plasma NEP activity (p = 0.031) and correlated with neutrophil mNEP (p = 0.006). Lower neutrophil mNEP was associated with increasing disease severity and markers of adverse remodeling. Higher neutrophil mNEP was associated with reduced risk for mortality, total cardiovascular hospitalizations, and the composite endpoint of both (p < 0.01 for all). This is the first report describing a significant role of neutrophil mNEP in HFrEF. The biological relevance of neutrophil mNEP and exact effects of angiotensin-converting-enzyme inhibitors (ARNi) at the neutrophil site have to be determined. However, the results may suggest early initiation of ARNi already in less severe HF disease, where effects of NEP inhibition may be more pronounced

    Validation of Intrinsic Left Ventricular Assist Device Data Tracking Algorithm for Early Recognition of Centrifugal Flow Pump Thrombosis

    No full text
    Advanced stage heart failure patients can benefit from the unloading effects of an implantable left ventricular assist device. Despite best clinical practice, LVADs are associated with adverse events, such as pump thrombosis (PT). An adaptive algorithm alerting when an individual’s appropriate levels in pump power uptake are exceeded, such as in the case of PT, can improve therapy of patients implanted with a centrifugal LVAD. We retrospectively studied 75 patients implanted with a centrifugal LVAD in a single center. A previously optimized adaptive pump power-tracking algorithm was compared to clinical best practice and clinically available constant threshold algorithms. Algorithm performances were analyzed in a PT group (n = 16 patients with 30 PT events) and a thoroughly selected control group (n = 59 patients, 34.7 patient years of LVAD data). Comparison of the adaptive power-tracking algorithm with the best performing constant threshold algorithm resulted in sensitivity of 83.3% vs. 86.7% and specificity of 98.9% vs. 95.3%, respectively. The power-tracking algorithm produced one false positive detection every 11.6 patient years and early warnings with a median of 3.6 days prior to PT diagnosis. In conclusion, a retrospective single-center validation study with real-world patient data demonstrated advantageous application of a power-tracking algorithm into LVAD systems and clinical practice

    When Nothing Goes Right: Risk Factors and Biomarkers of Right Heart Failure after Left Ventricular Assist Device Implantation

    No full text
    Right heart failure (RHF) is a severe complication after left ventricular assist device (LVAD) implantation. The aim of this study was to analyze the incidence, risk factors, and biomarkers for late RHF including the possible superiority of the device and implantation method. This retrospective, single-center study included patients who underwent LVAD implantation between 2014 and 2018. Primary outcome was freedom from RHF over one-year after LVAD implantation; secondary outcomes included pre- and postoperative risk factors and biomarkers for RHF. Of the 145 consecutive patients (HeartMate 3/HVAD: n = 70/75; female: 13.8%), thirty-one patients (21.4%) suffered RHF after a mean LVAD support of median (IQR) 105 (118) days. LVAD implantation method (less invasive: 46.7% vs. 35.1%, p = 0.29) did not differ significantly in patients with or without RHF, whereas the incidence of RHF was lower in HeartMate 3 vs. HVAD patients (12.9% vs. 29.3%, p = 0.016). Multivariate Cox proportional hazard analysis identified HVAD (HR 4.61, 95% CI 1.12–18.98; p = 0.03), early post-op heart rate (HR 0.96, 95% CI 0.93–0.99; p = 0.02), and central venous pressure (CVP) (HR 1.21, 95% CI 1.05–1.39; p = 0.01) as independent risk factors for RHF, but no association of RHF with increased all-cause mortality (HR 1.00, 95% CI 0.99–1.01; p = 0.50) was found. To conclude, HVAD use, lower heart rate, and higher CVP early post-op were independent risk factors for RHF following LVAD implantation
    corecore