783 research outputs found

    Severe Lumbar Disability Is Associated With Decreased Psoas Cross-Sectional Area in Degenerative Spondylolisthesis

    Get PDF
    Study Design: Retrospective cohort. Objectives: Alterations in lumbar paraspinal muscle cross-sectional area (CSA) may correlate with lumbar pathology. The purpose of this study was to compare paraspinal CSA in patients with degenerative spondylolisthesis and severe lumbar disability to those with mild or moderate lumbar disability, as determined by the Oswestry Disability Index (ODI). Methods: We retrospectively reviewed the medical records of 101 patients undergoing lumbar fusion for degenerative spondylolisthesis. Patients were divided into ODI score ≤40 (mild/moderate disability, MMD) and ODI score \u3e40 (severe disability, SD) groups. The total CSA of the psoas and paraspinal muscles were measured on preoperative magnetic resonance imaging (MRI). Results: There were 37 patients in the SD group and 64 in the MMD group. Average age and body mass index were similar between groups. For the paraspinal muscles, we were unable to demonstrate any significant differences in total CSA between the groups. Psoas muscle CSA was significantly decreased in the SD group compared with the MMD group (1010.08 vs 1178.6 mm2, P =.041). Multivariate analysis found that psoas CSA in the upper quartile was significantly protective against severe disability (P =.013). Conclusions: We found that patients with severe lumbar disability had no significant differences in posterior lumbar paraspinal CSA when compared with those with mild/moderate disability. However, severely disabled patients had significantly decreased psoas CSA, and larger psoas CSA was strongly protective against severe disability, suggestive of a potential association with psoas atrophy and worsening severity of lumbar pathology. © The Author(s) 2018

    Phase and amplitude correction for multi-echo water-fat separation with bipolar acquisitions

    Get PDF
    Purpose: To address phase and amplitude errors for multi-point water-fat separation with bipolar acquisitions, which efficiently collect all echoes with alternating read-out gradient polarities in one repetition. Materials and Methods: With the bipolar acquisitions, eddy currents and other system nonidealities can induce inconsistent phase errors between echoes, disrupting water-fat separation. Previous studies have addressed phase correction in the read-out direction. However, the bipolar acquisitions may be subject to spatially high order phase errors as well as an amplitude modulation in the read-out direction. A method to correct for the 2D phase and amplitude errors is introduced. Low resolution reference data with reversed gradient polarities are collected. From the pair of low-resolution data collected with opposite gradient polarities, the two-dimensional phase errors are estimated and corrected. The pair of data are then combined for water-fat separation. Results: We demonstrate that the proposed method can effectively remove the high order errors with phantom and in vivo experiments, including obliquely oriented scans. Conclusion: For bipolar multi-echo acquisitions, uniform water-fat separation can be achieved by removing high order phase errors with the proposed method. © 2010 Wiley-Liss, Inc

    Degenerate dispersive equations arising in the study of magma dynamics

    Full text link
    An outstanding problem in Earth science is understanding the method of transport of magma in the Earth's mantle. Models for this process, transport in a viscously deformable porous media, give rise to scalar degenerate, dispersive, nonlinear wave equations. We establish a general local well-posedness for a physical class of data (roughly H1H^1) via fixed point methods. The strategy requires positive lower bounds on the solution. This is extended to global existence for a subset of possible nonlinearities by making use of certain conservation laws associated with the equations. Furthermore, we construct a Lyapunov energy functional, which is locally convex about the uniform state, and prove (global in time) nonlinear dynamic stability of the uniform state for any choice of nonlinearity. We compare the dynamics to that of other problems and discuss open questions concerning a larger range of nonlinearities, for which we conjecture global existence.Comment: 27 Pages, 7 figures are not present in this version. See http://www.columbia.edu/~grs2103/ for a PDF with figures. Submitted to Nonlinearit

    Noise analysis for 3-point chemical shift-based water-fat separation with spectral modeling of fat

    Get PDF
    Purpose: To model the theoretical signal-to-noise ratio (SNR) behavior of 3-point chemical shift-based water-fat separation, using spectral modeling of fat, with experimental validation for spin-echo and gradient-echo imaging. The echo combination that achieves the best SNR performance for a given spectral model of fat was also investigated. Materials and Methods: Cramér-Rao bound analysis was used to calculate the best possible SNR performance for a given echo combination. Experimental validation in a fatwater phantom was performed and compared with theory. In vivo scans were performed to compare fat separation with and with out spectral modeling of fat. Results: Theoretical SNR calculations for methods that include spectral modeling of fat agree closely with experimental SNR measurements. Spectral modeling of fat more accurately separates fat and water signals, with only a slight decrease in the SNR performance of the water-only image, although with a relatively large decrease in the fat SNR performance. Conclusion: The optimal echo combination that provides the best SNR performance for water using spectral modeling of fat is very similar to previous optimizations that modeled fat as a single peak. Therefore, the optimal echo spacing commonly used for single fat peak models is adequate for most applications that use spectral modeling of fat. © 2010 Wiley-Liss, Inc

    Microscopic theory of the pseudogap and Peierls transition in quasi-one-dimensional materials

    Get PDF
    The problem of deriving from microscopic theory a Ginzburg-Landau free energy functional to describe the Peierls or charge-density-wave transition in quasi-one-dimensional materials is considered. Particular attention is given to how the thermal lattice motion affects the electronic states. Near the transition temperature the thermal lattice motion produces a pseudogap in the density of states at the Fermi level. Perturbation theory diverges and the traditional quasi-particle or Fermi liquid picture breaks down. The pseudogap causes a significant modification of the coefficients in the Ginzburg-Landau functional from their values in the rigid lattice approximation, which neglects the effect of the thermal lattice motion. To appear in Physical Review B.Comment: 21 pages, RevTeX, 5 figures in uuencoded compressed tar fil

    A novel methodology for in vivo endoscopic phenotyping of colorectal cancer based on real-time analysis of the mucosal lipidome: a prospective observational study of the iKnife

    Get PDF
    Background: This pilot study assessed the diagnostic accuracy of rapid evaporative ionization mass spectrometry (REIMS) in colorectal cancer (CRC) and colonic adenomas. Methods: Patients undergoing elective surgical resection for CRC were recruited at St. Mary’s Hospital London and The Royal Marsden Hospital, UK. Ex vivo analysis was performed using a standard electrosurgery handpiece with aspiration of the electrosurgical aerosol to a Xevo G2-S iKnife QTof mass spectrometer (Waters Corporation). Histological examination was performed for validation purposes. Multivariate analysis was performed using principal component analysis and linear discriminant analysis in Matlab 2015a (Mathworks, Natick, MA). A modified REIMS endoscopic snare was developed (Medwork) and used prospectively in five patients to assess its feasibility during hot snare polypectomy. Results: Twenty-eight patients were recruited (12 males, median age 71, range 35–89). REIMS was able to reliably distinguish between cancer and normal adjacent mucosa (NAM) (AUC 0.96) and between NAM and adenoma (AUC 0.99). It had an overall accuracy of 94.4 % for the detection of cancer versus adenoma and an adenoma sensitivity of 78.6 % and specificity of 97.3 % (AUC 0.99) versus cancer. Long-chain phosphatidylserines (e.g., PS 22:0) and bacterial phosphatidylglycerols were over-expressed on cancer samples, while NAM was defined by raised plasmalogens and triacylglycerols expression and adenomas demonstrated an over-expression of ceramides. REIMS was able to classify samples according to tumor differentiation, tumor budding, lymphovascular invasion, extramural vascular invasion and lymph node micrometastases (AUC’s 0.88, 0.87, 0.83, 0.81 and 0.81, respectively). During endoscopic deployment, colonoscopic REIMS was able to detect target lipid species such as ceramides during hot snare polypectomy. Conclusion: REIMS demonstrates high diagnostic accuracy for tumor type and for established histological features of poor prognostic outcome in CRC based on a multivariate analysis of the mucosal lipidome. REIMS could augment endoscopic and imaging technologies for precision phenotyping of colorectal cancer

    Report on an all-sky LIGO search for periodic gravitational waves in the S4 data

    Full text link
    We report on an all-sky search with the LIGO detectors for periodic gravitational waves in the frequency range 50-1000 Hz and having a negative frequency time derivative with magnitude between zero and 10810^{-8} Hz/s. Data from the fourth LIGO science run have been used in this search. Three different semi-coherent methods of summing strain power were applied. Observing no evidence for periodic gravitational radiation, we report upper limits on strain amplitude and interpret these limits to constrain radiation from rotating neutron stars.Comment: 5 pages, 1 figure, presented at Amaldi7, Sydney (July 2007

    Searching for stochastic gravitational-wave background with the co-located LIGO interferometers

    Full text link
    This paper presents techniques developed by the LIGO Scientific Collaboration to search for the stochastic gravitational-wave background using the co-located pair of LIGO interferometers at Hanford, WA. We use correlations between interferometers and environment monitoring instruments, as well as time-shifts between two interferometers (described here for the first time) to identify correlated noise from non-gravitational sources. We veto particularly noisy frequency bands and assess the level of residual non-gravitational coupling that exists in the surviving data.Comment: Proceedings paper from the 7th Edoardo Amaldi Conference on Gravitational Waves, held in Sydney, Australia from 8-14 July 2007. Accepted to J. Phys.: Conf. Se

    Independent estimation of T\u3csup\u3e*\u3c/sup\u3e2 for water and fat for improved accuracy of fat quantification

    Get PDF
    Noninvasive biomarkers of intracellular accumulation of fat within the liver (hepatic steatosis) are urgently needed for detection and quantitative grading of nonalcoholic fatty liver disease, the most common cause of chronic liver disease in the United States. Accurate quantification of fat with MRI is challenging due the presence of several confounding factors, including T z.ast;2 decay. The specific purpose of this work is to quantify the impact of Tz.ast;2decay and develop a multiexponential Tz.ast;2 correction method for improved accuracy of fat quantification, relaxing assumptions made by previous T z.ast;2 correction methods. A modified Gauss-Newton algorithm is used to estimate the Tz.ast;2 for water and fat independently. Improved quantification of fat is demonstrated, with independent estimation of Tz.ast;2 for water and fat using phantom experiments. The tradeoffs in algorithm stability and accuracy between multiexponential and single exponential techniques are discussed. © 2010 Wiley-Liss, Inc
    corecore