4 research outputs found

    Analysis of fit on implants of chrome cobalt versus titanium frameworks made by cad / cam milling

    Get PDF
    This study analyzed the degree of passive and vertical fit achieved in frameworks using either cobalt-chromium (Co-Cr) or titanium (Ti) implant-supported fixed partial dentures ( FPDs) fabricated with a CAD/CAM milling technique. 33 3-unit FDPs, 17 of Co-Cr metal alloy (test group) and 16 of Ti (control group), were manufactured with two implants by copy milled technology. Optical microscopy was used to measure passive fit (PF) and vertical fit (VF) in all frameworks. The PF was evaluated by using the Single Screw test and the VF with the screws tightened at 20 Ncm. Descriptive and inferential analysis were performed to evaluate statistically significant differences in the tested groups for each fit. Brunner-Langer models were applied to assess potential material and implant area effects on the measurements. An ANOVA test was performed to estimate both main effects and interactions. The average PF values in the screwed implant were 4.43 ± 0.52 µm for Ti and 5.50 ± 1.61 µm for Co-Cr and in the non-screwed implant 5.59 ± 1.32 µm in the group Ti and 6.25 ± 1.55 µm the Co-Cr group. In this last implant, it was not observed statistically significant differences between both types of alloy (p = 0.178) nor between zones. Ti control group exhibited a significantly better VF than Co-Cr (p = 0.046) in the screwed implant but there were no differences in the implant not screwed. The VF in the non-screwed implant was better in lingual than in buccal zone. The PF and VF measurements observed in Co-Cr frameworks are clinically acceptable. 3-unit implant supported FPDs made with Co-Cr alloy using milling technique showed similar dimensional accuracy than those obtained with Ti

    Case report : vertical preparation protocol for veneers

    Get PDF
    The biologically oriented preparation technique (BOPT) consists of a vertical preparation of the tooth that involves a reduction to zero of the emergence anatomy, the creation of a new finish area, and immediate temporization, so that the gingiva is supp

    Telescopic crowns in adult case with lip and palate cleft : update on the etiology and management

    Get PDF
    Lip and palatal clefts are among the most important congenital craniofacial malformations to be taken into account in general dental practice, due to their high incidence and important repercussions upon the oral cavity. The underlying causes are genetic and fundamentally environmental, and the disorders manifest as early as in the embryonic period. Males are predominantly affected, with a 7:3 ratio versus females. Our patient, a 20-year-old male, presented the most common association, i.e., total unilateral hare lip with palatal cleft. A description is provided of the treatment for his dental problem, together with an update on the etiology and management of adults with malformations of this kind

    Valoración del comportamiento de supraestructuras fijas de 3 unidades atornilladas sobre implantes confeccionadas con CAD/CAM y con aleación de cobalto-cromo vs titanio. Un ensayo de fatiga

    No full text
    Tesis inédita presentada en la Universidad Europea de Madrid. Escuela de Doctorado e Investigación. Programa de Doctorado en Biomedicina y Ciencias de la SaludUE
    corecore