189 research outputs found

    The role of a conserved guanosine residue in the hammerhead-type RNA enzyme

    Get PDF
    AbstractWe have designed a hammerhead-type RNA system which consists of three RNA fagments for normal and modified complexes which contain a non-cleavable substrate with 2'-O-methylcytidine and a guanosine-to-inosine replaced enzyme. Examination of the RNA-cleaving activity and conformational properties of the complexes suggests that the 2-amino group of a conserved guanosine residue in the loop region plays an important role for maintaining both the activity and loop conformation

    Development of a frequency-detuned interferometer as a prototype experiment for next-generation gravitational-wave detectors

    Get PDF
    We report on our prototype experiment that uses a 4-m detuned resonant sideband extraction interferometer with suspended mirrors, which has almost the same configuration as the next-generation, gravitational-wave detectors. We have developed a new control scheme and have succeeded in the operation of such an interferometer with suspended mirrors for the first time ever as far as we know. We believe that this is the first such instrument that can see the radiation pressure signal enhancement, which can improve the sensitivity of next-generation gravitational-wave detectors

    Measurement of optical response of a detuned resonant sideband extraction gravitational wave detector

    Get PDF
    We report on the optical response of a suspended-mass detuned resonant sideband extraction (RSE) interferometer with power recycling. The purpose of the detuned RSE configuration is to manipulate and optimize the optical response of the interferometer to differential displacements (induced by gravitational waves) as a function of frequency, independently of other parameters of the interferometer. The design of our interferometer results in an optical gain with two peaks: an RSE optical resonance at around 4 kHz and a radiation pressure induced optical spring at around 41 Hz. We have developed a reliable procedure for acquiring lock and establishing the desired optical configuration. In this configuration, we have measured the optical response to differential displacement and found good agreement with predictions at both resonances and all other relevant frequencies. These results build confidence in both the theory and practical implementation of the more complex optical configuration being planned for Advanced LIGO

    Measurement of Optical Response of a Detuned Resonant Sideband Extraction Interferometer

    Full text link
    We report on the optical response of a suspended-mass detuned resonant sideband extraction (RSE) interferometer with power recycling. The purpose of the detuned RSE configuration is to manipulate and optimize the optical response of the interferometer to differential displacements (induced by gravitational waves) as a function of frequency, independently of other parameters of the interferometer. The design of our interferometer results in an optical gain with two peaks: an RSE optical resonance at around 4 kHz and a radiation pressure induced optical spring at around 41 Hz. We have developed a reliable procedure for acquiring lock and establishing the desired optical configuration. In this configuration, we have measured the optical response to differential displacement and found good agreement with predictions at both resonances and all other relevant frequencies. These results build confidence in both the theory and practical implementation of the more complex optical configuration being planned for Advanced LIGO.Comment: 6 pages, 4 figures, for submission to Phys Rev Letter

    2段生物処理法およびオゾン処理による皮革工場廃水混入下水からのCODと色度の削減

    Get PDF
    金沢大学理工研究域機械工学系Industrial wastewaters containing high concentrations of organic substances and ammonia nitrogen, such as leather industry wastewater, are sometimes treated by an activated sludge process in a sewage treatment plant. Such wastewaters tend to raise COD and color in the effluent of an activated sludge process. Refractory organic substance and nitrite build-up are the main causes of COD. It is difficult to reduce COD and color efficiently by the conventional activated sludge process.We studied a two-stage biological process combined an activated sludge process and a fixed-bed reactor to treat leather industry wastewater efficiently. And the use of ozone was studied to reduce COD and color.A two-stage biological process could promote nitrification reaction producing nitrate. COD originated from nitrite build-up was not observed. However, the two-stage biological process could not remove color.Ozone could reduce both COD and color in the effluent of an activated sludge process. However, nitrite build-up worsened the efficiency of ozone oxidation. In view of the economical point, it is important to prevent nitrite build-up in a biological process

    Multisensory information facilitates reaction speed by enlarging activity difference between superior colliculus hemispheres in rats

    Get PDF
    Animals can make faster behavioral responses to multisensory stimuli than to unisensory stimuli. The superior colliculus (SC), which receives multiple inputs from different sensory modalities, is considered to be involved in the initiation of motor responses. However, the mechanism by which multisensory information facilitates motor responses is not yet understood. Here, we demonstrate that multisensory information modulates competition among SC neurons to elicit faster responses. We conducted multiunit recordings from the SC of rats performing a two-alternative spatial discrimination task using auditory and/or visual stimuli. We found that a large population of SC neurons showed direction-selective activity before the onset of movement in response to the stimuli irrespective of stimulation modality. Trial-by-trial correlation analysis showed that the premovement activity of many SC neurons increased with faster reaction speed for the contraversive movement, whereas the premovement activity of another population of neurons decreased with faster reaction speed for the ipsiversive movement. When visual and auditory stimuli were presented simultaneously, the premovement activity of a population of neurons for the contraversive movement was enhanced, whereas the premovement activity of another population of neurons for the ipsiversive movement was depressed. Unilateral inactivation of SC using muscimol prolonged reaction times of contraversive movements, but it shortened those of ipsiversive movements. These findings suggest that the difference in activity between the SC hemispheres regulates the reaction speed of motor responses, and multisensory information enlarges the activity difference resulting in faster responses

    Sensing and control of the advanced LIGO optical configuration

    Get PDF
    The LIGO Laboratory 40m prototype interferometer at Caltech is being commissioned to prototype an optical configuration for Advanced LIGO. This optical configuration has to control five length degrees of freedom, and its control topology will be significantly more complicated than any other present interferometers. This paper explains the method of sensing, controls and lock acquisition

    担体投入法を用いた高濃度窒素含有下水からの窒素除去の効率化に関する検討事例

    Get PDF
    金沢大学理工研究域機械工学系日本下水道協会への転載許可申請済_2022.0

    ORP管理活性汚泥循環変法による高濃度窒素含有下水からの窒素除去

    Get PDF
    金沢大学理工研究域機械工学系日本下水道協会への転載許可申請済_2022.0

    Impact of baseline yellow plaque assessed by coronary angioscopy on vascular response after stent implantation

    Get PDF
    Tsujimura T., Mizote I., Ishihara T., et al. Impact of baseline yellow plaque assessed by coronary angioscopy on vascular response after stent implantation. Journal of Cardiology , (2024); https://doi.org/10.1016/j.jjcc.2024.04.004.Background: The relationship between baseline yellow plaque (YP) and vascular response after stent implantation has not been fully investigated. Methods: This was a sub-analysis of the Collaboration-1 study (multicenter, retrospective, observational study). A total of 88 lesions from 80 patients with chronic coronary syndrome who underwent percutaneous coronary intervention were analyzed. Optical coherence tomography (OCT) and coronary angioscopy (CAS) were serially performed immediately and 11 months after stent implantation. YP was defined as the stented segment with yellow or intensive yellow color assessed by CAS. Neoatherosclerosis was defined as a lipid or calcified neointima assessed by OCT. OCT and CAS findings at 11 months were compared between lesions with baseline YP (YP group) and lesions without baseline YP (Non-YP group). Results: Baseline YP was detected in 37 lesions (42 %). OCT findings at 11 months showed that the incidence of neoatherosclerosis was significantly higher in the YP group (11 % versus 0 %, p = 0.028) and mean neointimal thickness tended to be lower (104 ± 43 μm versus 120 ± 48 μm, p = 0.098). CAS findings at 11 months demonstrated that the dominant and minimum neointimal coverage grades were significantly lower (p = 0.049 and P = 0.026) and maximum yellow color grade was significantly higher (p < 0.001) in the YP group. Conclusions: Baseline YP affected the incidence of neoatherosclerosis as well as poor neointimal coverage at 11 months after stent implantation
    corecore