443 research outputs found

    Street crossing behavior in younger and older pedestrians: an eye- and head-tracking study

    Get PDF
    Background Crossing a street can be a very difficult task for older pedestrians. With increased age and potential cognitive decline, older people take the decision to cross a street primarily based on vehicles’ distance, and not on their speed. Furthermore, older pedestrians tend to overestimate their own walking speed, and could not adapt it according to the traffic conditions. Pedestrians’ behavior is often tested using virtual reality. Virtual reality presents the advantage of being safe, cost-effective, and allows using standardized test conditions. Methods This paper describes an observational study with older and younger adults. Street crossing behavior was investigated in 18 healthy, younger and 18 older subjects by using a virtual reality setting. The aim of the study was to measure behavioral data (such as eye and head movements) and to assess how the two age groups differ in terms of number of safe street crossings, virtual crashes, and missed street crossing opportunities. Street crossing behavior, eye and head movements, in older and younger subjects, were compared with non-parametric tests. Results The results showed that younger pedestrians behaved in a more secure manner while crossing a street, as compared to older people. The eye and head movements analysis revealed that older people looked more at the ground and less at the other side of the street to cross. Conclusions The less secure behavior in street crossing found in older pedestrians could be explained by their reduced cognitive and visual abilities, which, in turn, resulted in difficulties in the decision-making process, especially under time pressure. Decisions to cross a street are based on the distance of the oncoming cars, rather than their speed, for both groups. Older pedestrians look more at their feet, probably because of their need of more time to plan precise stepping movement and, in turn, pay less attention to the traffic. This might help to set up guidelines for improving senior pedestrians’ safety, in terms of speed limits, road design, and mixed physical-cognitive trainings

    Effects of age and eccentricity on visual target detection

    Get PDF
    The aim of this study was to examine the effects of aging and target eccentricity on a visual search task comprising 30 images of everyday life projected into a hemisphere, realizing a ±90° visual field. The task performed binocularly allowed participants to freely move their eyes to scan images for an appearing target or distractor stimulus (presented at 10°; 30°, and 50° eccentricity). The distractor stimulus required no response, while the target stimulus required acknowledgment by pressing the response button. One hundred and seventeen healthy subjects (mean age = 49.63 years, SD = 17.40 years, age range 20–78 years) were studied. The results show that target detection performance decreases with age as well as with increasing eccentricity, especially for older subjects. Reaction time also increases with age and eccentricity, but in contrast to target detection, there is no interaction between age and eccentricity. Eye movement analysis showed that younger subjects exhibited a passive search strategy while older subjects exhibited an active search strategy probably as a compensation for their reduced peripheral detection performance

    Effects of Alzheimer’s Disease on Visual Target Detection: A “Peripheral Bias”

    Get PDF
    Visual exploration is an omnipresent activity in everyday life, and might represent an important determinant of visual attention deficits in patients with Alzheimer’s Disease (AD). The present study aimed at investigating visual search performance in AD patients, in particular target detection in the far periphery, in daily living scenes. Eighteen AD patients and 20 healthy controls participated in the study. They were asked to freely explore a hemispherical screen, covering ±90°, and to respond to targets presented at 10°, 30°, and 50° eccentricity, while their eye movements were recorded. Compared to healthy controls, AD patients recognized less targets appearing in the center. No difference was found in target detection in the periphery. This pattern was confirmed by the fixation distribution analysis. These results show a neglect for the central part of the visual field for AD patients and provide new insights by mean of a search task involving a larger field of view

    Hemispheric asymmetry in visuospatial attention assessed with transcranial magnetic stimulation

    Get PDF
    Transcranial magnetic stimulation (TMS) was used to study visuospatial attention processing in ten healthy volunteers. In a forced choice recognition task the subjects were confronted with two symbols simultaneously presented during 120ms at random positions, one in the left and the other in the right visual field. The subject had to identify the presented pattern out of four possible combinations and to press the corresponding response key within 2 s. Double-pulse TMS (dTMS) with a 100-ms interstimulus interval (ISI) and an intensity of 80% of the stimulator output (corresponding to 110-120% of the motor threshold) was applied by a nonfocal coil over the right or left posterior parietal cortex (PPC, corresponding to P3/P4 of the international 10-20 system) at different time intervals after onset of the visual stimulus (starting at 120ms, 270ms and 520ms). Double-pulse TMS over the right PPC starting at 270ms led to a significant increase in percentage of errors in the contralateral, left visual field (median: 23% with TMS vs 13% without TMS, P=0.0025). TMS applied earlier or later showed no effect. Furthermore, no significant increase in contra- or ipsilateral percentage of errors was found when the left parietal cortex was stimulated with the same timing. These data indicate that: (1) parietal influence on visuospatial attention is mainly controlled by the right lobe since the same stimulation over the left parietal cortex had no significant effect, and (2) there is a vulnerable time window to disturb this cortical process, since dTMS had a significant effect on the percentage of errors in the contralateral visual hemifield only when applied 270ms after visual stimulus presentatio

    Round-Robin evaluation of the methodology for filtration efficiency tests in different filter media against nanoparticles

    Get PDF
    The filtration of airborne nanoparticles is becoming an important issue as they are produced in large quantities from material synthesis and combustion emission. Current international standards dealing with efficiency test for filters and filter media focus on measurement of the minimum efficiency at the most penetrating particle size. The available knowledge and instruments provide a solid base for development of test methods to determine the effectiveness of filtration media against airborne nanoparticles down to single-digit nanometer range. An interlaboratory evaluation was performed under the Technical Committee 195 of European Committee for Standardization (CEN/TC195) for the development of the methodology to determine effectiveness of filtration media against airborne particles in the 3 – 500 nm range. Five different laboratories, ETH/Empa, University of Minnesota, Politecnico di Torino, Unifil and Camfil, participated in the round robin test in order to ensure the accuracy of the test method. The qualification of test rig and apparatus was performed prior of the filtration ef-ficiency measurement tests. Experimental data are presented and their validity is discussed

    Saccadic eye movement changes in Parkinson's disease dementia and dementia with Lewy bodies

    Get PDF
    Neurodegeneration in Parkinson's disease dementia (PDD) and dementia with Lewy bodies (DLB) affect cortical and subcortical networks involved in saccade generation. We therefore expected impairments in saccade performance in both disorders. In order to improve the pathophysiological understanding and to investigate the usefulness of saccades for differential diagnosis, saccades were tested in age- and education-matched patients with PDD (n = 20) and DLB (n = 20), Alzheimer's disease (n = 22) and Parkinson's disease (n = 24), and controls (n = 24). Reflexive (gap, overlap) and complex saccades (prediction, decision and antisaccade) were tested with electro-oculography. PDD and DLB patients had similar impairment in all tasks (P > 0.05, not significant). Compared with controls, they were impaired in both reflexive saccade execution (gap and overlap latencies, P 0.05). Patients with Parkinson's disease had, compared with controls, similar complex saccade performance (for all, P > 0.05) and only minimal impairment in reflexive tasks, i.e. hypometric gain in the gap task (P = 0.04). Impaired saccade execution in reflexive tasks allowed discrimination between DLB versus Alzheimer's disease (sensitivity ≥60%, specificity ≥77%) and between PDD versus Parkinson's disease (sensitivity ≥60%, specificity ≥88%) when ±1.5 standard deviations was used for group discrimination. We conclude that impairments in reflexive saccades may be helpful for differential diagnosis and are minimal when either cortical (Alzheimer's disease) or nigrostriatal neurodegeneration (Parkinson's disease) exists solely; however, they become prominent with combined cortical and subcortical neurodegeneration in PDD and DLB. The similarities in saccade performance in PDD and DLB underline the overlap between these conditions and underscore differences from Alzheimer's disease and Parkinson's diseas

    Interlaboratory comparison to evaluate the methodology for determination of the media filtration efficiency against nanoparticles

    Get PDF
    Current international standards dealing with efficiency test for filters and filter media focus on measurement of the minimum efficiency at the most penetrating particle size. The available knowledge and instruments provide a solid base for development of test methods to determine the effectiveness of filtration media against airborne nanoparticles down to single-digit nanometer range. An interlaboratory evaluation was performed in the framework of the European Mandate M/461 activities, within the Technical Committee 195 of European Committee for Standardization (CEN/TC195). The purpose was to develop a methodology to determine effectiveness of filtration media against air-borne particles in the 3 – 500 nm range. Five different laboratories (Camfil, ETH/Empa, Politecnico di Torino, University of Minnesota, Unifil) participate in the round robin test in order to verify the repeatability and reproducibility of the test method. The qualification of test rig and apparatus was performed prior of the filtration efficiency and air flow resistance measurement tests.Twilled dutch weave wire mesh was chosen to perform the validation filtration efficiency tests so as to ensure high uniformity of the samples being tested by each different laboratory. We present the experimental data with the discussion about their validity

    Manipulations to reduce simulator-related transient adverse health effects during simulated driving

    Get PDF
    User comfort during simulated driving is of key importance, since reduced comfort can confound the experiment and increase dropout rates. A common comfort-affecting factor is simulator-related transient adverse health effect (SHE). In this study, we propose and evaluate methods to adapt a virtual driving scene to reduce SHEs. In contrast to the manufacturer-provided high-sensory conflict scene (high-SCS), we developed a low-sensory conflict scene (low-SCS). Twenty young, healthy participants drove in both the high-SCS and the low-SCS scene for 10min on two different days (same time of day, randomized order). Before and after driving, participants rated SHEs by completing the Simulator Sickness Questionnaire (SSQ). During driving, several physiological parameters were recorded. After driving in the high-SCS, the SSQ score increased in average by 129.4 (122.9%, p=0.002) compared to an increase of 5.0 (3.4%, p=0.878) after driving in the low-SCS. In the low-SCS, skin conductance decreased by 13.8% (p<0.01) and saccade amplitudes increased by 16.1% (p<0.01). Results show that the investigated methods reduce SHEs in a younger population, and the low-SCS is well accepted by the users. We expect that these measures will improve user comfort

    Visual perception in Parkinson disease dementia and dementia with Lewy bodies

    Get PDF
    OBJECTIVE To quantify visual discrimination, space-motion, and object-form perception in patients with Parkinson disease dementia (PDD), dementia with Lewy bodies (DLB), and Alzheimer disease (AD). METHODS The authors used a cross-sectional study to compare three demented groups matched for overall dementia severity (PDD: n = 24; DLB: n = 20; AD: n = 23) and two age-, sex-, and education-matched control groups (PD: n = 24, normal controls [NC]: n = 25). RESULTS Visual perception was globally more impaired in PDD than in nondemented controls (NC, PD), but was not different from DLB. Compared to AD, PDD patients tended to perform worse in all perceptual scores. Visual perception of patients with PDD/DLB and visual hallucinations was significantly worse than in patients without hallucinations. CONCLUSIONS Parkinson disease dementia (PDD) is associated with profound visuoperceptual impairments similar to dementia with Lewy bodies (DLB) but different from Alzheimer disease. These findings are consistent with previous neuroimaging studies reporting hypoactivity in cortical areas involved in visual processing in PDD and DLB

    Convergence and divergence in the evolution of cat skulls: temporal and spatial patterns of morphological diversity

    Get PDF
    Background: Studies of biological shape evolution are greatly enhanced when framed in a phylogenetic perspective. Inclusion of fossils amplifies the scope of macroevolutionary research, offers a deep-time perspective on tempo and mode of radiations, and elucidates life-trait changes. We explore the evolution of skull shape in felids (cats) through morphometric analyses of linear variables, phylogenetic comparative methods, and a new cladistic study of saber-toothed cats. Methodology/Principal Findings: A new phylogenetic analysis supports the monophyly of saber-toothed cats (Machairodontinae) exclusive of Felinae and some basal felids, but does not support the monophyly of various sabertoothed tribes and genera. We quantified skull shape variation in 34 extant and 18 extinct species using size-adjusted linear variables. These distinguish taxonomic group membership with high accuracy. Patterns of morphospace occupation are consistent with previous analyses, for example, in showing a size gradient along the primary axis of shape variation and a separation between large and small-medium cats. By combining the new phylogeny with a molecular tree of extant Felinae, we built a chronophylomorphospace (a phylogeny superimposed onto a two-dimensional morphospace through time). The evolutionary history of cats was characterized by two major episodes of morphological divergence, one marking the separation between saber-toothed and modern cats, the other marking the split between large and small-medium cats. Conclusions/Significance: Ancestors of large cats in the ‘Panthera’ lineage tend to occupy, at a much later stage, morphospace regions previously occupied by saber-toothed cats. The latter radiated out into new morphospace regions peripheral to those of extant large cats. The separation between large and small-medium cats was marked by considerable morphologically divergent trajectories early in feline evolution. A chronophylomorphospace has wider applications in reconstructing temporal transitions across two-dimensional trait spaces, can be used in ecophenotypical and functional diversity studies, and may reveal novel patterns of morphospace occupation
    corecore