340 research outputs found
Photoemission Spectroscopy
Contains reports on two research projects.Joint Services Electronics Program (Contract DAAG29-78-C-0020
Higher 30-day mortality associated with the use of intramedullary nails compared with sliding hip screws for the treatment of trochanteric hip fractures:a prospective national registry study
Aims
The aim of this study was to investigate the association between the type of operation used to treat a trochanteric fracture of the hip and 30-day mortality.
Patients and Methods
Data on 82 990 patients from the National Hip Fracture Database were analyzed using generalized linear models with incremental case-mix adjustment for patient, non-surgical and surgical characteristics, and socioeconomic factors.
Results
The use of short and long intramedullary nails was associated with an increase in 30-day mortality (adjusted odds ratio (OR) 1.125, 95% confidence interval (CI) 1.040 to 1.218; p = 0.004) compared with the use of sliding hip screws (12.5% increase). If this were causative, it would represent 98 excess deaths over the four-year period of the study and one excess death would be caused by treating 112 patients with an intramedullary nail rather than a sliding hip screw.
Conclusion
There is a 12.5% increase in the risk of 30-day mortality associated with the use of an intramedullary nail compared with a sliding hip screw in the treatment of a trochanteric fractures of the hip.</p
Satellite observed water quality changes in the Laurentian Great Lakes due to invasive species, anthropogenic forcing, and climate change
Long time series of ocean and land color satellite data can be used to measure Laurentian Great Lakes water quality parameters including chlorophyll, suspended minerals, harmful algal blooms (HABs), photic zone and primary productivity on weekly, monthly and annual observational intervals. The observed changes in these water quality parameters over time are a direct result of the introduction of invasive species such as the Dreissena mussels as well as anthropogenic forcing and climate change. Time series of the above mentioned water quality parameters have been generated based on a range of satellite sensors, starting with Landsat in the 1970s and continuing to the present with MODIS and VIIRS. These time series have documented the effect the mussels have had on increased water clarity by decreasing the chlorophyll concentrations. Primary productivity has declined in the lakes due to the decrease in algae. The increased water clarity due to the mussels has also led to an increase in submerged aquatic vegetation. Comparing water quality metrics in Lake Superior to the lower lakes is insightful because Lake Superior is the largest and most northern of the five Great Lakes and to date has not been affected by the invasive mussels and can thus be considered a control. In contrast, Lake Erie, the most southern and shallow of the Laurentian Great Lakes, is heavily influenced by agricultural practices (i.e., nutrient runoff) and climate change, which directly influence the annual extent of HABs in the Western Basin of that lake
Analysis of change in patient-reported outcome measures with floor and ceiling effects using the multilevel Tobit model:a simulation study and an example from a National Joint Register using body mass index and the Oxford Hip Score
OBJECTIVES: This study has three objectives. (1) Investigate the association between body mass index (BMI) and the efficacy of primary hip replacement using a patient-reported outcome measure (PROMs) with a measurement floor and ceiling, (2) Explore the performance of different estimation methods to estimate change in PROMs score following surgery using a simulation study and real word data where data has measurement floors and ceilings and (3) Lastly, develop guidance for practising researchers on the analysis of PROMs in the presence of floor and ceiling effects. DESIGN: Simulation study and prospective national medical device register. SETTING: National Register of Joint Replacement and Medical Devices. METHODS: Using a Monte Carlo simulation study and data from a national joint replacement register (162 513 patients with pre- and post-surgery PROMs), we investigate simple approaches for the analysis of outcomes with floor and ceiling effects that are measured at two occasions: linear and Tobit regression (baseline adjusted analysis of covariance, change-score analysis, post-score analysis) in addition to linear and multilevel Tobit models. PRIMARY OUTCOME: The primary outcome of interest is change in PROMs from pre-surgery to 6 months post-surgery. RESULTS: Analysis of data with floor and ceiling effects with models that fail to account for these features induce substantial bias. Single-level Tobit models only correct for floor or ceiling effects when the exposure of interest is not associated with the baseline score. In observational data scenarios, only multilevel Tobit models are capable of providing unbiased inferences. CONCLUSIONS: Inferences from pre- post-studies that fail to account for floor and ceiling effects may induce spurious associations with substantial risk of bias. Multilevel Tobit models indicate the efficacy of total hip replacement is independent of BMI. Restricting access to total hip replacement based on a patients BMI can not be supported by the data
Photoemission Spectroscopy
Contains reports on two research projects.Joint Services Electronics Program (Contract DAAG29-78-C-0020
Photoemission Spectroscopy
Contains report on one research project.Joint Services Electronics Program (Contract DAAG29-78-C-0020)Joint Services Electronics Program (Contract DAAG29-80-C-0104
Schistosoma mansoni cercarial elastase (SmCE): differences in immunogenic properties of native and recombinant forms
The Schistosoma mansoni cercarial elastase (SmCE) has previously been shown to be poorly immunogenic in mice. However, a minority of mice were able to produce antibodies against SmCE after multiple immunizations with crude pre- parations containing the enzyme. These mice were partially protected against challenge infections of S. mansoni. In the present study, we show that in contrast to the poor immunogenicity of the enzymatically active native form of SmCE derived from a crude preparation (cercarial transformation fluid), immunization of CBA/Ca mice with two enzymatically inactive forms, namely purified native SmCE or a recombinant SmCE fused to recombinant Schistosoma japonicum gluta- thione S-transferase (rSmCE-SjGST), after adsorption onto aluminum hydroxide adjuvant, induced specific anti-SmCE immunoglobulin G (IgG) in all mice within 2 weeks of the second immunization. The IgG antibody response to rSmCE- SjGST was mainly of the IgG1 subclass. These results suggest that inactive forms of the antigen could be used to obtain the optimum immunogenic effects as a vaccine candidate against schistosomiasis. Mice immunized with the rSmCE- SjGST on alum had smaller mean worm burdens and lower tissue egg counts when compared with adjuvant alone- and recombinant SjGST-injected controls. The native SmCE was antigenically cross-reactive with homologous enzymes of Schistosoma haematobium and Schistosoma margrebowiei
- …