29 research outputs found

    High speed shutter

    Get PDF
    A shutter element is described which is formed by a loop of an electrically conductive ribbon disposed adjacent to the end of a passageway to be shuttered. The shuttered end of the passageway is cut at an acute angle. The two leg portions of the ribbon loop are closely spaced to each other and disposed in a plane parallel to the axis of the passageway. A pulse of high current is switched through the loop to cause the current flowing in opposite directions through adjacent leg portions of the ribbon. This produces a magnetically induced pressure on one of the legs of the ribbon forcing the leg over the end of the passageway in gas tight sealing engagement, and thereby blocking passageway

    Photomultiplier blanking circuit

    Get PDF
    Circuit for protecting photomultiplier equipment from current surges which occur when exposed to brilliant illumination is discussed. Components of circuit and details of operation are provided. Circuit diagram to show action of blanking pulse on zener diode is included

    Photomultiplier circuit including means for rapidly reducing the sensitivity thereof

    Get PDF
    A simple, reliable and inexpensive control circuit is described for rapidly reducing the bias voltage across one or more of the dynode stages of a photomultiplier, to substantially decrease its sensitivity to incoming light at those times where excess light intensity might damage the tube. The control circuit comprises a switching device, such as a silicon controlled rectifier (SCR), coupled between a pair of the electrodes in the tube, preferably the cathode and first dynode, or the first and second dynodes, the switching device operating in response to a trigger pulse applied to its gate to short circuit the two electrodes. To insure the desired reduction in sensitivity, two switching stages, the devices be employed between two of the electrode stages, the devices being operated simultaneously to short circuit both stages

    Optical shutter for use in shock tubes

    Get PDF
    Thin metal shutter that is forced into angled optical slit isolates spectrograph from high speed shock tube both optically and mechanically so neither radiation nor particulate material enters spectrograph

    Calibration of radiation detectors in the ultraviolet region between 972 and 2500 A

    Get PDF
    The development of experimental setups and procedures is considered for calibrating photosensitive devices in the spectral range 1022 to 2500 A for which no direct calibration techniques exist. An indirect technique that uses a sodium salicylate detector calibrated outside this range was developed for use as a secondary standard. The primary standard was a xenon-filled ionization chamber, which is an absolute standard over the wavelength interval 972 to 1022 A. Measurements made by this method were checked at 1470 A with a xenon lamp and at 2537 A with a mercury arc lamp and a 0.5 m blaze monochromator with a grating blazed at 2000 A. The overall accuracy of the measurements was + or - 40 percent or better

    Factors associated with testicular self-examination among unaffected men from multiple-case testicular cancer families

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The lifetime testicular cancer (TC) risk in the general population is relatively low (~1 in 250), but men with a family history of TC are at 4 to 9 times greater risk than those without. Some health and professional organizations recommend consideration of testicular self-examination (TSE) for certain high-risk groups (e.g. men with a family history of TC). Yet little is known about factors associated with TSE behaviors in this at-risk group.</p> <p>Methods</p> <p>We collected information on this subject during an on-going NCI multidisciplinary, etiologically-focused, cross-sectional Familial Testicular Cancer (FTC) study. We present the first report specifically targeting TSE behaviors among first- and second-degree relatives (n = 99) of affected men from families with ≥ 2 TC cases. Demographic, medical, knowledge, health belief, and psychological factors consistent with the Health Belief Model (HBM) were evaluated as variables related to TSE behavior, using chi-square tests of association for categorical variables, and t-tests for continuous variables.</p> <p>Results</p> <p>For men in our sample, 46% (n = 46) reported performing TSE regularly and 51% (n = 50) reported not regularly performing TSE. Factors associated (p < .05) with regularly performing TSE in multivariate analysis were physician recommendation and testicular cancer worry. This is the first study to examine TSE in unaffected men from FTC families.</p> <p>Conclusion</p> <p>The findings suggest that, even in this high-risk setting, TSE practices are sub-optimal. Our data provide a basis for further exploring psychosocial issues that are specific to men with a family history of TC, and formulating intervention strategies aimed at improving adherence to TSE guidelines.</p

    Changes in plasma protein concentrations in ponies with experimentally induced alimentary laminitis

    No full text
    Objective-To determine whether plasma protein concentrations were altered in ponies with alimentary laminitis.Animals-12 adult ponies.Procedure-Acute laminitis was induced in 6 ponies by oral administration of carbohydrate (85% corn starch, 15% wood flour); the other 6 ponies were used as controls. A physical examination was performed and blood samples were collected immediately before and 4, 8, 12, 24, and 28 hours after administration of carbohydrate. Plasma protein concentrations were determined by means of sodium dodecyl sulphate-polyacrylamide gel electrophoresis.Results-19 plasma proteins ranging from a molecular weight of 24,000 to a molecular weight of 350,000 were identified in all 12 ponies. Plasma concentrations of proteins with molecular weights of 350,000 (fibrinogen), 130,000 (ceruloplasmin), 118,000 (c-reactive protein), 67,000 (alpha(1)-antitrypsin I), 65,000 (alpha(1)-antitrypsin II), 50,000 (haptoglobulin), and 45,000 (acid glycoprotein) were significantly increased in ponies with laminitis, compared with concentrations in control ponies.Conclusion-Changes in plasma protein concentrations are detectable within 4 hours after the onset of alimentary laminitis in ponies.Clinical Relevance-Measurement of plasma protein concentrations may be useful in monitoring the progression of laminitis in ponies
    corecore