474 research outputs found

    An interactive medical image segmentation system based on the optimal management of regions of interest using topological medical knowledge

    Get PDF
    This paper presents an original interactive system for efficient medical image segmentation in computer aided diagnosis. The main originality concerns the method used to manage, according to an a priori topological-based structural model, regions of interest (ROIs) within which computations can be constrained. The goal is then to avoid the processing of irrelevant image points, therefore improving and accelerating segmentations. In the case of a hierarchical modeling procedure, our ROI management method enables, for delineating a given medical structure, to optimally determine image points of interest by taking previously segmented structures into account. We propose a mathematical formulation of the method as well as a possible implementation within an interactive system. We also detail an experience report focussing on the segmentation of several abdominal structures from a CT image. It illustrates the behavior and the potential of our method

    Phylogeny and androgenesis in the invasive <i>Corbicula</i> clams (Bivalvia, Corbiculidae) in Western Europe

    Get PDF
    Background The genus Corbicula is one of the most invasive groups of molluscs. It includes both sexual and androgenetic lineages. The present study re-assessed the different morphotypes and haplotypes of West European Corbicula in order to clarify their taxonomic identification and phylogenetic relationships with American and Asian Corbicula clams. We studied several populations from West European river basins (Meuse, Seine, Rhine and Rhône) through an "integrative taxonomy" approach. We combined morphology, partial mitochondrial COI and cyt b sequences and eleven microsatellite loci. Furthermore, we looked for discrepancies between mtDNA and nrDNA/morphology, indicative of androgenesis between lineages. Results There are three Corbicula morphotypes in Western Europe associated to three mitochondrial lineages and three genotypes. Form R shares the same COI haplotype as the American form A and the Japanese C. leana. Form S and the American form C have the same haplotype, although their morphologies seem divergent. The European form Rlc belongs to the same mitochondrial lineage as both the American form B and the Asian C. fluminea. Interestingly, within each haplotype/genotype or lineage, no genetic diversity was found although their invasive success is high. Moreover, we detected rare mismatches between mtDNA and nrDNA/morphology, indicative of androgenesis and mitochondrial capture between form R and form S and therefore challenging the phylogenetic relatedness and the species status within this genus. The global phylogenetic analysis revealed that the sexual Corbicula lineages seem restricted to the native areas while their androgenetic relatives are widespread and highly invasive. Conclusions We clarified the discrepancies and incongruent results found in the literature about the European morphotypes of Corbicula and associated mitochondrial lineages. The three West European morphotypes belong to three distinct nuclear and mitochondrial lineages. However mitochondrial capture occurs in sympatric populations of forms R and S. The species status of the morphotypes therefore remains doubtful. Moreover the androgenetic lineages seem widely distributed compared to their sexual relatives, suggesting that androgenesis and invasive success may be linked in the genus Corbicula

    A modular magnetic anastomotic device for minimally invasive digestive anastomosis: proof of concept and preliminary data in the pig model.

    Get PDF
    BACKGROUND: The aim of our study was to assess the feasibility of minimally invasive digestive anastomosis using a modular flexible magnetic anastomotic device made up of a set of two flexible chains of magnetic elements. The assembly possesses a non-deployed linear configuration which allows it to be introduced through a dedicated small-sized applicator into the bowel where it takes the deployed form. A centering suture allows the mating between the two parts to be controlled in order to include the viscerotomy between the two magnetic rings and the connected viscera. METHODS AND PROCEDURES: Eight pigs were involved in a 2-week survival experimental study. In five colorectal anastomoses, the proximal device was inserted by a percutaneous endoscopic technique, and the colon was divided below the magnet. The distal magnet was delivered transanally to connect with the proximal magnet. In three jejunojejunostomies, the first magnetic chain was injected in its linear configuration through a small enterotomy. Once delivered, the device self-assembled into a ring shape. A second magnet was injected more distally through the same port. The centering sutures were tied together extracorporeally and, using a knot pusher, magnets were connected. Ex vivo strain testing to determine the compression force delivered by the magnetic device, burst pressure of the anastomosis, and histology were performed. RESULTS: Mean operative time including endoscopy was 69.2 ± 21.9 min, and average time to full patency was 5 days for colorectal anastomosis. Operative times for jejunojejunostomies were 125, 80, and 35 min, respectively. The postoperative period was uneventful. Burst pressure of all anastomoses was ≥ 110 mmHg. Mean strain force to detach the devices was 6.1 ± 0.98 and 12.88 ± 1.34 N in colorectal and jejunojejunal connections, respectively. Pathology showed a mild-to-moderate inflammation score. CONCLUSIONS: The modular magnetic system showed enormous potential to create minimally invasive digestive anastomoses, and may represent an alternative to stapled anastomoses, being easy to deliver, effective, and low cost

    Upstaging nodal status in colorectal cancer using ex vivo fluorescence sentinel lymph node mapping: preliminary results

    Get PDF
    Background: Sentinel lymph node (SLN) mapping using near-infrared fluorescence (NIRF) imaging is a recent technique to improve nodal staging in several tumors. The presence of colorectal cancer (CRC) micro-metastases has recently been defined as N1 disease and no longer as N1mi, determining the need for adjuvant chemotherapy. In CRC, the reported rate of SLN micro-metastases detected by ultrastaging techniques is as high as 30%. The aim of this prospective study is to report the preliminary results of the sensitivity analysis of NIRF imaging for ex vivo SLN mapping and the research of micro-metastases in CRC, in patients with node-negative disease (NND). Material and methods: On the specimen of 22 CRC patients, 1 mL of ICG (5 mg/mL) was injected submucosally around the tumor to identify SLNs. NND SLNs were further investigated with ultrastaging techniques. Results: Three-hundred and sixty-three lymph nodes were retrieved (59 SLNs; mean per case: 2.7). The detection, sensitivity and false-negative rate were 100%, 100% and 0% respectively. Ultrastaging investigations showed no micro-metastases in the NND SLNs. Conclusions: The ex vivo SLN fluorescence-based detection in CRC was confirmed to be easy to perform and reliable. In this preliminary results report of an ongoing study, the SLN assay was congruent with the nodal status, as confirmed by histological investigations

    Image-Guided Surgical e-Learning in the Post-COVID-19 Pandemic Era: What Is Next?

    Get PDF
    The current unprecedented coronavirus 2019 (COVID-19) crisis has accelerated and enhanced e-learning solutions. During the so-called transition phase, efforts were made to reorganize surgical services, reschedule elective surgical procedures, surgical research, academic education, and careers to optimize results. The intention to switch to e-learning medical education is not a new concern. However, the current crisis triggered an alarm to accelerate the transition. Efforts to consider e-learning as a teaching and training method for medical education have proven to be efficient. For image-guided therapies, the challenge requires more effort since surgical skills training is combined with image interpretation training, thus the challenge is to cover quality educational content with a balanced combination of blended courses (online/onsite). Several e-resources are currently available in the surgical scenario; however, further efforts to enhance the current system are required by accelerating the creation of new learning solutions to optimize complex surgical education needs in the current disrupted environment

    Simultaneous computer-assisted assessment of mucosal and serosal perfusion in a model of segmental colonic ischemia

    Get PDF
    BACKGROUND: Fluorescence-based enhanced reality (FLER) enables the quantification of fluorescence signal dynamics, which can be superimposed onto real-time laparoscopic images by using a virtual perfusion cartogram. The current practice of perfusion assessment relies on visualizing the bowel serosa. The aim of this experimental study was to quantify potential differences in mucosal and serosal perfusion levels in an ischemic colon segment. METHODS: An ischemic colon segment was created in 12 pigs. Simultaneous quantitative mucosal and serosal fluorescence imaging was obtained via intravenous indocyanine green injection (0.2 mg/kg), using two near-infrared camera systems, and computer-assisted FLER analysis. Lactate levels were measured in capillary blood of the colonic wall at seven regions of interest (ROIs) as determined with FLER perfusion cartography: the ischemic zone (I), the proximal and distal vascularized areas (PV, DV), and the 50% perfusion threshold proximally and distally at the mucosal and serosal side (P50M, P50S, D50M, D50S). RESULTS: The mean ischemic zone as measured (mm) for the mucosal side was significantly larger than the serosal one (56.3 ± 21.3 vs. 40.8 ± 14.9, p = 0.001) with significantly lower lactate values at the mucosal ROIs. There was a significant weak inverse correlation between lactate and slope values for the defined ROIs (r = - 0.2452, p = 0.0246). CONCLUSIONS: Mucosal ischemic zones were larger than serosal zones. These results suggest that an assessment of bowel perfusion from the serosal side only can underestimate the extent of ischemia. Further studies are required to predict the optimal resection margin and anastomotic site

    Surgical Models of Liver Regeneration in Pigs. A Practical Review of the Literature for Researchers

    Get PDF
    The remarkable capacity of regeneration of the liver is well known, although the involved mechanisms are far from being understood. Furthermore, limits concerning the residual functional mass of the liver remain critical in both fields of hepatic resection and transplantation. The aim of the present study was to review the surgical experiments regarding liver regeneration in pigs to promote experimental methodological standardization. The Pubmed, Medline, Scopus, and Cochrane Library databases were searched. Studies evaluating liver regeneration through surgical experiments performed on pigs were included. A total of 139 titles were screened, and 41 articles were included in the study, with 689 pigs in total. A total of 29 studies (71% of all) had a survival design, with an average study duration of 13 days. Overall, 36 studies (88%) considered partial hepatectomy, of which four were an associating liver partition and portal vein ligation for staged hepatectomy (ALPPS). Remnant liver volume ranged from 10% to 60%. Only 2 studies considered a hepatotoxic pre-treatment, while 25 studies evaluated additional liver procedures, such as stem cell application, ischemia/reperfusion injury, portal vein modulation, liver scaffold application, bio-artificial, and pharmacological liver treatment. Only nine authors analysed how cytokines and growth factors changed in response to liver resection. The most used imaging system to evaluate liver volume was CT-scan volumetry, even if performed only by nine authors. The pig represents one of the best animal models for the study of liver regeneration. However, it remains a mostly unexplored field due to the lack of experiments reproducing the chronic pathological aspects of the liver and the heterogeneity of existing studies
    corecore