6 research outputs found

    Propagation of uncertainty through the hazard chain

    Get PDF
    DSTL wish to explore methods for propagating uncertainty through a succession of linked models. The Study Group have looked at the particular example of casualty estimation from airbourne dispersion and suggested two different potential solutions. If the structure of the models is sufficiently simple, and the number of degrees of freedom relatively small, a semi-analytical approach based on Bayes’ theorem can be used. In the more general case, intelligent sampling methods can be used to gradually build a picture of likely outcomes

    STAT3-mediated astrocyte reactivity associated with brain metastasis contributes to neurovascular dysfunction

    Get PDF
    © 2020 American Association for Cancer Research. Astrocytes are thought to play a pivotal role in coupling neural activity and cerebral blood flow. However, it has been shown that astrocytes undergo morphologic changes in response to brain metastasis, switching to a reactive phenotype, which has the potential to significantly compromise cerebrovascular function and contribute to the neurological sequelae associated with brain metastasis. Given that STAT3 is a key regulator of astrocyte reactivity, we aimed here to determine the impact of STAT3- mediated astrocyte reactivity on neurovascular function in brain metastasis. Rat models of brain metastasis and ciliary neurotrophic factor were used to induce astrocyte reactivity. Multimodal imaging, electrophysiology, and IHC were performed to determine the relationship between reactive astrocytes and changes in the cerebrovascular response to electrical and physiological stimuli. Subsequently, the STAT3 pathway in astrocytes was inhibited with WP1066 to determine the role of STAT3- mediated astrocyte reactivity, specifically, in brain metastasis. Astrocyte reactivity associated with brain metastases impaired cerebrovascular responses to stimuli at both the cellular and functional level and disrupted astrocyte-endothelial interactions in both animal models and human brain metastasis samples. Inhibition of STAT3-mediated astrocyte reactivity in rats with brain metastases restored cerebrovascular function, as shown by in vivo imaging, and limited cerebrovascular changes associated with tumor growth. Together these findings suggest that inhibiting STAT3-mediated astrocyte reactivity may confer significant improvements in neurological outcome for patients with brain metastases and could potentially be tested in other brain tumors

    Investigations into the effects of neuromodulations on the BOLD-fMRI signal

    No full text
    The blood oxygen level dependent functional MRI (BOLD-fMRI) signal is an indirect measure of the neuronal activity that most BOLD studies are interested in. This thesis uses generative embedding algorithms to investigate some of the challenges and opportunities that this presents for BOLD imaging. It is standard practice to analyse BOLD signals using general linear models (GLMs) that assume fixed neurovascular coupling. However, this assumption may cause false positive or negative neural activations to be detected if the biological manifestations of brain diseases, disorders and pharmaceutical drugs (termed "neuromodulations") alter this coupling. Generative embedding can help overcome this problem by identifying when a neuromodulation confounds the standard GLM. When applied to anaesthetic neuromodulations found in preclinical imaging data, Fentanyl has the smallest confounding effect and Pentobarbital has the largest, causing extremely significant neural activations to go undetected. Half of the anaesthetics tested caused overestimation of the neuronal activity but the other half caused underestimation. The variability in biological action between anaesthetic modulations in identical brain regions of genetically similar animals highlights the complexity required to comprehensively account for factors confounding neurovascular coupling in GLMs generally. Generative embedding has the potential to augment established algorithms used to compensate for these variations in GLMs without complicating the standard (ANOVA) way of reporting BOLD results. Neuromodulation of neurovascular coupling can also present opportunities, such as improved diagnosis, monitoring and understanding of brain diseases accompanied by neurovascular uncoupling. Information theory is used to show that the discriminabilities of neurodegenerative-diseased and healthy generative posterior parameter spaces make generative embedding a viable tool for these commercial applications, boasting sensitivity to neurovascular coupling nonlinearities and biological interpretability. The value of hybrid neuroimaging systems over separate neuroimaging technologies is found to be greatest for early-stage neurodegenerative disease.</p

    Investigations into the effects of neuromodulations on the BOLD-fMRI signal

    No full text
    The blood oxygen level dependent functional MRI (BOLD-fMRI) signal is an indirect measure of the neuronal activity that most BOLD studies are interested in. This thesis uses generative embedding algorithms to investigate some of the challenges and opportunities that this presents for BOLD imaging. It is standard practice to analyse BOLD signals using general linear models (GLMs) that assume fixed neurovascular coupling. However, this assumption may cause false positive or negative neural activations to be detected if the biological manifestations of brain diseases, disorders and pharmaceutical drugs (termed "neuromodulations") alter this coupling. Generative embedding can help overcome this problem by identifying when a neuromodulation confounds the standard GLM. When applied to anaesthetic neuromodulations found in preclinical imaging data, Fentanyl has the smallest confounding effect and Pentobarbital has the largest, causing extremely significant neural activations to go undetected. Half of the anaesthetics tested caused overestimation of the neuronal activity but the other half caused underestimation. The variability in biological action between anaesthetic modulations in identical brain regions of genetically similar animals highlights the complexity required to comprehensively account for factors confounding neurovascular coupling in GLMs generally. Generative embedding has the potential to augment established algorithms used to compensate for these variations in GLMs without complicating the standard (ANOVA) way of reporting BOLD results. Neuromodulation of neurovascular coupling can also present opportunities, such as improved diagnosis, monitoring and understanding of brain diseases accompanied by neurovascular uncoupling. Information theory is used to show that the discriminabilities of neurodegenerative-diseased and healthy generative posterior parameter spaces make generative embedding a viable tool for these commercial applications, boasting sensitivity to neurovascular coupling nonlinearities and biological interpretability. The value of hybrid neuroimaging systems over separate neuroimaging technologies is found to be greatest for early-stage neurodegenerative disease.This thesis is not currently available on ORA

    Measurement of Vital Signs by Lifelight Software in Comparison to Standard of Care Multisite Development (VISION-MD): Protocol for an Observational Study

    No full text
    BackgroundMeasuring vital signs (VS) is an important aspect of clinical care but is time-consuming and requires multiple pieces of equipment and trained staff. Interest in the contactless measurement of VS has grown since the COVID-19 pandemic, including in nonclinical situations. Lifelight is an app being developed as a medical device for the contactless measurement of VS using remote photoplethysmography (rPPG) via the camera on smart devices. The VISION-D (Measurement of Vital Signs by Lifelight Software in Comparison to the Standard of Care—Development) and VISION-V (Validation) studies demonstrated the accuracy of Lifelight compared with standard-of-care measurement of blood pressure, pulse rate, and respiratory rate, supporting the certification of Lifelight as a class I Conformité Européenne (CE) medical device. ObjectiveTo support further development of the Lifelight app, the observational VISION Multisite Development (VISION-MD) study is collecting high-quality data from a broad range of patients, including those with VS measurements outside the normal healthy range and patients who are critically ill. MethodsThe study is recruiting adults (aged ≥16 years) who are inpatients (some critically ill), outpatients, and healthy volunteers, aiming to cover a broad range of normal and clinically relevant VS values; there are no exclusion criteria. High-resolution 60-second videos of the face are recorded by the Lifelight app while simultaneously measuring VS using standard-of-care methods (automated sphygmomanometer for blood pressure; finger clip sensor for pulse rate and oxygen saturation; manual counting of respiratory rate). Feedback from patients and nurses who use Lifelight is collected via a questionnaire. Data to estimate the cost-effectiveness of Lifelight compared with standard-of-care VS measurement are also being collected. A new method for rPPG signal processing is currently being developed, based on the identification of small areas of high-quality signals in each individual. Anticipated recruitment is 1950 participants, with the expectation that data from approximately 1700 will be used for software development. Data from 250 participants will be retained to test the performance of Lifelight against predefined performance targets. ResultsRecruitment began in May 2021 but was hindered by the restrictions instigated during the COVID-19 pandemic. The development of data processing methodology is in progress. The data for analysis will become available from September 2022, and the algorithms will be refined continuously to improve clinical accuracy. The performance of Lifelight compared with that of the standard-of-care measurement of VS will then be tested. Recruitment will resume if further data are required. The analyses are expected to be completed in early 2023. ConclusionsThis study will support the refinement of data collection and processing toward the development of a robust app that is suitable for routine clinical use. Trial RegistrationClinicalTrials.gov NCT04763746; https://clinicaltrials.gov/ct2/show/NCT04763746 International Registered Report Identifier (IRRID)DERR1-10.2196/4153

    Measurement of Vital Signs Using Lifelight Remote Photoplethysmography: Results of the VISION-D and VISION-V Observational Studies

    No full text
    BackgroundThe detection of early changes in vital signs (VSs) enables timely intervention; however, the measurement of VSs requires hands-on technical expertise and is often time-consuming. The contactless measurement of VSs is beneficial to prevent infection, such as during the COVID-19 pandemic. Lifelight is a novel software being developed to measure VSs by remote photoplethysmography based on video captures of the face via the integral camera on mobile phones and tablets. We report two early studies in the development of Lifelight. ObjectiveThe objective of the Vital Sign Comparison Between Lifelight and Standard of Care: Development (VISION-D) study (NCT04763746) was to measure respiratory rate (RR), pulse rate (PR), and blood pressure (BP) simultaneously by using the current standard of care manual methods and the Lifelight software to iteratively refine the software algorithms. The objective of the Vital Sign Comparison Between Lifelight and Standard of Care: Validation (VISION-V) study (NCT03998098) was to validate the use of Lifelight software to accurately measure VSs. MethodsBP, PR, and RR were measured simultaneously using Lifelight, a sphygmomanometer (BP and PR), and the manual counting of RR. Accuracy performance targets for each VS were defined from a systematic literature review of the performance of state-of-the-art VSs technologies. ResultsThe VISION-D data set (17,233 measurements from 8585 participants) met the accuracy targets for RR (mean error 0.3, SD 3.6 vs target mean error 2.3, SD 5.0; n=7462), PR (mean error 0.3, SD 4.0 vs mean error 2.2, SD 9.2; n=10,214), and diastolic BP (mean error −0.4, SD 8.5 vs mean error 5.5, SD 8.9; n=8951); for systolic BP, the mean error target was met but not the SD (mean error 3.5, SD 16.8 vs mean error 6.7, SD 15.3; n=9233). Fitzpatrick skin type did not affect accuracy. The VISION-V data set (679 measurements from 127 participants) met all the standards: mean error −0.1, SD 3.4 for RR; mean error 1.4, SD 3.8 for PR; mean error 2.8, SD 14.5 for systolic BP; and mean error −0.3, SD 7.0 for diastolic BP. ConclusionsAt this early stage in development, Lifelight demonstrates sufficient accuracy in the measurement of VSs to support certification for a Level 1 Conformité Européenne mark. As the use of Lifelight does not require specific training or equipment, the software is potentially useful for the contactless measurement of VSs by nonclinical staff in residential and home care settings. Work is continuing to enhance data collection and processing to achieve the robustness and accuracy required for routine clinical use. International Registered Report Identifier (IRRID)RR2-10.2196/1432
    corecore