120 research outputs found

    Spin Motion in Electron Transmission through Ultrathin Ferromagnetic Films Accessed by Photoelectron Spectroscopy

    Full text link
    Ab initio and model calculations demonstrate that the spin motion of electrons transmitted through ferromagnetic films can be analyzed in detail by means of angle- and spin-resolved core-level photoelectron spectroscopy. The spin motion appears as precession of the photoelectron spin polarization around and as relaxation towards the magnetization direction. In a systematic study for ultrathin Fe films on Pd(001) we elucidate its dependence on the Fe film thickness and on the Fe electronic structure. In addition to elastic and inelastic scattering, the effect of band gaps on the spin motion is addressed in particular.Comment: 4 pages, 5 figure

    Auger Effect in the High-Resolution Ce 3d-edge Resonant Photoemission

    Full text link
    The bulk-sensitive Ce 4ff spectral weights of various Ce compounds including CeFe2_2, CeNi2_2, and CeSi2_2 were obtained with the resonant photoemission technique at the Ce 3d-edge. We found the lineshapes change significantly with the small change of the incident photon energy. Detailed analysis showed that this phenomenon results primarily from the Auger transition between different multiplet states of the Ce 3d5/2‟4f2\underline{3d_{5/2}}4f^2 (bar denotes a hole) electronic configuration in the intermediate state of the resonant process. This tells us that extra care should be taken for the choice of the resonant photon energy when extracting Ce 4ff spectral weights from the Ce 3dd-edge resonant photoemission spectra. The absorption energy corresponding to the lowest multiplet structure of the Ce 3d5/2‟4f2\underline{3d_{5/2}}4f^2 configuration seems to be the logical choice.Comment: 13 pages, 5 figures, submitted to Phys. Rev.

    Reducing the environmental impact of surgery on a global scale: systematic review and co-prioritization with healthcare workers in 132 countries

    Get PDF
    Background Healthcare cannot achieve net-zero carbon without addressing operating theatres. The aim of this study was to prioritize feasible interventions to reduce the environmental impact of operating theatres. Methods This study adopted a four-phase Delphi consensus co-prioritization methodology. In phase 1, a systematic review of published interventions and global consultation of perioperative healthcare professionals were used to longlist interventions. In phase 2, iterative thematic analysis consolidated comparable interventions into a shortlist. In phase 3, the shortlist was co-prioritized based on patient and clinician views on acceptability, feasibility, and safety. In phase 4, ranked lists of interventions were presented by their relevance to high-income countries and low–middle-income countries. Results In phase 1, 43 interventions were identified, which had low uptake in practice according to 3042 professionals globally. In phase 2, a shortlist of 15 intervention domains was generated. In phase 3, interventions were deemed acceptable for more than 90 per cent of patients except for reducing general anaesthesia (84 per cent) and re-sterilization of ‘single-use’ consumables (86 per cent). In phase 4, the top three shortlisted interventions for high-income countries were: introducing recycling; reducing use of anaesthetic gases; and appropriate clinical waste processing. In phase 4, the top three shortlisted interventions for low–middle-income countries were: introducing reusable surgical devices; reducing use of consumables; and reducing the use of general anaesthesia. Conclusion This is a step toward environmentally sustainable operating environments with actionable interventions applicable to both high– and low–middle–income countries
    • 

    corecore