7 research outputs found

    Assessor-related factors and score differences between ethnically diverse Dutch police applicants

    Get PDF
    The present study examined the effects of demographic and perceived similarity between assessors and applicants on assessors’ evaluations of Dutch ethnic majority and minority applicants. Results showed that demographic similarity did not explain score differences between ethnic groups. Perceived similarity did explain score differences, but for Turkish applicants solely

    Arterial stenting with self-expandable and balloon-expandable endoprostheses

    Get PDF
    Coronary angioplasty is complicated by acute occlusion (within 24 hours) and late restenosis (within 6 months) in 2-5% and 20-40% of the cases, respectively. Vascular endoprostheses (stents) may provide the cardiologist with a solution to some of these complications. Several stent-devices are now available for experimental and clinical evaluation. In this study we describe our experience with two metallic stents in normal arteries of swine. Self-expandable, stainless steel stents (3.5 mm diameter) were implanted in 17 peripheral arteries, eight of which were deendothelialized by prior balloon angioplasty. Following implantation, the animals received antithrombotic therapy with acenocoumarol and aspirin (8 stents), or aspirin alone (9 stents). After 1 week repeat angiography was performed, which showed patency of all stented arteries. Microscopy showed complete covering by neointima, 80 μm in thickness. This self-expandable stent (SES) and a balloon-expandable stent (BES), constructed of tantalum, were implanted in normal coronary arteries. SES (3.0 and 3.5 mm) receiving animals were treated with coumadines (10 stents) or received no antithrombotic treatment (16 stents) after implantation. BES receiving animals were also not treated (10 stents). Three untreated animals with SES died suddenly within 48 hours. Postmortem examination showed partial or complete thrombosis of all six stents in these animals, resulting in a patency rate of 62% after 1 week. All animals with SES, which were treated with coumadines, and all animals with BES (untreated) had patent stents after one week. It is concluded that SES implanted in normal coronary arteries of pigs, which do not receive additional antithrombotic treatment, show a 38% occlusion rate within 48 hours, but show 100% patency after 1 week, when the animals are treated with coumadines. BES implanted in normal coronary arteries of pigs, which do not receive antithrombotic drugs, are 100% patent after 1 week

    Identifying the most productive breeding sites for malaria mosquitoes in The Gambia

    Get PDF
    BACKGROUND: Ideally larval control activities should be targeted at sites that generate the most adult vectors, thereby reducing operational costs. Despite the plethora of potential mosquito breeding sites found in the floodplains of the Gambia River, about 150 km from its mouth, during the rainy season, only a small proportion are colonized by anophelines on any day. This study aimed to determine the characteristics of larval habitats most frequently and most densely populated by anopheline larvae and to estimate the numbers of adults produced in different habitats. METHODS: A case-control design was used to identify characteristics of sites with or without mosquitoes. Sites were surveyed for their physical water properties and invertebrate fauna. The characteristics of 83 sites with anopheline larvae (cases) and 75 sites without (controls) were collected between June and November 2005. Weekly adult productivity was estimated with emergence traps in water-bodies commonly containing larvae. RESULTS: The presence of anopheline larvae was associated with high invertebrate diversity (Odds Ratio, OR 11.69, 95% CI 5.61-24.34, p < 0.001), the presence of emergent vegetation (OR 2.83, 95% CI 1.35-5.95, p = 0.006), and algae (at borderline significance; OR 1.87, 95% CI 0.96-3.618, p = 0.065). The density of larvae was reduced in sites that were larger than 100 m in perimeter (OR 0.151; 95% CI 0.060-0.381, p < 0.001), where water was tidal (OR 0.232; 95% CI 0.101-0.533, p = 0.001), vegetation shaded over 25% of the habitat (OR 0.352; 95% CI 0.136-0.911, p = 0.031) and water conductivity was above 2,000 muS/cm (OR 0.458; 95% CI 0.220-0.990, p = 0.048). Pools produced the highest numbers of Anopheles gambiae adults compared with rice fields, floodwater areas close to the edge of the floodplain or close to the river, and stream fringes. Pools were characterized by high water temperature and turbidity, low conductivity, increased presence of algae, and absence of tidal water. CONCLUSION: There are few breeding sites that produce a high number of adult vectors in the middle reaches of the river in The Gambia, whereas those with low productivity are larger in area and can be found throughout the rainy season. Even though risk factors could be identified for the presence and density of larvae and productivity of habitats, the results indicate that anti-larval interventions in this area of The Gambia cannot be targeted in space or time during the rainy season

    Coronary stenting with a new, radiopaque, balloon-expandable endoprosthesis in pigs

    No full text
    BACKGROUND. Intracoronary stents may be effective when used as "bail-out" devices for acute complications after percutaneous transluminal coronary angioplasty. Furthermore, preliminary reports have demonstrated some promising results with stents with regard to the reduction of restenosis. Several stent devices are available for preclinical and clinical evaluation. The use of these stainless-steel stents has been limited by poor visibility during fluoroscopy and thrombogenicity during the first days to weeks after implantation. We therefore investigated the immediate and short-term effects on arterial patency of a new, radiopaque, balloon-expandable coil stent in normal coronary arteries of pigs. METHODS AND RESULTS. In 10 animals, a stent was placed in two of the three epicardial coronary arteries. During the implantation procedure, the animals received heparin; after the procedure, no antithrombotic drugs were administered. After 1 week (five animals and 10 stents) or 4 weeks (five animals and 10 stents), repeat angiography was performed, followed by pressure-fixation of the coronary arteries for light and electron microscopic examination. Angiographic analysis revealed that all stented coronary segments were patent and without signs of intraluminal defects. Scanning electron microscopy showed complete endothelial covering of all stents within 7 days. Light microscopy showed a reduced tunica media locally under the stent wires, which resulted from exerted pressure. The neointima on top of the stent wires measured 56 microns (range, 42-88 microns) after 1 week and 139 microns (range, 84-250 microns) after 4 weeks. CONCLUSIONS. Results from this study show that this radiopaque endoprosthesis can be safely placed in normal coronary arteries of pigs. After 4 weeks, all stents were patent and there was no need for additional antithrombotic treatment, whereas neointimal proliferation was limited

    UvA-DARE (Digital Academic Repository) Synthesis, structure and spectroscopic properties of novel metal-metal bonded manganese-ruthenium complexes with t -diimine ligands. X-ray structure of [(CO)sMn-Ru(Me)(CO)a(a(N),a(N&apos;)-iPr-PyCa)] (iPr-PyCa -pyridine-2

    No full text
    Synthesis, structure and spectroscopic properties of novel metal-metal bonded manganeseruthenium complexes with alpha-diimine ligands. X-ray structure of [(CO)5Mn-Ru(Me)(CO)2(sigma(N&apos;)-iPr-PyCa)](iPr-PyCa = pyridine-2-carbaldehyde-N-isopropylimine) Oskam, A., &amp; Goubitz, K. (1995). Synthesis, structure and spectroscopic properties of novel metal-metal bonded manganese-ruthenium complexes with alpha-diimine ligands. X-ray structure of [(CO)5Mn-Ru(Me)(CO)2(sigma(N&apos;)-iPr-PyCa)](iPr-PyCa = pyridine-2-carbaldehyde-N-isopropylimine). Inorganica Chimica Acta, 232, 19-25. https://doi.org/10.1016/0020-1693(94)04360-8 General rights It is not permitted to download or to forward/distribute the text or part of it without the consent of the author(s) and/or copyright holder(s), other than for strictly personal, individual use, unless the work is under an open content license (like Creative Commons). Disclaimer/Complaints regulations If you believe that digital publication of certain material infringes any of your rights or (privacy) interests, please let the Library know, stating your reasons. In case of a legitimate complaint, the Library will make the material inaccessible and/or remove it from the website. Please Ask the Library: https://uba.uva.nl/en/contact, or a letter to: Library of the University of Amsterdam, Secretariat, Singel 425, 1012 WP Amsterdam, The Netherlands. You will be contacted as soon as possible. Synthesis, structure and spectroscopic properties of novel metal-metal bonded manganese-ruthenium complexes with t -diimine ligands. X-ray structure of [(CO)sMn-Ru(Me) Abstract The synthesis and spectroscopy of the complexes [(CO)sMn-Ru(Me)(CO)2(a-diimine)] (a-diimine=N,N&apos;-diisopropyl-l,4-diaza-l,3-butadiene (iPr-DAB), pyridine-2-carbaldehyde-N-isopropylimine (iPr-PyCa)) are reported. The metal fragments are bonded to each other by an uncommon manganese-ruthenium bond. The single crystal X-ray structure has been determined. The purple crystals of [(CO)sMn-Ru(Me)(CO)2(iPr-PyCa)] are monoclinic, space group P21/n, Z=4, with unit cell dimensions a = 9.6297(7), b = 20.923(1), c = 10.166(1) ~ and fl = 92.190(8) °. The structure refinement converged to R = 0.035 for 3277 observed reflections. Both complexes show a strong, solvatochromic absorption band in the visible region, which is assigned to Ru (d,~)~a-diimine (~-*) transitions. In agreement with this assignment, the Raman spectra show resonance enhancement of Raman intensity for vs(CO) and vs(CN) of the Ru(Me)(CO)2(a-diimine) fragment

    Arterial stenting with self-expandable and balloon-expandable endoprostheses

    No full text
    Coronary angioplasty is complicated by acute occlusion (within 24 hours) and late restenosis (within 6 months) in 2-5% and 20-40% of the cases, respectively. Vascular endoprostheses (stents) may provide the cardiologist with a solution to some of these complications. Several stent-devices are now available for experimental and clinical evaluation. In this study we describe our experience with two metallic stents in normal arteries of swine. Self-expandable, stainless steel stents (3.5 mm diameter) were implanted in 17 peripheral arteries, eight of which were deendothelialized by prior balloon angioplasty. Following implantation, the animals received antithrombotic therapy with acenocoumarol and aspirin (8 stents), or aspirin alone (9 stents). After 1 week repeat angiography was performed, which showed patency of all stented arteries. Microscopy showed complete covering by neointima, 80 μm in thickness. This self-expandable stent (SES) and a balloon-expandable stent (BES), constructed of tantalum, were implanted in normal coronary arteries. SES (3.0 and 3.5 mm) receiving animals were treated with coumadines (10 stents) or received no antithrombotic treatment (16 stents) after implantation. BES receiving animals were also not treated (10 stents). Three untreated animals with SES died suddenly within 48 hours. Postmortem examination showed partial or complete thrombosis of all six stents in these animals, resulting in a patency rate of 62% after 1 week. All animals with SES, which were treated with coumadines, and all animals with BES (untreated) had patent stents after one week. It is concluded that SES implanted in normal coronary arteries of pigs, which do not receive additional antithrombotic treatment, show a 38% occlusion rate within 48 hours, but show 100% patency after 1 week, when the animals are treated with coumadines. BES implanted in normal coronary arteries of pigs, which do not receive antithrombotic drugs, are 100% patent after 1 week.</p
    corecore