26 research outputs found

    Effect of aging on esophageal motility in patients with and without GERD

    Get PDF
    Background/Aims: The impact of aging on esophageal motility is not completely understood. This study aims at assessing 1) whether degeneration of esophageal body motility occurs with age and 2) whether this development is influenced by gastroesophageal reflux disease (GERD)

    Effect of aging on esophageal motility in patients with and without GERD

    Get PDF
    Background/Aims: The impact of aging on esophageal motility is not completely understood. This study aims at assessing 1) whether degeneration of esophageal body motility occurs with age and 2) whether this development is influenced by gastroesophageal reflux disease (GERD)

    Obesity and Gastroesophageal Reflux: Quantifying the Association Between Body Mass Index, Esophageal Acid Exposure, and Lower Esophageal Sphincter Status in a Large Series of Patients with Reflux Symptoms

    Get PDF
    Obesity and gastroesophageal reflux disease (GERD) are increasingly important health problems. Previous studies of the relationship between obesity and GERD focus on indirect manifestations of GERD. Little is known about the association between obesity and objectively measured esophageal acid exposure. The aim of this study is to quantify the relationship between body mass index (BMI) and 24-h esophageal pH measurements and the status of the lower esophageal sphincter (LES) in patients with reflux symptoms. Data of 1,659 patients (50% male, mean age 51 ± 14) referred for assessment of GERD symptoms between 1998 and 2008 were analyzed. These subjects underwent 24-h pH monitoring off medication and esophageal manometry. The relationship of BMI to 24-h esophageal pH measurements and LES status was studied using linear regression and multiple regression analysis. The difference of each acid exposure component was also assessed among four BMI subgroups (underweight, normal weight, overweight, and obese) using analysis of variance and covariance. Increasing BMI was positively correlated with increasing esophageal acid exposure (adjusted R 2 = 0.13 for the composite pH score). The prevalence of a defective LES was higher in patients with higher BMI (p < 0.0001). Compared to patients with normal weight, obese patients are more than twice as likely to have a mechanically defective LES [OR = 2.12(1.63–2.75)]. An increase in body mass index is associated with an increase in esophageal acid exposure, whether BMI was examined as a continuous or as a categorical variable; 13% of the variation in esophageal acid exposure may be attributable to variation in BMI

    Modular step-up approach to robot-assisted transthoracic esophagectomy-experience of a German high volume center

    No full text
    Background: The use of robotic technology in general surgery is rapidly increasing in Europe. Aim of this study is to evaluate the introduction of new robotic technologies in a center of excellence for upper gastrointestinal surgery. Methods: A standardized teaching protocol of a complete OR team was performed in simulation and animal models at the Center for the Future of Surgery (San Diego CA, USA) and IRCAD (Strasbourg, France) to receive certification as console surgeons. Starting 02/2017 the daVinci Xi and Stryker ICG laparoscopy systems were introduced at our academic center (certified center of excellence for surgery of the upper gastrointestinal tract, n>300 upper gastrointestinal cases/year). After simple training procedures based on our minimally invasive expertise were performed, difficulty was increased based on a modular step up approach to finally perform robotic assisted transthoracic Ivor Lewis esophagectomy. Results: A total of 70 patients (9 females) fulfilled inclusion criteria to our study. Robotic assisted esophagectomy was divided into six modules. Level of difficulty was increased based on our modular step up approach without quality compromises. There were no intraoperative complications and no unplanned conversions to open surgery. Two surgeons were able to sequentially train and perform a completely robotic transthoracic esophagectomy using this modular approach without a substantial learning curve. A total of ten esophagectomies per surgeon were necessary to complete all modules in one case. Conclusions: The standardized training protocol and the University of Cologne modular step up approach allowed safe introduction of the new technology used. All cases were performed safely without operation-associated complications

    Incidence and management of chylothorax after Ivor Lewis esophagectomy for cancer of the esophagus

    No full text
    Objective: Chylothorax is a major complication after esophagectomy. As recent studies refer to heterogeneous patient cohorts and surgical procedures, this study was conducted to report the incidence and evaluate the optimal management of chylous fistula in patients treated with transthoracic esophagectomy and 2 -field lymphadenectomy for esophageal cancer. Methods: From January 2005 to December 2013, a total of 906 patients underwent transthoracic esophageal resection for esophageal carcinoma at our institution. En bloc esophagectomy was performed with routine supradiaphragmatic ligation of the thoracic duct. The incidence of chylothorax, and associated morbidity and mortality, were analyzed, and subsequent therapeutic management was reviewed. Results: Chylothorax after Ivor Lewis esophagectomy was observed in 17 (1.9%) patients. Fifteen patients required surgical intervention with rethoracotomy and repeat duct ligation. Thoracic duct ligation was successful in all patients. Two patients died within 90 days after primary esophageal resection. The median time between initial tumor resection and rethoracotomy was 13 days. Average daily chest-tube output at time of reoperation was 1900 mL. In 2 patients, pleural effusion did not exceed 1000 mL per day. In these cases, conservative management with additional thoracic drainage and total parenteral nutrition led to complete resolution of chylous fistula. Conclusions: Occurrence of chylothorax after prophylactic thoracic duct ligation during transthoracic esophagectomy for esophageal cancer is rare. In patients with high -output chylous fistula, an early rethoracotomy with repeat ligation of the thoracic duct is safe and helps to shorten recovery time. In cases of low-volume drainage, a conservative approach is feasible

    Ultrasound-guided lymphangiography and interventional embolization of chylous leaks following esophagectomy

    No full text
    Postoperative chylothorax is a serious complication after transthoracic esophagectomy, and is associated with major morbidity due to dehydration and malnutrition. For patients with high-output fistula, re-thoracotomy with ligation of the thoracic duct is the treatment of choice. Radiologic interventional management is an innovative procedure that has the potential to replace surgery in the treatment algorithm

    Ultrasound-guided lymphangiography and interventional embolization of chylous leaks following esophagectomy

    No full text
    Objectives: Postoperative chylothorax is a serious complication after transthoracic esophagectomy, and is associated with major morbidity due to dehydration and malnutrition. For patients with high-output fistula, rethoracotomy with ligation of the thoracic duct is the treatment of choice. Radiologic interventional management is an innovative procedure that has the potential to replace surgery in the treatment algorithm. Methods: Four patients with high-output chylous leaks following esophagectomy are presented. Ultrasound-guided lymphangiography with embolization of the thoracic duct and/or disruption of the cisterna chyli was performed to occlude the leakage site. Radiologic interventions and procedure-related outcomes are described in detail. Results: In all four patients, ultrasound-guided lymphangiography of the groin with injection of Lipiodol was able to detect and visualize the leakage site in the lower mediastinum. In three patients, the leak could be successfully occluded by Lipiodol embolization. In one patient, embolization failed and the disruption technique was successfully performed. No procedure-related complications were observed. Conclusions: In case of a postoperative chylothorax, radiologic intervention is feasible and safe. The procedure is indicated for high-output chylous fistulas after esophagectomy, and should be applied early after the diagnosis of this postoperative complication

    Robot-assisted repair of hiatal hernia: Advantages and disadvantages in comparison to conventional laparoscopic repair: A literature review

    No full text
    The laparoscopic fundoplication has proven to be the standard technique of antireflux surgery and hiatal hernia (HH) repair over the last decade. However, robot-assisted surgery is more and more implemented in daily practice. Several studies have proven the feasibility and safety of robot-assisted HH repair and antireflux surgery. Both approaches seem to be similar regarding perioperative and postoperative complications, length of hospital stay, postoperative symptoms, and quality of life, as well as objective assessment of gastric acid exposure. Nevertheless, high total costs as well as a considerably longer total operating time of robot-assisted surgery need to be considered. The role of robot-assisted surgery in complex cases is promising but needs to be evaluated. Eventually, the decision regarding the technique used should be based on the surgeon’s discretion and experience

    Percutaneous Endoscopic Gastrostomy in Direct Puncture Technique: When, Why and How?

    No full text
    Background: Percutaneous endoscopic gastrostomy (PEG) placed in the pull through (PT) technique is a common procedure to restore enteral feeding in patients with swallowing disorders. Limitations of this technique are patients with obstruction of the pharynx or esophagus or with an esophageal stent. We report our experience with the direct puncture (DP) PEG device. Methods: We included 154 patients (55 women). One hundred forty patients had cancer. After passing the endoscope into the stomach, 4 gastropexies were performed with a gastropexy device and the PEG was placed with the introducer method. After 1 month, the sutures were removed and a constant gastrocutaneous fistula had been created and the new catheter could be placed safely. Results: The DP PEG was successfully placed in all patients. Overall complication rate was 11% (minor: 6%, major: 5%). The most common event was tube dislocation (40 cases). In 5 cases of dislocation, this resulted in a major complication with injuring the gastric wall and the necessity for surgical treatment. Conclusions: The DP PEG system is safe, and can be used in cases in which a standard PT PEG is not feasible. To avoid dislocation, strict adherence to a post-interventional protocol is highly recommended. (C) 2016 S. Karger AG, Base

    Software improvement for evaluation of laryngopharyngeal pH testing (Restech) - a comparison between DataView 3 and 4

    Get PDF
    BACKGROUND When gastroesophageal reflux contents reach above the upper esophageal sphincter, patients may, in addition to typical reflux symptoms, present with atypical, extraesophageal symptoms related to laryngopharyngeal reflux (LPR). Surgical treatment of LPR has shown to lead to 70% symptom improvement, however no gold standard for the diagnosis of LPR exists. In 2007, the Restech Dx-pH was released as a valid method to measure acid exposure above the upper esophageal sphincter. Recently, a new software update was introduced for analysis of measured pH data and calculation of composite scores. The effect of the changes applied to the new software version have not yet been analyzed. AIM To compare results generated by DataView 3 to the most recently released DataView 4. METHODS All patients with gastroesophageal reflux disease symptoms were seen in a specialized surgical outpatient clinic for gastrointestinal function testing. Retrospective chart review was performed of all patients presenting with suspected gastroesophageal reflux disease and extraesophageal reflux symptoms, who underwent laryngopharyngeal pH monitoring using the Restech Dx-pH system (Respiratory Technology Corp., Houston, TX, United States) and simultaneous esophageal pH monitoring. DataView 3 and DataView 4 were used to evaluate Restech studies obtained. Diary entries such as mealtimes, supine and upright periods, and symptoms were entered manually to ensure accuracy and precise conversion of data between both software versions. Pairedttest was performed for statistical analysis of results. RESULTS A total of 174 patients (63.8% female) met inclusion criteria, all suffering from extraesophageal reflux symptoms as well as typical gastroesophageal reflux disease symptoms. Mean RYAN score upright was 48.77 in DataView 3 compared to 22.17 in DataView 4, showing a significant difference (P-a= 0.0001). Similar results were shown for supine period (mean RYAN Score DataView 3 5.29vs1.42 in DataView 4,(c) P= 0.0001). For upright periods 80 patients showed a decrease of value of the RYAN score with a mean of -58.9 (mean 51.1% decrease). For supine position 25 patients showed a decrease of value of the RYAN score with a mean of -15.13 [range (-153.44)-(-0.01)], which equals a mean decrease of value of 44.5%. Ten patients showed no oropharyngeal acid exposure in DataView 3, but mild/moderate (n= 7) or severe (n= 3) acid exposure in DataView 4. Correlation with positive esophageal pH measurement was improved in all 10 patients. CONCLUSION Results of both software versions cannot be compared to each other. However, our data suggests that DataView 4 may be an improvement of the Restech pH measurement in the evaluation of LPR
    corecore