3,397 research outputs found
Fabrication and characterization of high current-density, submicron, NbN/MgO/NbN tunnel junctions
At near-millimeter wavelengths, heterodyne receivers based on SIS tunnel junctions are the most sensitive available. However, in order to scale these results to submillimeter wavelengths, certain device properties should be scaled. The tunnel-junction's current density should be increased to reduce the RC product. The device's area should be reduced to efficiently couple power from the antenna to the mixer. Finally, the superconductor used should have a large energy gap to minimize RF losses. Most SIS mixers use Nb or Pb-alloy tunnel junctions; the gap frequency for these materials is approximately 725 GHz. Above the gap frequency, these materials exhibit losses similar to those in a normal metal. The gap frequency in NbN films is as-large-as 1440 GHz. Therefore, we have developed a process to fabricate small area (down to 0.13 sq microns), high current density, NbN/MgO/NbN tunnel junctions
Large Area Crop Inventory Experiment (LACIE). USSR spring and winter wheat models, addendum
There are no author-identified significant results in this report
The millimeter-wave properties of superconducting microstrip lines
We have developed a novel technique for making high quality measurements of the millimeter-wave properties of superconducting thin-film microstrip transmission lines. Our experimental technique currently covers the 75-100 GHz band. The method is based on standing wave resonances in an open ended transmission line. We obtain information on the phase velocity and loss of the microstrip. Our data for Nb/SiO/Nb lines, taken at 4.2 K and 1.6 K, can be explained by a single set of physical parameters. Our preliminary conclusion is that the loss is dominated by the SiO dielectric, with a temperature-independent loss tangent of 5.3 ± 0.5 x 10^(-3) for our samples
Factors Influencing Influenza Vaccination Rates Among Rural Ontario Paramedics
Introduction. Influenza vaccination rates have traditionally been very low among healthcare workers (HCWs) however; very few studies have examined vaccination rates andmotivators among paramedics.
Objectives. The Health Belief Model (HBM) (Rosenstock,1974) was used as a guideline in this study to better understand the motivators and barriers to flu vaccination among rural Ontario paramedics. This group represents a considerable proportion of the HCW community, yet it has been virtually omitted from previous research.
Methods. Through the use of self-report questionnaires, and using the HBM as a guideline, a graphical representation of the decision-making process regarding flu vaccination was generated. The sample included 99 independent responses received from 5 rural Ontario Emergency Medical Services (EMS): Bruce County EMS; County of Renfrew Paramedic Services; Haldimand County EMS; Haliburton County (Muskoka) EMS; and Perth County EMS. Univariate, Bivariate and Logistic Regression Analyses were conducted to evaluate data.
Results. Living arrangement (OR=4.80, 95%CI: 1.13-20.46) was found to directly affect vaccination rates within this group. Male gender (OR=2.50, 95%CI: 0.62-10.05), less than 5 years of service (OR=5.00, 95%CI: 0.54-46.72) and more than 20 years of service (OR=5.50, 95%CI: 0.59-51.19) trended toward higher rates of vaccination. There was no effect of age or level of education. Increased convenience has been previously cited as a way to improve vaccination rates, however; it appeared only to assist in improving rates for individuals already considering vaccination.
Conclusions. Increased Potential Benefits and Cues to Action are two dimensions of the HBM that could affect a change in vaccination status. This increased knowledge is useful in the development of targeted vaccine uptake initiatives that could lead to increased rates of vaccination among paramedics, HCWs and the community at large
Insulator interface effects in sputterâdeposited NbN/MgO/NbN (superconductorâinsulatorâsuperconductor) tunnel junctions
All refractory, NbN/MgO/NbN (superconductorâinsulatorâsuperconductor) tunnel junctions have been fabricated by in situ sputter deposition. The influence of MgO thickness (0.8â6.0 nm) deposited under different sputtering ambients at various deposition rates on currentâvoltage (IâV) characteristics of smallâarea (30Ă30 ÎŒm) tunnel junctions is studied. The NbN/MgO/NbN trilayer is deposited in situ by dc reactive magnetron (NbN), and rf magnetron (MgO) sputtering, followed by thermal evaporation of a protective Au cap. Subsequent photolithography, reactive ion etching, planarization, and top contact (Pb/Ag) deposition completes the junction structure. Normal resistance of the junctions with MgO deposited in Ar or Ar and N2 mixture shows good exponential dependence on the MgO thickness indicating formation of a pinâholeâfree uniform barrier layer. Further, a postdeposition in situ oxygen plasma treatment of the MgO layer increases the junction resistance sharply, and reduces the subgap leakage. A possible enrichment of the MgO layer stoichiometry by the oxygen plasma treatment is suggested. A sumgap as high as 5.7 mV is observed for such a junctio
Development of Low Noise THz SIS Mixer Using an Array of Nb/Al-AlN/NbTiN Junctions
We report the development of a low noise and broadband SIS mixer aimed for 1 THz channel of the Caltech Airborne Submillimeter Interstellar Medium Investigations Receiver (CASIMIR), designed for the Stratospheric Observatory for Infrared Astronomy, (SOFIA). The mixer uses an array of two 0.24 mum^2 Nb/Al-AlN/NbTiN SIS junctions with the critical current density of 30-50 kA/cm^2 . An on-chip double slot planar antenna couples the mixer circuit with the telescope beam. The mixer matching circuit is made with Nb and gold films. The mixer IF circuit is designed to cover 4-8 GHz band. A test receiver with the new mixer has a low noise operation in 0.87-1.12 THz band. The minimum receiver noise measured in our experiment is 353 K (Y = 1.50). The receiver noise corrected for the loss in the LO injection beam splitter is 250 K. The combination of a broad operation band of about 250 GHz with a low receiver noise makes the new mixer a useful element for application at SOFIA
Abundance of small individuals influences the effectiveness of processing techniques for deep-sea nematodes
Nematodes are the most abundant metazoans of deep-sea benthic communities, but knowledge of their distribution is limited relative to larger organisms. Whilst some aspects of nematode processing techniques, such as extraction, have been extensively studied, other key elements have attracted little attention. We compared the effect of (1) mesh size (63, 45, and 32 ÎŒm) on estimates of nematode abundance, biomass, and body size, and (2) microscope magnification (50 and 100Ă) on estimates of nematode abundance at bathyal sites (250-3100 m water depth) on the Challenger Plateau and Chatham Rise, south-west Pacific Ocean. Variation in the effectiveness of these techniques was assessed in relation to nematode body size and environmental parameters (water depth, sediment organic matter content, %silt/clay, and chloroplastic pigments). The 63-ÎŒm mesh retained a relatively low proportion of total nematode abundance (mean ±SD = 55 ±9%), but most of nematode biomass (90 ± 4%). The proportion of nematode abundance retained on the 45-ÎŒm mesh in surface (0-1 cm) and subsurface (1-5 cm) sediment was significantly correlated (P < 0.01) with %silt/clay (RÂČ = 0.39) and chloroplastic pigments (RÂČ = 0.29), respectively. Variation in median nematode body weight showed similar trends, but relationships between mean nematode body weight and environmental parameters were either relatively weak (subsurface sediment) or not significant (surface sediment). Using a low magnification led to significantly lower (on average by 43%) nematode abundance estimates relative to high magnification (P < 0.001), and the magnitude of this difference was significantly correlated (P < 0.05) with total nematode abundance (RÂČp = 0.53) and the number of small (†250 ÎŒm length) individuals (RÂČp = 0.05). Our results suggest that organic matter input and sediment characteristics influence the abundance of small nematodes in bathyal communities. The abundance of small individuals can, in turn, influence abundance estimates obtained using different mesh sizes and microscope magnifications
Low Noise 1 THzâ1.4 THz Mixers Using Nb/Al-AlN/NbTiN SIS Junctions
We present the development of a low noise 1.2 THz and 1.4 THz SIS mixers for heterodyne spectrometry on the Stratospheric Observatory For Infrared Astronomy (SOFIA) and Herschel Space Observatory. This frequency range is above the limit for the commonly used Nb quasi particle SIS junctions, and a special type of hybrid Nb/AlN/NbTiN junctions has been developed for this project.We are using a quasi-optical mixer design with two Nb/AlN/NbTiN junctions with an area of 0.25 ”m^2. The SIS junction tuning circuit is made of Nb and gold wire layers. At 1.13 THz the minimum SIS receiver uncorrected noise temperature is 450 K. The SIS receiver noise corrected for the loss in the LO coupler and in the cryostat optics is 350â450 K across 1.1â1.25 THz band. The receiver has a uniform sensitivity in a full 4â8 GHz IF band.
The 1.4 THz SIS receiver test at 1.33â1.35 THz gives promising results, although limited by the level of available LO power. Extrapolation of the data obtained with low LO power level shows a possibility to reach 500 K DSB receiver noise using already existing SIS mixer
Measurements of noise in Josephson-effect mixers
We present new heterodyne receiver results obtained at 100 GHz using resistively-shunted Nb and NbN tunnel junctions. In addition, we have carried out accurate measurements of the available noise power of these devices at the L-band (1.5 GHz) IF frequency. Both the heterodyne and the output noise measurements show that the noise of these devices can be a factor of five or more higher than that predicted by the simple current-biased RSJ model. The noise approaches the appropriate thermal or thermal and shot noise limits for bias voltages where the nonlinearity is not strong (i.e., V>ICRN), but as expected from the RSJ model, can be significantly higher at the low voltages where the mixers are typically biased. The bias voltage dependence of the noise shows structure which is associated with resonances in the RF embedding circuit. Surprisingly, we find that changes in the high-frequency (100 GHz) impedance presented to the junction can dramatically affect the magnitude and voltage dependence of the low-frequency (1.5 GHz) noise. This emphasizes the necessity of very closely matching the junction to free space over a wide frequency range
- âŠ