126 research outputs found
Surgical management of early-onset scoliosis: indications and currently available techniques
Early-onset scoliosis (EOS) is a heterogeneous group of spinal deformities affecting children under the age of 10 years of which the aetiology, natural history and treatment options vary considerably. In progressive EOS, treatment is based on exhausting conservative measures (casting or bracing) to halt curve progression while allowing for continuous growth of the spine and chest development. Early spinal fusion leads to loss of longitudinal spinal growth and restriction of cardiopulmonary function. In rapidly progressive curves that have failed conservative treatment a range of ‘growth-friendly’ surgical techniques have been developed to control curve deterioration. The indications and characteristics of distraction-based or compression-based methods, growth guidance and promising new techniques are discussed according to aetiology of EOS. Definitive spinal fusion remains reserved for patients ideally towards the end of their spinal growth and for short-segment treatment in congenital scoliosis
The potential of spring distraction to dynamically correct complex spinal deformities in the growing child
Purpose: Current treatment of progressive early onset scoliosis involves growth-friendly instrumentation if conservative treatment fails. These implants guide growth by passive sliding or repeated lengthenings. None of these techniques provide dynamic correction after implantation. We developed the spring distraction system (SDS), by using one or multiple compressed springs positioned around a standard sliding rod, to provide active continuous distraction of the spine to stimulate growth and further correction. The purpose of this study was to determine feasibility and proof of concept of the SDS. Methods: We developed a versatile, dynamic spring distraction system for patients who would benefit from active continuous distraction. This prospective case series evaluates four patients with exceptional and progressive congenital spine deformities. Results: Four patients had a mean age of 6.8 years at surgery with a mean follow-up of 36 months (range 25–45). The mean progressive thoracic lordosis, which was the reason for initiating surgical treatment in two patients, changed from 32° lordosis preoperatively to 1° kyphosis post-operatively. During follow-up, this further improved to 32° thoracic kyphosis. In the two other patients, with cervicothorcacic scoliosis, the main coronal curve improved from 79° pre-operatively to 56° post-operatively and further improved to 42°. The mean T1-S1 spine growth during follow-up for all patients was 1.3 cm/year. There was one reoperation because of skin problems and no device-failures. Conclusion: These early results show the feasibility and the proof of concept of spring-based distraction as a dynamic growth-enhancing system with the potential of further correction of the deformity after implantation
Громадська робота як чинник повсякденного життя вчителя
Treatment and reconstruction of large bone defects, delayed unions, and nonunions is challenging and has resulted in an ongoing search for novel tissue-engineered therapies. Bone morphogenetic protein-2 (BMP-2) gene therapy is a promising strategy to provide sustained production of BMP-2 locally. Alginate polymer-based nonviral gene therapy with BMP-2 plasmid DNA (pBMP-2) in constructs with multipotent mesenchymal stromal cells (MSCs) has resulted in prolonged gene expression and bone formation in vivo. To further translate this technology toward larger animal models, important issues remain to be investigated, such as the necessity of seeded cells as a target for gene therapy. For that purpose, a large animal-screening model in an orthotopic location, with fully separated chambers, was investigated. Four cylinder-shaped implants were placed in the iliac crests of ten goats. Polycaprolactone tubes around each implant allowed bone ingrowth from the underlying bone and bone marrow and ensured separation of the experimental conditions. An empty tube showed low levels of spontaneous bone ingrowth, and implantation of autologous bone indicated proper bone function with respect to remodeling and resorption. Control ceramic scaffolds were compared to scaffolds containing pBMP-2 either or not combined with seeded MSCs. Fluorochrome incorporation evaluated at 3, 6, and 9 weeks and histomorphometry at 12 weeks after implantation revealed clear differences between the groups, with pBMP-2 combined with MSCs being the most effective. The BMP-2 was demonstrated in a variety of bone-residing cells through immunohistochemistry. Further analysis indicated that multinucleated giant cells might have an important role in transgene expression. Taken together, this work introduces a large animal model for studying bone formation at multiple sites simultaneously in an orthotopic location. The model appeared robust, showed no neighboring effects, and demonstrated effectivity of combined cell and gene therapy
Схемотехническое моделирование и синтез активных СВЧ-фильтров на полевых транзисторах Шоттки
Разработаны схемы активных СВЧ-фильтров, пригодных для исполнения в виде гибридной или полупроводниковой микросхемы
The three-dimensional coupling mechanism in scoliosis and its consequences for correction
Introduction: In idiopathic scoliosis, the anterior spinal column has rotated away from the midline and has become longer through unloading and expansion of the intervertebral discs. Theoretically, extension of the spine in the sagittal plane should provide room for this longer anterior spinal column, allowing it to swing back towards the midline in the coronal and axial plane, thus reducing both the Cobb angle and the apical vertebral rotation. Methods: In this prospective experimental study, ten patients with primary thoracic adolescent idiopathic scoliosis (AIS) underwent MRI (BoneMRI and cVISTA sequences) in supine as well as in an extended position by placing a broad bolster, supporting both hemi-thoraces, under the scoliotic apex. Differences in T4–T12 kyphosis angle, coronal Cobb angle, vertebral rotation, as well as shape of the intervertebral disc and shape and position of the nucleus pulposus, were analysed and compared between the two positions. Results: Extension reduced T4–T12 thoracic kyphosis by 10° (p < 0.001), the coronal Cobb angle decreased by 9° (p < 0.001) and vertebral rotation by 4° (p = 0.036). The coronal wedge shape of the disc significantly normalized and the wedged and lateralized nucleus pulposus partially reduced to a more symmetrical position. Conclusion: Simple extension of the scoliotic spine leads to a reduction of the deformity in the coronal and axial plane. The shape of the disc normalizes and the eccentric nucleus pulposus partially moves back to the midline
Spring distraction system for dynamic growth guidance of early onset scoliosis: two-year prospective follow-up of 24 patients
BACKGROUND: Current surgical treatment options for early onset scoliosis (EOS), with distraction- or growth-guidance implants, show limited growth and high complication rates during follow-up. We developed a novel implant concept, which uses compressed helical springs positioned around the rods of a growth-guidance construct. This spring distraction system (SDS) provides continuous corrective force to stimulate spinal growth, can be easily contoured, and can be used with all standard spinal instrumentation systems. PURPOSE: To assess curve correction and -maintenance, spinal growth, complication rate, and health-related quality of life following SDS treatment. STUDY DESIGN: Prospective cohort study. PATIENT SAMPLE: All skeletally immature EOS patients with an indication for growth-friendly surgery and without bone- or soft tissue weakness were eligible to receive SDS. For this study, all included patients with at least 2-year follow-up were analyzed. OUTCOME MEASURES: Coronal Cobb angle, sagittal parameters, T1-T12, T1-S1, and instrumented (ie, bridged segment) spinal height and freehand length, complications and re-operations, and the 24-Item Early Onset Scoliosis Questionnaires (EOSQ-24) score. METHODS: All primary- and conversion patients (conversion from failed other systems) with SDS and ≥2 years follow-up were included. Radiographic parameters were compared preoperatively, postoperatively and at latest follow-up. Spinal length increase was expressed as mm/year. RESULTS: Twenty-four skeletally immature EOS patients (18 primary and 6 conversion cases) were included. There were five idiopathic, seven congenital, three syndromic, and nine neuromuscular EOS patients. Mean age at implantation was 9.1 years (primary: 8.4; conversion: 11.2). Major curve improved from 60.3° to 35.3°, and was maintained at 40.6° at latest follow-up. Mean spring length increase during follow-up was 10.4 mm/year. T1-S1 height increased 9.9mm/year and the instrumented segment height showed a mean increase of 0.7 mm/segment/year. EOSQ-24 scores dropped after surgery from 75.6 to 67.4 but recovered to 75.0 at latest follow-up. In total, 17 reoperations were performed. Ten reoperations were performed to treat 9 implant-related complications. In addition, 7 patients showed spinal growth that exceeded expected growth velocity; their springs were retensioned during a small reoperation. CONCLUSION: The 2-year follow-up results from this prospective cohort study indicate that the concept of spring distraction may be feasible as an alternative to current growing spine solutions. Curve correction and growth could be maintained satisfactory without the need for repetitive lengthening procedures. However, as in all growth-friendly implants, complications and reoperations could not be prevented, which emphasizes the need for further improvement
Induction of a representative idiopathic-like scoliosis in a porcine model using a multidirectional dynamic spring-based system
BACKGROUND CONTEXT: Scoliosis is a 3D deformity of the spine in which vertebral rotation plays an important role. However, no treatment strategy currently exists that primarily applies a continuous rotational moment over a long period of time to the spine, while preserving its mobility. We developed a dynamic, torsional device that can be inserted with standard posterior instrumentation. The feasibility of this implant to rotate the spine and preserve motion was tested in growing mini-pigs. PURPOSE: To test the quality and feasibility of the torsional device to induce the typical axial rotation of scoliosis while maintaining growth and mobility of the spine. STUDY DESIGN: Preclinical animal study with 14 male, 7 month old Gottingen mini-pigs. Comparison of two scoliosis induction methods, with and without the torsional device, with respect to 3D deformity and maintenance of the scoliosis after removal of the implants. METHODS: Fourteen mini-pigs received either a unilateral tether-only (n=6) or a tether combined with a contralateral torsional device (n=8). X-rays and CT-scans were made post-operative, at 8 weeks and at 12 weeks. Flexibility of the spine was assessed at 12 weeks. In 3 mini-pigs per condition, the implants were removed and the animals were followed until no further correction was expected. RESULTS: At 12 weeks the tether-only group yielded a coronal Cobb angle of 16.8±3.3°For the tether combined with the torsional device this was 22.0±4.0°. The most prominent difference at 12 weeks was the axial rotation with 3.6±2.8° for the tether-only group compared to 18.1±4.6° for the tether-torsion group. Spinal growth and flexibility remained normal and comparable for both groups. After removal of the devices, the induced scoliosis reduced by 41% in both groups. There were no adverse tissue reactions, implant complications or infections. CONCLUSION: The present study indicates the ability of the torsional device combined with a tether to induce a flexible idiopathic-like scoliosis in mini-pigs. The torsional device was necessary to induce the typical axial rotation found in human scoliosis. Clinical significance: The investigated torsional device could induce apical rotation in a flexible and growing spine. Whether this may be used to reduce a scoliotic deformity remains to be investigated
Morphologic Changes of the Intervertebral Disk During Growth
Study Design. Cross-sectional. Objective. The aim of this study was to describe morphologic changes of the annulus fibrosus (AF) and nucleus pulposus (NP) in children during growth using magnetic resonance imaging. Summary of Background Data. Little is known of intervertebral disk (IVD) maturation as opposed to degeneration, such as changes in relative AF/NP proportions and orientation during growth. Studies suggest that IVD plays a role in the etiology of pediatric spinal deformities. Therefore, understanding the morphologic development of the AF and NP during growth is key. Materials and Methods. An existing database of children aged 0 to 18 that had magnetic resonance imaging for indications unrelated to the spine were analyzed. The AF/NP were segmented semiautomatically from T1 to L5. The parameters: mean IVD height, cross-sectional area, slenderness (height/width ratio), volume (ratio), and relative position of the centroid of the NP within the IVD in three directions (x, y, z) were extracted, and compared between age, sex, and spinal level. Results. IVD height increased modestly and predominantly in the low-thoracic and lumbar spine during the first 5 to 10 years of life. Cross-sectional area and thus volume increased steadily at all levels throughout growth. IVD slenderness decreased sharply in the first years of life and remains relatively stable throughout the remainder of growth. IVDs were smaller and more slender in females, especially in the mid-thoracic spine at early adolescence. In the upper-thoracic and mid-thoracic spine the NP comprises 10% to 12% of total IVD volume during growth, this percentage increases in the low-thoracic and lumbar spine towards 20% to 25%. In the anterior-posterior direction, the position of the nucleus increasingly shifts with age, possibly in line with the developing sagittal profile of the spine. Conclusion. This study describes the development of thoracic and lumbar IVDs during growth and may be used as a reference for future studies on the role of IVD in the etiology of disk-related disorders
- …