692 research outputs found

    Simultaneous existence of two spin-wave modes in ultrathin Fe/GaAs(001) films studied by Brillouin Light Scattering: experiment and theory

    Full text link
    A double-peaked structure was observed in the {\it in-situ} Brillouin Light Scattering (BLS) spectra of a 6 \AA thick epitaxial Fe/GaAs(001) film for values of an external magnetic field HH, applied along the hard in plane direction, lower than a critical value Hc0.9H_c\simeq 0.9 kOe. This experimental finding is theoretically interpreted in terms of a model which assumes a non-homogeneous magnetic ground state characterized by the presence of perperpendicular up/down stripe domains. For such a ground state, two spin-wave modes, namely an acoustic and an optic mode, can exist. Upon increasing the field the magnetization tilts in the film plane, and for HHcH \ge H_{c} the ground state is homogeneous, thus allowing the existence of just a single spin-wave mode. The frequencies of the two spin-wave modes were calculated and successfully compared with the experimental data. The field dependence of the intensities of the corresponding two peaks that are present in the BLS spectra was also estimated, providing further support to the above-mentioned interpretation.Comment: Shortened version (7 pages). Accepted for publication in Physical Review

    Magnetoresistance, Micromagnetism, and Domain Wall Scattering in Epitaxial hcp Co Films

    Full text link
    Large negative magnetoresistance (MR) observed in transport measurements of hcp Co films with stripe domains were recently reported and interpreted in terms of a novel domain wall (DW) scattering mechanism. Here detailed MR measurements, magnetic force microscopy, and micromagnetic calculations are combined to elucidate the origin of MR in this material. The large negative room temperature MR reported previously is shown to be due to ferromagnetic resistivity anisotropy. Measurements of the resistivity for currents parallel (CIW) and perpendicular to DWs (CPW) have been conducted as a function of temperature. Low temperature results show that any intrinsic effect of DWs scattering on MR of this material is very small compared to the anisotropic MR.Comment: 5 pages, 5 Figures, submitted to PR

    Fetal alcohol exposure leads to abnormal olfactory bulb development and impaired odor discrimination in adult mice

    Get PDF
    Background: Children whose mothers consumed alcohol during pregnancy exhibit widespread brain abnormalities and a complex array of behavioral disturbances. Here, we used a mouse model of fetal alcohol exposure to investigate relationships between brain abnormalities and specific behavioral alterations during adulthood. Results: Mice drank a 10% ethanol so

    Metformin and high-sensitivity cardiac troponin I and T trajectories in type 2 diabetes patients: a post-hoc analysis of a randomized controlled trial

    Get PDF
    Background: Metformin has favorable effects on cardiovascular outcomes in both newly onset and advanced type 2 diabetes, as previously reported findings from the UK Prospective Diabetes Study and the HOME trial have demonstrated. Patients with type 2 diabetes present with chronically elevated circulating cardiac troponin levels, an established predictor of cardiovascular endpoints and prognostic marker of subclinical myocardial injury. It is unknown whether metformin affects cardiac troponin levels. The study aimed to evaluate cardiac troponin I and T trajectories in patients with diabetes treated either with metformin or placebo. Methods: This study is a post-hoc analysis of a randomized controlled trial (HOME trial) that included 390 patients with advanced type 2 diabetes randomized to 850 mg metformin or placebo up to three times daily concomitant to continued insulin treatment. Cardiac troponin I and T concentrations were measured at baseline and after 4, 17, 30, 43 and 52 months. We evaluated cardiac troponin trajectories by linear mixed-effects modeling, correcting for age, sex, smoking status and history of cardiovascular disease. Results: This study enrolled 390 subjects, of which 196 received metformin and 194 received placebo. In the treatment and placebo groups, mean age was 64 and 59 years; with 50% and 58% of subjects of the female sex, respectively. Despite the previously reported reduction of macrovascular disease risk in this cohort by metformin, linear mixed-effects regression modelling did not reveal evidence for an effect on cardiac troponin I and cardiac troponin T levels [− 8.4% (− 18.6, 3.2), p = 0.150, and − 4.6% (− 12, 3.2), p = 0.242, respectively]. A statistically significant time-treatment interaction was found for troponin T [− 1.6% (− 2.9, − 0.2), p = 0.021] but not troponin I concentrations [− 1.5% (− 4.2, 1.2), p = 0.263]. Conclusions: In this post-hoc analysis of a 4.3-year randomized controlled trial, metformin did not exert a clinically relevant effect on cardiac troponin I and cardiac troponin T levels when compared to placebo. Cardioprotective effects of the drug observed in clinical studies are not reflected by a reduction in these biomarkers of subclinical myocardial injury. Trial registration ClinicalTrials.gov identifier NCT00375388

    Long term treatment with metformin in patients with type 2 diabetes and risk of vitamin B-12 deficiency: randomised placebo controlled trial

    Get PDF
    Objectives To study the effects of metformin on the incidence of vitamin B-12 deficiency (<150 pmol/l), low concentrations of vitamin B-12 (150-220 pmol/l), and folate and homocysteine concentrations in patients with type 2 diabetes receiving treatment with insulin

    Influence of demagnetization in remanence curves of magnetic thin films

    Get PDF
    Remanent magnetization curves of perpendicular magnetic thin films are simulated and measured. The simulations are used to investigate the theoretical influence of the strong demagnetizing field present in these films. Conclusions are drawn from this on how remanence curves should be measured and how they should be corrected for the demagnetizing influence. The experimental part consists of measurements on Fe‐Alumite, Co‐Pt–based multilayers, and Co‐Cr. In addition the latter material is also artificially patterned into microstrips in order to investigate the influence of demagnetization on remanence curves experimentally

    The Shapes of Flux Domains in the Intermediate State of Type-I Superconductors

    Full text link
    In the intermediate state of a thin type-I superconductor magnetic flux penetrates in a disordered set of highly branched and fingered macroscopic domains. To understand these shapes, we study in detail a recently proposed "current-loop" (CL) model that models the intermediate state as a collection of tense current ribbons flowing along the superconducting-normal interfaces and subject to the constraint of global flux conservation. The validity of this model is tested through a detailed reanalysis of Landau's original conformal mapping treatment of the laminar state, in which the superconductor-normal interfaces are flared within the slab, and of a closely-related straight-lamina model. A simplified dynamical model is described that elucidates the nature of possible shape instabilities of flux stripes and stripe arrays, and numerical studies of the highly nonlinear regime of those instabilities demonstrate patterns like those seen experimentally. Of particular interest is the buckling instability commonly seen in the intermediate state. The free-boundary approach further allows for a calculation of the elastic properties of the laminar state, which closely resembles that of smectic liquid crystals. We suggest several new experiments to explore of flux domain shape instabilities, including an Eckhaus instability induced by changing the out-of-plane magnetic field, and an analog of the Helfrich-Hurault instability of smectics induced by an in-plane field.Comment: 23 pages, 22 bitmapped postscript figures, RevTex 3.0, submitted to Phys. Rev. B. Higher resolution figures may be obtained by contacting the author

    Breast cancer risk among first-generation migrants in the Netherlands

    Get PDF
    We investigated breast cancer incidence in migrants in the Netherlands in 1988-1998. The standardised incidence ratio for breast cancer in Northwest-Netherlands was statistically significantly reduced for women born in Surinam (0.56), Turkey (0.29) and Morocco (0.22). The proportion of women with advanced stages (III and IV) did not differ significantly between migrants and women born in the Netherlands

    Dosimetric characterization of a microDiamond detector in clinical scanned carbon ion beams

    Get PDF
    Purpose: To investigate for the first time the dosimetric properties of a new commercial synthetic diamond detector (PTW microDiamond) in high-energy scanned clinical carbon ion beams generated by a synchrotron at the CNAO facility. Methods: The detector response was evaluated in a water phantom with actively scanned carbon ion beams ranging from 115 to 380 MeV/u (30-250 mm Bragg peak depth in water). Homogeneous square fields of 3×3 and 6×6 cm2 were used. Short- and medium-term (2 months) detector response stability, dependence on beam energy as well as ion type (carbon ions and protons), linearity with dose, and directional and dose-rate dependence were investigated. The depth dose curve of a 280 MeV/u carbon ion beam, scanned over a 3×3 cm<sup>2</sup> area, was measured with the microDiamond detector and compared to that measured using a PTW Advanced Markus ionization chamber, and also simulated using FLUKA Monte Carlo code. The detector response in two spread-out-Bragg-peaks (SOBPs), respectively, centered at 9 and 21 cm depths in water and calculated using the treatment planning system (TPS) used at CNAO, was measured. Results: A negligible drift of detector sensitivity within the experimental session was seen, indicating that no detector preirradiation was needed. Short-term response reproducibility around 1% (1 standard deviation) was found. Only 2% maximum variation of microDiamond sensitivity was observed among all the evaluated proton and carbon ion beam energies. The detector response showed a good linear behavior. Detector sensitivity was found to be dose-rate independent, with a variation below 1.3% in the evaluated dose-rate range. A very good agreement between measured and simulated Bragg curves with both microDiamond and Advanced Markus chamber was found, showing a negligible LET dependence of the tested detector. A depth dose curve was also measured by positioning the microDiamond with its main axis oriented orthogonally to the beam direction. A strong distortion in Bragg peak measurement was observed, confirming manufacturer recommendation on avoiding such configuration. Very good results were obtained for SOBP measurements, with a difference below 1% between measured and TPS-calculated doses. The stability of detector sensitivity in the observation period was within the experimental uncertainty. Conclusions: Dosimetric characterization of a PTW microDiamond detector in high-energy scanned carbon ion beams was performed. The results of the present study showed that this detector is suitable for dosimetry of clinical carbon ion beams, with a negligible LET and dose-rate dependence
    corecore