3,579 research outputs found

    Fully automated segmentation and tracking of the intima media thickness in ultrasound video sequences of the common carotid artery

    Get PDF
    Abstract—The robust identification and measurement of the intima media thickness (IMT) has a high clinical relevance because it represents one of the most precise predictors used in the assessment of potential future cardiovascular events. To facilitate the analysis of arterial wall thickening in serial clinical investigations, in this paper we have developed a novel fully automatic algorithm for the segmentation, measurement, and tracking of the intima media complex (IMC) in B-mode ultrasound video sequences. The proposed algorithm entails a two-stage image analysis process that initially addresses the segmentation of the IMC in the first frame of the ultrasound video sequence using a model-based approach; in the second step, a novel customized tracking procedure is applied to robustly detect the IMC in the subsequent frames. For the video tracking procedure, we introduce a spatially coherent algorithm called adaptive normalized correlation that prevents the tracking process from converging to wrong arterial interfaces. This represents the main contribution of this paper and was developed to deal with inconsistencies in the appearance of the IMC over the cardiac cycle. The quantitative evaluation has been carried out on 40 ultrasound video sequences of the common carotid artery (CCA) by comparing the results returned by the developed algorithm with respect to ground truth data that has been manually annotated by clinical experts. The measured IMTmean ± standard deviation recorded by the proposed algorithm is 0.60 mm ± 0.10, with a mean coefficient of variation (CV) of 2.05%, whereas the corresponding result obtained for the manually annotated ground truth data is 0.60 mm ± 0.11 with a mean CV equal to 5.60%. The numerical results reported in this paper indicate that the proposed algorithm is able to correctly segment and track the IMC in ultrasound CCA video sequences, and we were encouraged by the stability of our technique when applied to data captured under different imaging conditions. Future clinical studies will focus on the evaluation of patients that are affected by advanced cardiovascular conditions such as focal thickening and arterial plaques

    ‘Qu’il est loin mon pays’: staging (be)longing in Massenet’s Sapho

    Get PDF
    At first glance, Jules Massenet's opera Sapho (1897) might appear to water down its source material, substituting the searing social commentary of Alphonse Daudet's novel (1884) with idealised tropes of the Midi. This article, however, seeks to complicate this reading, arguing that Sapho moves beyond the regionalism of its operatic predecessors, while entirely reimagining Daudet's novel for a new medium. It highlights how the themes of nostalgia and belonging are established in Henri Cain and Arthur Bernède's libretto, reiterated by Léon Carvalho's staging, and intensified in Massenet's score, thereby nuancing and enriching our understanding of adaptation for the operatic stage

    Nomogram for the Evaluation of Blackbody Radiancy and of Peak and Total Intensities for Spectral Lines with Doppler Contour

    Get PDF
    A nomogram has been constructed for the determination of blackbody radiancy and of peak and total intensities for spectral lines with Doppler contour. The basic equations used for the construction of the nomogram and the use of the nomogram are described briefly. A method is outlined for determining absolute values of total intensities for spectral lines with combined Doppler and resonance contour by using the nomogram in conjunction with the “curves of growth.

    Evaluation of novel depressed collector for linear-beam microwave tubes

    Get PDF
    Evaluation tests to demonstrate feasibility of increasing efficiency of linear beam microwave tubes using novel depressed collecto

    Phase linearity of the 914H coupled-cavity traveling wave tube

    Get PDF
    Tests of phase deviation from linearity were made on two 914H coupled-cavity traveling wave tubes (TWT). One tube had a voltage standing wave ratio (VSWR) of 2.4 and the other 1.4. The data showed that phase deviation is primarily a function of the amplitude and shape of the output VSWR. It was predicted that the low-VSWR tube would give a better system performance than the tube with a high VSWR. This prediction was confirmed by the Advanced Communications Technology Satellite (ACTS) system tests performed at the NASA Lewis Research Center. A possible improvement in the construction and stability of coupled-cavity TWT's is discussed

    Combined EISCAT radar and optical multispectral and tomographic observations of black aurora

    Get PDF
    Black auroras are recognized as spatially well-defined regions within a uniform diffuse auroral background where the optical emission is significantly reduced. Black auroras typically appear post-magnetic midnight and during the substorm recovery phase, but not exclusively so. We report on the first combined multimonochromatic optical imaging, bistatic white-light TV recordings and incoherent scatter radar observations of black aurora by EISCAT of the phenomenon. From the relatively larger reduction in luminosity at 4278 Å than at 8446 Å we show that nonsheared black auroras are most probably not caused by downward directed electrical fields at low altitude. From the observations, we determine this by relating the height and intensity of the black aurora to precipitating particle energy within the surrounding background diffuse aurora. The observations are more consistent with an energy selective loss cone. Hence the mechanism causing black aurora is most probably active in the magnetosphere rather than close to Earth
    corecore