38 research outputs found

    The effect of intermolecular interaction on excited states in p − DTS(FBTTH 2

    Get PDF
    Using optical spectroscopy in solution and thin film, and supported by quantum chemical calculations, we investigated the aggregation process of the donor-acceptor type molecule p − DTS(FBTTH2)2. We demonstrate that cooling a solution induces a disorder-order phase transition that proceeds in three stages analogous to the steps observed in semi-rigid conjugated polymers. By analyzing the spectra, we are able to identify the spectral signature of monomer and aggregate in absorption and emission. From this we find that in films, the fraction of aggregates is near 100% which is in contrast to films made from semi-rigid conjugated polymers

    Diagnostic Accuracy of Fine Needle Biopsy for Metastatic Melanoma and Its Implications for Patient Management

    Get PDF
    The use of fine needle biopsy (FNB) for the diagnosis of metastatic melanoma can lead to the early removal and treatment of metastases, reduce the frequency of unnecessary surgery, and facilitate the staging of patients enrolled in clinical trials of adjuvant therapies. In this study, the accuracy of FNB for the diagnosis of metastatic melanoma was investigated. A retrospective cohort study was performed with 2204 consecutive FNBs performed on 1416 patients known or suspected to have metastatic melanoma. Almost three-quarters (1582) of these FNBs were verified by either histopathologic diagnosis following surgical resection or clinical follow-up. FNB for metastatic melanoma was found to have an overall sensitivity of 92.1% and a specificity of 99.2%, with 69 false-negative and 5 false-positive findings identified. The sensitivity of the procedure was found to be influenced by six factors. The use of immunostains, reporting of the specimen by a cytopathologist who had reported >500 cases, lesions located in the skin and subcutis, and patients with ulcerated primary melanomas were factors associated with a significant improvement in the sensitivity of the test. However, FNBs performed in masses located in lymph nodes of the axilla and FNBs that required more than one needle pass to obtain a sample were far more likely to result in false-negative results. FNB is a rapid, accurate, and clinically useful technique for the assessment of disease status in patients with suspected metastatic melanoma

    Glucose transporter-1 deficiency syndrome: the expanding clinical and genetic spectrum of a treatable disorder

    Get PDF
    Glucose transporter-1 deficiency syndrome is caused by mutations in the SLC2A1 gene in the majority of patients and results in impaired glucose transport into the brain. From 2004-2008, 132 requests for mutational analysis of the SLC2A1 gene were studied by automated Sanger sequencing and multiplex ligation-dependent probe amplification. Mutations in the SLC2A1 gene were detected in 54 patients (41%) and subsequently in three clinically affected family members. In these 57 patients we identified 49 different mutations, including six multiple exon deletions, six known mutations and 37 novel mutations (13 missense, five nonsense, 13 frame shift, four splice site and two translation initiation mutations). Clinical data were retrospectively collected from referring physicians by means of a questionnaire. Three different phenotypes were recognized: (i) the classical phenotype (84%), subdivided into early-onset (<2 years) (65%) and late-onset (18%); (ii) a non-classical phenotype, with mental retardation and movement disorder, without epilepsy (15%); and (iii) one adult case of glucose transporter-1 deficiency syndrome with minimal symptoms. Recognizing glucose transporter-1 deficiency syndrome is important, since a ketogenic diet was effective in most of the patients with epilepsy (86%) and also reduced movement disorders in 48% of the patients with a classical phenotype and 71% of the patients with a non-classical phenotype. The average delay in diagnosing classical glucose transporter-1 deficiency syndrome was 6.6 years (range 1 month-16 years). Cerebrospinal fluid glucose was below 2.5 mmol/l (range 0.9-2.4 mmol/l) in all patients and cerebrospinal fluid : blood glucose ratio was below 0.50 in all but one patient (range 0.19-0.52). Cerebrospinal fluid lactate was low to normal in all patients. Our relatively large series of 57 patients with glucose transporter-1 deficiency syndrome allowed us to identify correlations between genotype, phenotype and biochemical data. Type of mutation was related to the severity of mental retardation and the presence of complex movement disorders. Cerebrospinal fluid : blood glucose ratio was related to type of mutation and phenotype. In conclusion, a substantial number of the patients with glucose transporter-1 deficiency syndrome do not have epilepsy. Our study demonstrates that a lumbar puncture provides the diagnostic clue to glucose transporter-1 deficiency syndrome and can thereby dramatically reduce diagnostic delay to allow early start of the ketogenic die

    The immunology and genetics of resistance of sheep to Teladorsagia circumcincta

    Get PDF

    Search for eccentric black hole coalescences during the third observing run of LIGO and Virgo

    Get PDF
    Despite the growing number of confident binary black hole coalescences observed through gravitational waves so far, the astrophysical origin of these binaries remains uncertain. Orbital eccentricity is one of the clearest tracers of binary formation channels. Identifying binary eccentricity, however, remains challenging due to the limited availability of gravitational waveforms that include effects of eccentricity. Here, we present observational results for a waveform-independent search sensitive to eccentric black hole coalescences, covering the third observing run (O3) of the LIGO and Virgo detectors. We identified no new high-significance candidates beyond those that were already identified with searches focusing on quasi-circular binaries. We determine the sensitivity of our search to high-mass (total mass M&gt;70 M⊙) binaries covering eccentricities up to 0.3 at 15 Hz orbital frequency, and use this to compare model predictions to search results. Assuming all detections are indeed quasi-circular, for our fiducial population model, we place an upper limit for the merger rate density of high-mass binaries with eccentricities 0&lt;e≤0.3 at 0.33 Gpc−3 yr−1 at 90\% confidence level

    Ultralight vector dark matter search using data from the KAGRA O3GK run

    Get PDF
    Among the various candidates for dark matter (DM), ultralight vector DM can be probed by laser interferometric gravitational wave detectors through the measurement of oscillating length changes in the arm cavities. In this context, KAGRA has a unique feature due to differing compositions of its mirrors, enhancing the signal of vector DM in the length change in the auxiliary channels. Here we present the result of a search for U(1)B−L gauge boson DM using the KAGRA data from auxiliary length channels during the first joint observation run together with GEO600. By applying our search pipeline, which takes into account the stochastic nature of ultralight DM, upper bounds on the coupling strength between the U(1)B−L gauge boson and ordinary matter are obtained for a range of DM masses. While our constraints are less stringent than those derived from previous experiments, this study demonstrates the applicability of our method to the lower-mass vector DM search, which is made difficult in this measurement by the short observation time compared to the auto-correlation time scale of DM

    Public Utility Pricing and Capacity Choice Under Risk: A Rational Expectations Approach

    Full text link

    Feasibility studies for a high energy physics MC program on massive parallel platforms

    No full text
    The parallelization of a Monte Carlo program for the NA48 experiment is presented. As a first step, a task farming structure was realized. Based on this, a further step, making use of a distributed database for showers in the electro-magnetic calorimeter, was implemented. Further possibilities for using parallel processing for a quasi-real time calibration of the calorimeter are described
    corecore