73 research outputs found

    The Efficient Computational Tools For The Design Process Of The Transcritical Two-Phase Ejectors For Natural-Based Working Fluids

    Get PDF
    Naturalbased working fluids for refrigeration are becoming a standard commercial solution due to the dynamic research and development in this area as well as law regulations. The stateoftheart ejector technology for R744 systems reached current status due to a significant interest on modelling approaches and effective regulation concepts. The development path of the fast and efficient design tools based on the numerical simulations could be described as a key feature for the R744 commercial technology. In this study, one of the most effective numerical approaches dedicated for the twophase CO2 ejector design and analysis is discussed. Namely, homogeneous equilibrium and relaxation model for high motive pressures and mixture approach for lower motive pressures were reviewed. According to the requirements of the effective design tools, the comparison also included a prediction of the vapour quality at given operating conditions and the corresponding computational costs. Moreover, several research studies on swirling and bypassing solutions as well as commercial applications of multiejector device and reduced order models for regulation systems where aforementioned models were used was described. Conclusions on a potential of the reviewed approaches were formulated having regard possible utilisation for the design process of the ejector based R744 systems

    Experimental Test Rig For The Visualisation Study Of The Transcritical Flow In The Two-Phase R744 Ejectors

    Get PDF
    Recent studies have provided the significant number of approaches to enhance the performance of a twophase ejector, especially for transcritical CO2 cycles. However, the investigation of the mixing process is still challenging matter due to the highspeed fluid flow coupled with mixing of vapour and partially evaporated liquid stream. On the other hand, these phenomena directly influence the ejector efficiency. The behaviour of the aforementioned processes would be valuable for validation the numerical models as well as a required control of the system operation. Hence, in this work, the laboratory test rig for visualisation of the CO2 ejector mixing processes along suction nozzle, premixing chamber and diffuser was developed and manufactured. The visualisation techniques used for this study include the highspeed camera recordings and PIV measurements. The work consists of installation description, including the measurement approaches, solution predicted by the computational model for the transparent construction of the ejector and visualisation procedures. The selected onand offdesign operating points were described having regard ejector performance factors and its correlation with the output of the visualisation procedure

    Lagrangian Reachtubes: The Next Generation

    Full text link
    We introduce LRT-NG, a set of techniques and an associated toolset that computes a reachtube (an over-approximation of the set of reachable states over a given time horizon) of a nonlinear dynamical system. LRT-NG significantly advances the state-of-the-art Langrangian Reachability and its associated tool LRT. From a theoretical perspective, LRT-NG is superior to LRT in three ways. First, it uses for the first time an analytically computed metric for the propagated ball which is proven to minimize the ball's volume. We emphasize that the metric computation is the centerpiece of all bloating-based techniques. Secondly, it computes the next reachset as the intersection of two balls: one based on the Cartesian metric and the other on the new metric. While the two metrics were previously considered opposing approaches, their joint use considerably tightens the reachtubes. Thirdly, it avoids the "wrapping effect" associated with the validated integration of the center of the reachset, by optimally absorbing the interval approximation in the radius of the next ball. From a tool-development perspective, LRT-NG is superior to LRT in two ways. First, it is a standalone tool that no longer relies on CAPD. This required the implementation of the Lohner method and a Runge-Kutta time-propagation method. Secondly, it has an improved interface, allowing the input model and initial conditions to be provided as external input files. Our experiments on a comprehensive set of benchmarks, including two Neural ODEs, demonstrates LRT-NG's superior performance compared to LRT, CAPD, and Flow*.Comment: 12 pages, 14 figure

    Heat Transfer Process Within The R744 Two-phase Ejector: Numerical And Experimental Study

    Get PDF
    The proposed three dimensional CFD model to simulate the influence of the heat transfer on the R744 two-phase ejector performance is presented. The numerical model was developed based on the homogeneous real fluid flow assumption with the enthalpy-based formulation of the energy equation. The R744 two-phase ejector was designed to evaluate the temperature profile within the ejector walls. The prototype R744 ejector for experimental investigation was manufactured by Institute of Thermal Technology and ATM in Poland. The performance measurements were carried out at a R744 test facility at SINTEF/NTNU in Norway. The foregoing ejector was equipped with the thirteen thermocouples located inside the ejector to measure the wall temperature in different ejector section i.e. the motive nozzle, the suction nozzle, the mixing section and the diffuser. The experimental test campaign at different operating conditions typical for refrigeration application was carried out and the uncertainty of the measurement was defined. Moreover, the experimental data are applied to validate the CFD results at defined operating conditions. The numerical results were set to evaluate the influence of the wall temperature on the two-phase flow parameters. In addition, the heat transfer coefficient of the two-phase flow within the ejector was estimated. The analysis of the heat transfer process within the R744 two-phase ejector let to investigate the influence of the ambient conditions and the different temperature levels of the motive and suction streams on the ejector performance

    Thermal analysis of 8.5 MVA disk-type power transformer cooled by biodegradable ester oil working in ONAN mode by using advanced EMAG–CFD–CFD coupling

    Get PDF
    Power transformers are the first devices used to transfer the electrical energy produced in power plants to the grid to supply the industrial and individual receivers with electricity. The heat generation in windings and core, being an effect of the power losses, is usually dissipated in large units by using mineral oils, which are harmful to the environment. Nowadays, the industry and global society seek environmentally-friendly alternatives. One of the most promising substitute for their high biodegradability, safety in operation, and favourable thermo-physical properties are natural ester oils. For this reason, a numerical study of 8.5 MVA disk-type power transformer cooled using conventional mineral oil and a commercially used rapeseed ester oil is presented in this paper. Moreover, due to different thermal behaviour of the considered oils, the comparison was made for the unit working in different seasons of hot and moderate climate zones (Argentina and Poland). In the numerical approach, electromagnetic (EMAG) and computational fluid dynamics (CFD) models were used for a detailed study of the selected device. In particular, a novel and very efficient EMAG–CFD–CFD coupling procedure was developed to assess the cooling of the large power transformer. Such a coupled computational procedure allowed for the detailed investigation of the power loss, oil flow characteristics, and temperatures with a satisfying computational effort. The results showed that the average windings temperatures are higher by 2–9 K when the ester oil is used, dependent on the ambient conditions. The hotspot temperature in the low voltage windings increased by up to 9 K and up to 18 K in the high voltage windings using ester oil. According to the results, the oil duct construction requires modification in the high voltage region for transformers cooled using mineral oil in cold climate conditions.Fil: Stebel, Michal. Silesian University Of Technology; PoloniaFil: Kubiczek, Krzysztof. Silesian University Of Technology; PoloniaFil: Rios Rodriguez, Gustavo Adolfo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Centro de Investigaciones en Métodos Computacionales. Universidad Nacional del Litoral. Centro de Investigaciones en Métodos Computacionales; ArgentinaFil: Palacz, Michal. Silesian University Of Technology; PoloniaFil: Garelli, Luciano. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Centro de Investigaciones en Métodos Computacionales. Universidad Nacional del Litoral. Centro de Investigaciones en Métodos Computacionales; ArgentinaFil: Melka, Bartlomiej. Silesian University Of Technology; PoloniaFil: Haida, Michal. Silesian University Of Technology; PoloniaFil: Bodys, Jakub. Silesian University Of Technology; PoloniaFil: Nowak, Andrzej J.. Silesian University Of Technology; PoloniaFil: Lasek, Pawel. Silesian University Of Technology; PoloniaFil: Stepien, Mariusz. Silesian University Of Technology; PoloniaFil: Pessolani, Francisco. Tadeo Czerweny S.a.; ArgentinaFil: Amadei, Mauro. Tadeo Czerweny S.a.; ArgentinaFil: Granata, Daniel. Tadeo Czerweny S.a.; ArgentinaFil: Storti, Mario Alberto. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Centro de Investigaciones en Métodos Computacionales. Universidad Nacional del Litoral. Centro de Investigaciones en Métodos Computacionales; ArgentinaFil: Smolka, Jacek. Silesian University Of Technology; Poloni

    Development of the natural working fluid‐based refrigeration system for domestic scale freeze‐dryer

    Get PDF
    In this work, the analysis of the refrigeration system designed for the FrostX 10 freeze‐dryer is presented. The main goal of this study was to experimentally investigate the reference R452a freeze‐dryer and prepare recommendations for a machine based on the R290 refrigeration unit. In order to guarantee the temperature requirements and efficient operation of that unit, the analysis of suitable natural refrigerants was performed. Consequently, propane (R290) was selected. In addition, a number of modifications were introduced for the prototype system. System analysis showed that the replacement of the refrigerant in the existing system improves the system energy efficiency by approximately 18%. During the experimental campaign of the basic refrigeration unit, an unstable operation of the evaporator was found. The concept of a new cooling system for a prototype device was presented. The configuration and type of heat exchanger to maximise the performance of the ice trap of the freeze‐dryer were proposed.Development of the natural working fluid‐based refrigeration system for domestic scale freeze‐dryeracceptedVersio

    Przezcewnikowa implantacja zastawki aortalnej w leczeniu dysfunkcyjnych bioprotez chirurgicznych i przezcewnikowych. Opinia ekspertów Asocjacji Interwencji Sercowo-Naczyniowych Polskiego Towarzystwa Kardiologicznego

    Get PDF
    Ponad 15-letnie doświadczenie i wyniki dużych badań obserwacyjnych, na podstawie których tworzone są wytyczne, wskazują na bezpieczeństwo i skuteczność zabiegów przezcewnikowej implantacji „zastawki w zastawkę” (ViV-TAVI, valve-in-valve transcatheter aortic valve implantation), zmniejszając tym samym potrzebę reoperacji u pacjentów wysokiego ryzyka. Oczekuje się, że liczba zabiegów ViV-TAVI w Polsce, szacowana na około 2% wszystkich przezcewnikowej implantacji zastawki aortalnej w 2020 roku, będzie rosła. Niniejszy dokument ma na celu przegląd aspektów proceduralnych ViV-TAVI, w tym odpowiednich metod planowania przedzabiegowego, sposobów optymalizacji wyników hemodynamicznych i ograniczania ryzyka okluzji tętnic wieńcowych. Dokument zawiera również wstępny przegląd wskazań i wytycznych dotyczących ponownego zabiegu TAVI (re-do TAVI) u pacjentów ze zdegenerowanymi zastawkami przezcewnikowymi
    corecore