13,306 research outputs found
Method of plating copper on aluminum Patent
Method of plating copper on aluminum to permit conventional soldering of structural aluminum bodie
GRAPE - A Balloon-Borne Gamma-Ray Polarimeter Experiment
This paper reviews the development status of GRAPE (the Gamma-Ray Polarimeter
Experiment), a hard X-ray Compton Polarimeter. The purpose of GRAPE is to
measure the polarization of hard X-rays in the 50-300 keV energy range. We are
particularly interested in X-rays that are emitted from solar flares and
gamma-ray bursts (GRBs), although GRAPE could also be employed in the study of
other astrophysical sources. Accurately measuring the polarization of the
emitted radiation will lead to a better understating of both emission
mechanisms and source geometries. The GRAPE design consists of an array of
plastic scintillators surrounding a central high-Z crystal scintillator. The
azimuthal distribution of photon scatters from the plastic array into the
central calorimeter provides a measure of the polarization fraction and
polarization angle of the incident radiation. The design of the detector
provides sensitivity over a large field-of-view (>pi steradian). The design
facilitates the fabrication of large area arrays with minimal deadspace. This
paper presents the latest design concept and the most recent results from
laboratory tests of a GRAPE science model.Comment: 6 pages; paper presented at the FRASCATI Workshop 2005 on
Multifrequency Behaviour of High Energy Cosmic Sources; submitted to Chinese
Journal of Astronomy and Astrophysic
Radio sources near the core of globular cluster 47 Tucanae
We present ATCA radio images of the globular cluster 47 Tucanae made at 1.4
and 1.7 GHz and provide an analysis of the radio sources detected within 5
arcmin of the cluster centre. 11 sources are detected, most of which are
clustered about the core of 47 Tuc. Both of the pulsars in 47 Tuc whose
positions are known can be identified with sources in the 1.4 GHz image. The
source distribution has a characteristic radius of ~100 arcsec, larger than the
23 arcsec radius of the cluster core. We compare source positions with the
positions of nine X-ray sources and find no correspondence.Comment: 6 pages, 4 postscript figures, LaTeX with MNRAS macro; Accepted by
MNRA
Inertial measurement unit pre-processors and post-flight STS-1 comparisons
The flight results show that the relative tri-redundant Inertial Measurement Unit IMU performance throughout the entire entry flight was within the expected accuracy. Comparisons are presented which show differences in the accumulated sensed velocity changes as measured by the tri-redundant IMUs (in Mean Equator and Equinox of 1950.0), differences in the equivalent inertial Euler angles as measured with respect to the M50 system, and finally, preliminary instrument calibrations determined relative to the ensemble average measurement set. Also, differences in the derived body axes rates and accelerations are presented. Because of the excellent performance of the IMUs during the STS-1 entry, the selection as to which particular IMU would best serve as the dynamic data source for entry reconstruction is arbitrary
Fast wavelength-tunable ultra-violet laser source for confocal Fura-2AM imaging
We report a novel wavelength-flexible laser source for three-dimensional ultra-violet imaging. Based on supercontinuum generation in photonic crystal fiber, the resultant broadband laser source extended from A = 331 nm into the visible region of the spectrum. Using an electronically-controlled filter wheel and filter set with a response time of approximately 50 ins, rapid wavelength selection was performed. The described scheme is capable of exciting the current range of ultra-violet-excited fluorophores and the simple and rapid wavelength control also provides a new approach for fast ratiometric imaging of Fura-2AM, facilitating an easy method of performing quantitative intracellular calcium concentration measurements
Time-scales of Radio Emission in PSR J0437-4715 at 327 MHz
Time-scales of radio emission are studied in PSR J0437-4715 at 327 MHz using
almost half a million periods of high quality data from Ooty Radio Telescope.
The radio emission in this milli second pulsar occurs on a short (s) time-scale
of approximately 0.026 +- 0.001 periods, and on a (l) time-scale that is much
longer than the widths of the components of the integrated profile
(approximately 0.05 periods). The width of the s emission increases with its
increasing relative contribution to the total radio emission. This may provide
constraints for the details of discharge of vacuum gaps above pulsar polar
caps. The s emission occasionally takes place in the form of intense spikes,
which are confined to the main component of the integrated profile for 90 per
cent of the time. The positions of spikes within a component of the integrated
profile have no simple relation to the shape of that component. This may have
impact on the interpretation of the integrated profile components in terms of
independent regions of emission on the polar cap.Comment: Accepted for publication in Vol 543 (1 Nov 2000) of The Astrophysical
Journa
Characterisation of periodically poled materials using nonlinear microscopy
Periodically poled crystalline materials are extremely attractive for processes such as second harmonic generation and optical parametric generation due to their very high conversion efficiency. For optimal performance, fabrication of poled regions with sub-micron tolerance is required. In this paper we introduce multi-photon laser scanning luminescence microscopy as a powerful minimally-invasive measurement technique which provides information about internal device structure with high spatial resolution that cannot be easily obtained with existing methods. A comparative study of confocal and multi-photon imaging of periodically poled crystalline materials is also performed
- …