31 research outputs found

    Fast and Fully Automatic 3-D Echocardiographic Segmentation Using B-Spline Explicit Active Surfaces: Feasibility Study and Validation in a Clinical Setting

    No full text
    A novel framework to efficiently deal with three-dimensional (3-D) segmentation of challenging inhomogeneous data in real-time has been recently introduced by the authors. However, the existing framework still relied on manual initialization, which prevented taking full advantage of the computational speed of the method. In the present article, an automatic initialization scheme adapted to 3-D, echocardiographic data is proposed. Moreover, a novel segmentation functional, which explicitly takes the darker appearance of the blood into account, is also introduced. The resulting automatic segmentation framework provides an efficient, fast and accurate solution for quantification of the main left ventricular volumetric indices used in clinical routine. In practice, the observed computation times are in the order of 1 s.status: publishe

    In-vivo validation of a new clinical tool to quantify three-dimensional myocardial strain using ultrasound

    Get PDF
    Three-dimensional (3D) strain analysis based on real-time 3-D echocardiography (RT3DE) has emerged as a novel technique to quantify regional myocardial function. The goal of this study was to evaluate accuracy of a novel model-based 3D tracking tool (eSie Volume Mechanics, Siemens Ultrasound, Mountain View, CA, USA) using sonomicrometry as an independent measure of cardiac deformation. Thirteen sheep were instrumented with microcrystals sutured to the epi- and endocardium of the inferolateral left ventricular wall to trace myocardial deformation along its three directional axes of motion. Paired acquisitions of RT3DE and sonomicrometry were made at baseline, during inotropic modulation and during myocardial ischemia. Accuracy of 3D strain measurements was quantified and expressed as level of agreement with sonomicrometry using linear regression and Bland-Altman analysis. Correlations between 3D strain analysis and sonomicrometry were good for longitudinal and circumferential strain components (r = 0.78 and r = 0.71) but poor for radial strain (r = 0.30). Accordingly, agreement (bias ± 2SD) was -5 ± 6 % for longitudinal, -5 ± 7 % for circumferential, and 15 ± 19 % for radial strain. Intra-observer variability was low for all components (intra-class correlation coefficients (ICC) of respectively 0.89, 0.88 and 0.95) while inter-observer variability was higher, in particular for radial strain (ICC = 0.41). The present study shows that 3D strain analysis provided good estimates of circumferential and longitudinal strain, while estimates of radial strain were less accurate between observers.status: publishe
    corecore