77 research outputs found

    Detection of hepatic portal venous gas: its clinical impact and outcome

    Get PDF
    The clinical impact and outcome of a rare radiographic finding of hepatic portal venous gas (HPVG) as well as the effectiveness of computed tomography (CT), CT scanogram, and conventional radiography in the detection of HPVG were retrospectively analyzed. CT scans, CT scanogram, and plain film radiographs of 11 patients with HPVG were reviewed and compared with their medical records and surgical and pathology reports. Eight of the 11 patients underwent plain film radiographs 1day before or after the CT scan. HPVG was detected at CT in all 11 patients, on CT scanogram in three (3 of 11, 27.3%), and on plain films in one (one of eight, 12.5%). In nine of 11 patients (81.8%), CT revealed an associated pneumatosis intestinalis. In six of the 11 patients (54.6%), acute mesenteric ischemia was the underlying disease for HPVG. Seven patients (63.6%) underwent emergency exploratory laparotomy. The mortality rate for HPVG alone was 27.3% (3 of 11) and for HPVG related to mesenteric bowel disease 50% (three of six). Acute mesenteric ischemia is the most common cause of HPVG, which continues to have a predictably higher mortality. CT is superior to CT scanograms and radiographs in the detection of HPVG and its underlying diseases and, therefore, should be used as the primary diagnostic too

    A novel multiple-trauma CT-scanning protocol using patient repositioning

    Get PDF
    Emergency CT examination is considered to be a trade-off between a short scan time and the acceptance of artifacts. This study evaluates the influence of patient repositioning on artifacts and scan time. Eighty-three consecutive multiple-trauma patients were included in this prospective study. Patients were examined without repositioning (group 1, n=39) or with patient rotation to feet-first with arms raised for scanning the chest and abdomen/pelvis (group 2, n=44). The mean scan time was 21min in group 1 and 25min in group 2 (P=0.01). The mean repositioning time in group 2 was 8min. Significantly, more artifacts were observed in group 1 (with a repeated scan in 7%) than in group 2 (P=0.0001). This novel multiple- trauma CT-scanning protocol with patient repositioning achieves a higher image quality with significantly fewer artifacts than without repositioning but increases scan time slightl

    Importance of extracolonic findings at IV contrast medium-enhanced CT colonography versus those at non-enhanced CT colonography

    Get PDF
    To compare the clinical importance of extracolonic findings at intravenous (IV) contrast-enhanced CT colonography versus those at non-enhanced CT colonography. IV contrast medium-enhanced (n=72) and non-enhanced (n=30) multidetector CT colonography was performed in 102 symptomatic patients followed by conventional colonoscopy on the same day. The impact of extracolonic findings on further work up and treatment was assessed by a review of patient records. Extracolonic findings were divided into two groups: either leading to further work up respectively having an impact on therapy or not. A total of 303 extracolonic findings were detected. Of those, 71% (215/303) were found on IV contrast-enhanced CT, and 29% (88/303) were found on non-enhanced CT colonography. The extracolonic findings in 25% (26/102) of all patients led to further work up or had an impact on therapy. Twenty-two of these patients underwent CT colonography with IV contrast enhancement, and four without. The percentage of extracolonic findings leading to further work up or having an impact on therapy was higher for IV contrast-enhanced (31%; 22/72) than for non-enhanced (13%; 4/30) CT scans (P=0.12). IV contrast-enhanced CT colonography produced more extracolonic findings than non-enhanced CT colonography. A substantially greater proportion of findings on IV contrast-enhanced CT colonography led to further work up and treatment than did non-enhanced CT colonograph

    Computed tomographic coronary angiography in patients with surgically treated type A aortic dissection: preliminary results

    Get PDF
    Acute type A aortic dissection is a serious emergency with a mortality rate of up to 40% within the first 24h when left untreated. Surgical therapy needs to be initiated promptly. Due to this urgent situation, preoperative evaluation of the coronary arteries is not routinely performed in these patients. The aim of this study was to evaluate the accuracy of 64-slice computed tomography angiography (CTA) for postoperative coronary artery assessment in these patients. Ten consecutive patients with two or more cardiovascular risk factors were prospectively enrolled. Patients had type A aortic dissection treated surgically with a supracoronary graft of the ascending aorta. Performance of CTA to exclude significant stenosis (>50% lumen narrowing) and/or coronary artery dissection was compared with quantitative coronary angiography. A total of 147 segments were evaluated. Three segments (2%) were excluded from analysis. CTA correctly assessed one of three significant stenoses in three patients and correctly excluded coronary artery disease (CAD) in six of ten patients. One patient was rated false positive. Overall accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of CT for identifying coronary artery disease by segment was 98%, 33%, 99%, 50%, and 99%, respectively (P < 0.05). By patient, it was 70%, 33%, 86%, 50%, and 75%, respectively. No coronary artery dissection was found. Noninvasive CTA may be a viable alternative to conventional angiography for postoperative coronary artery evaluation in patients with surgically treated type A aortic dissection and cardiovascular risk factors. An NPV of 99% should allow for reliable exclusion of CAD. Further studies with higher patient numbers are warrante

    Retrospective analysis of patients for development of nephrogenic systemic fibrosis following conventional angiography using gadolinium-based contrast agents

    Get PDF
    Purpose: The purpose was to retrospectively review the data of 27 patients with renal insufficiency who underwent conventional angiography with gadolinium-based contrast agents (GDBCA) as alternative contrast agents and assess the occurrence of nephrogenic systemic fibrosis (NSF) together with associated potential risk factors. Methods: This HIPAA-compliant study had institutional review board approval, and informed consent was waived. Statistical analysis was performed for all available laboratory and clinical data, including dermatology reports. Type and amount of the GDBCA used were recorded for angiography and additional MRI studies, if applicable. Serum creatinine levels (SCr) pre- and post-angiography were recorded, and estimated glomerular filtration rates (eGFR) were calculated. Results: Ten female and 17 male patients who underwent angiography with GDBCA were included. The mean amount of GDBCA administered was 44 ± 15.5ml (range 15-60ml) or 0.24 + 0.12mmol/kg (range 0.1-0.53mmol/kg). At the time of angiography all patients had renal insufficiency (eGFR <60ml/min/1.73m2). Mean eGFR pre-angiography was 26ml/min/1.73m2 and 33ml/min/1.73m2 post-angiography. The mean follow-up period covers 28months, range 1-84months. Additional MRI studies with GDBCA administration were performed in 15 patients. One patient with typical skin lesions had developed biopsy-confirmed NSF. Conclusion: Conventional arterial angiography with GDBCA may play a role in the development of NSF in patients with renal insufficiency. Alternative contrast agents, such as CO2 angiography or rather the use of low doses of iodinated contrast agents, should be considered in these patient

    Whole-body computed tomography for multiple traumas using a triphasic injection protocol

    Get PDF
    To evaluate a triphasic injection protocol for whole-body multidetector computed tomography (MDCT) in patients with multiple trauma. Fifty consecutive patients (41 men) were examined. Contrast medium (300mg/mL iodine) was injected starting with 70mL at 3mL/s, followed by 0.1mL/s for 8s, and by another bolus of 75mL at 4mL/s. CT data acquisition started 50s after the beginning of the first injection. Two experienced, blinded readers independently measured the density in all major arteries, veins, and parenchymatous organs. Image quality was assessed using a five-point ordinal rating scale and compared to standard injection protocols [n = 25 each for late arterial chest, portovenous abdomen, and MDCT angiography (CTA)]. With the exception of the infrarenal inferior caval vein, all blood vessels were depicted with diagnostic image quality using the multiple-trauma protocol. Arterial luminal density was slightly but significantly smaller compared to CTA (P < 0.01). Veins and parenchymatous organs were opacified significantly better compared to all other protocols (P < 0.01). Arm artifacts reduced the density of spleen and liver parenchyma significantly (P < 0.01). Similarly high image quality is achieved for arteries using the multiple-trauma protocol compared to CTA, and parenchymatous organs are depicted with better image quality compared to specialized protocols. Arm artifacts should be avoide

    Diagnostic accuracy of coronary artery stenosis and thrombosis assessment using unenhanced multiplanar 3D post-mortem cardiac magnetic resonance imaging.

    Get PDF
    BACKGROUND A 3D sequence was introduced to unenhanced post-mortem cardiac magnetic resonance imaging (PMCMR) to enable multiplanar coronary artery image analysis and to investigate its diagnostic accuracy for the diagnosis of coronary artery stenosis and thrombosis. MATERIALS AND METHODS N = 200 forensic cases with suspected coronary artery pathology underwent 3 Tesla PMCMR (sequence used: T2 weighted transversal 3D turbo spin echo) before autopsy. Main coronary artery stenosis and thrombosis were assessed in PMCMR by multiplanar image analysis by two observers. Coronary artery histology was determined as the gold standard and compared to PMCMR. Sensitivity, specificity, negative (NPV) and positive predictive values (PPV) with 95% confidence intervals were calculated. RESULTS For all coronary arteries combined, sensitivity was 75% (PPV 73%) for the diagnosis of stenosis and 72% (PPV 71%) for the diagnosis of thrombosis. Specificity was 92% (NPV 90%) for correct diagnosis of non-existing stenosis and 97% (NPV 97%) for non-existing thrombosis. Sensitivity for correct diagnosis of different degrees of stenosis ranged between 67% and 80% (PPVs 67-82%); specificity ranged between 96% and 99% (NPVs 96-99%). CONCLUSION Multiplanar PMCMR coronary artery stenosis and thrombosis assessment based on an unenhanced T2 weighted 3D sequence provide moderate sensitivity and high specificity for the diagnosis of coronary artery stenosis and/or thrombosis. Hence, 3D T2w PMCMR cannot reliably detect existing coronary artery stenosis and thrombosis but may be particularly useful for the exclusion of stenosis or thrombosis of the main coronary arteries

    A novel multiple-trauma CT-scanning protocol using patient repositioning

    Get PDF
    Emergency CT examination is considered to be a trade-off between a short scan time and the acceptance of artifacts. This study evaluates the influence of patient repositioning on artifacts and scan time. Eighty-three consecutive multiple-trauma patients were included in this prospective study. Patients were examined without repositioning (group 1, n=39) or with patient rotation to feet-first with arms raised for scanning the chest and abdomen/pelvis (group 2, n=44). The mean scan time was 21 min in group 1 and 25 min in group 2 (P=0.01). The mean repositioning time in group 2 was 8 min. Significantly, more artifacts were observed in group 1 (with a repeated scan in 7%) than in group 2 (P=0.0001). This novel multiple- trauma CT-scanning protocol with patient repositioning achieves a higher image quality with significantly fewer artifacts than without repositioning but increases scan time slightly
    • …
    corecore