1,029 research outputs found
The Active Mirror Control of the MAGIC Telescope
One of the main design goals of the MAGIC telescopes is the very fast
repositioning in case of Gamma Ray Burst (GRB) alarms, implying a low weight of
the telescope dish. This is accomplished by using a space frame made of carbon
fiber epoxy tubes, resulting in a strong but not very rigid support structure.
Therefore it is necessary to readjust the individual mirror tiles to correct
for deformations of the dish under varying gravitational load while tracking an
object. We present the concept of the Active Mirror Control (AMC) as
implemented in the MAGIC telescopes and the actual performance reached.
Additionally we show that also telescopes using a stiff structure can benefit
from using an AMC.Comment: Contribution to the 30th ICRC, Merida, Mexico, July 2007 on behalf of
the MAGIC Collaboratio
Evolution of the synchrotron and inverse Compton emissions of the low energy peaked BL Lac object S5 0716+714
This paper presents a detailed analysis of the temporal and spectral
variability of the low-energy peaked BL Lac object S5 0716+714 with a long (~74
ks)X-ray observation performed by XMM-Newton on 2007 September 24-25. The
source experiences recurrent flares on timescales of hours. The soft X-ray
variations, up to a factor of ~4, are much stronger than the hard X-ray
variations. With higher energy, the variability amplitude increases in the soft
X-rays but decreases in the hard X-rays. The hard X-ray variability amplitude,
however, is effectively large. For the first time, we detect a soft lag of
~1000s between the soft and hard X-ray variations. The soft lags might become
larger with larger energy differences. The overall X-ray spectra exhibit a
softer-when-brighter trend, whereas the soft X-ray spectra appear to show a
harder-when-brighter trend. The concave X-ray spectra of the source can be
interpreted as the sum of the high-energy tail of the synchrotron emission,
dominating in the soft X rays, and the low-energy end of the inverse Compton
(IC) emission, contributing more in the hard X-rays. The synchrotron spectra
are steep (\Gamma~2.6), while the IC spectra are flat (\Gamma~1.2). The
synchrotron spectra appear to harden with larger synchrotron fluxes, while the
IC spectra seem to soften with larger IC fluxes. When the source brightens, the
synchrotron fluxes increase but the IC fluxes decrease. The synchrotron tail
exhibits larger flux variations but smaller spectral changes than the IC
component does. The crossing energies between the two components and the trough
energies of spectral energy distributions (SEDs) increase when the source
brightens. The X-ray spectral variability demonstrates that the synchrotron and
IC SED peaks of S5 0716+714 shift to higher energies when it brightens.Comment: published in Ap
Muonic hydrogen cascade time and lifetime of the short-lived state
Metastable muonic-hydrogen atoms undergo collisional -quenching,
with rates which depend strongly on whether the kinetic energy is above
or below the energy threshold. Above threshold, collisional
excitation followed by fast radiative
deexcitation is allowed. The corresponding short-lived component
was measured at 0.6 hPa room temperature gas pressure, with
lifetime ns (i.e.,
at liquid-hydrogen density) and population
% (per atom). In
addition, a value of the cascade time, ns, was found.Comment: 4 pages, 3 figure
X-ray emission during the muonic cascade in hydrogen
We report our investigations of X rays emitted during the muonic cascade in
hydrogen employing charge coupled devices as X-ray detectors. The density
dependence of the relative X-ray yields for the muonic hydrogen lines (K_alpha,
K_beta, K_gamma) has been measured at densities between 0.00115 and 0.97 of
liquid hydrogen density. In this density region collisional processes dominate
the cascade down to low energy levels. A comparison with recent calculations is
given in order to demonstrate the influence of Coulomb deexcitation.Comment: 5 pages, Tex, 4 figures, submitted to Physical Review Letter
FACT -- the First Cherenkov Telescope using a G-APD Camera for TeV Gamma-ray Astronomy (HEAD 2010)
Geiger-mode Avalanche Photodiodes (G-APD) bear the potential to significantly
improve the sensitivity of Imaging Air Cherenkov Telescopes (IACT). We are
currently building the First G-APD Cherenkov Telescope (FACT) by refurbishing
an old IACT with a mirror area of 9.5 square meters and construct a new, fine
pixelized camera using novel G-APDs. The main goal is to evaluate the
performance of a complete system by observing very high energy gamma-rays from
the Crab Nebula. This is an important field test to check the feasibility of
G-APD-based cameras to replace at some time the PMT-based cameras of planned
future IACTs like AGIS and CTA. In this article, we present the basic design of
such a camera as well as some important details to be taken into account.Comment: Poster shown at HEAD 2010, Big Island, Hawaii, March 1-4, 201
A novel camera type for very high energy gamma-ray astronomy based on Geiger-mode avalanche photodiodes
Geiger-mode avalanche photodiodes (G-APD) are promising new sensors for light
detection in atmospheric Cherenkov telescopes. In this paper, the design and
commissioning of a 36-pixel G-APD prototype camera is presented. The data
acquisition is based on the Domino Ring Sampling (DRS2) chip. A sub-nanosecond
time resolution has been achieved. Cosmic-ray induced air showers have been
recorded using an imaging mirror setup, in a self-triggered mode. This is the
first time that such measurements have been carried out with a complete G-APD
camera.Comment: 9 pages with 11 figure
Search for radio pulsations in LS I +61 303
Context. LS I +61 303 is a member of the select group of gamma-ray binaries:
galactic binary systems that contain a massive star and a compact object, show
a changing milliarcsecond morphology and a similar broad spectral energy
distribution (SED) that peaks at MeV-TeV energies and is modulated by the
orbital motion. The nature of the compact object is unclear in LS I +61 303, LS
5039 and HESS J0632+057, whereas PSR B1259-63 harbours a 47.74 ms radio pulsar.
Aims. A scenario in which a young pulsar wind interacts with the stellar wind
has been proposed to explain the very high energy (VHE, E > 100 GeV) gamma-ray
emission detected from LS I +61 303, although no pulses have been reported from
this system at any wavelength. We aim to find evidence of the pulsar nature of
the compact object. Methods. We performed phased array observations with the
Giant Metrewave Radio Telescope (GMRT) at 1280 MHz centred at phase 0.54.
Simultaneous data from the multi-bit phased array (PA) back-end with a sampling
time of tsamp = 128 microsec and from the polarimeter (PMT) back-end with tsamp
= 256 microsec where taken. Results. No pulses have been found in the data set,
with a minimum detectable mean flux density of \sim 0.38 mJy at 8-sigma level
for the pulsed emission from a putative pulsar with period P >2 ms and duty
cycle D = 10% in the direction of LS I +61 303. Conclusions. The detection of
posible radio pulsations will require deep and sensitive observations at
frequencies \sim0.5-5 GHz and orbital phases 0.6-0.7. However, it may be
unfeasible to detect pulses if the putative pulsar is not beamed at the Earth
or if there is a strong absorption within the binary system.Comment: 8 pages. 5 figures. Accepted for publication in Astronomy and
Astrophysic
FACT -- The G-APD revolution in Cherenkov astronomy
Since two years, the FACT telescope is operating on the Canary Island of La
Palma. Apart from its purpose to serve as a monitoring facility for the
brightest TeV blazars, it was built as a major step to establish solid state
photon counters as detectors in Cherenkov astronomy. The camera of the First
G-APD Cherenkov Telesope comprises 1440 Geiger-mode avalanche photo diodes
(G-APD), equipped with solid light guides to increase the effective light
collection area of each sensor. Since no sense-line is available, a special
challenge is to keep the applied voltage stable although the current drawn by
the G-APD depends on the flux of night-sky background photons significantly
varying with ambient light conditions. Methods have been developed to keep the
temperature and voltage dependent response of the G-APDs stable during
operation. As a cross-check, dark count spectra with high statistics have been
taken under different environmental conditions. In this presentation, the
project, the developed methods and the experience from two years of operation
of the first G-APD based camera in Cherenkov astronomy under changing
environmental conditions will be presented.Comment: Proceedings of the Nuclear Science Symposium and Medical Imaging
Conference (IEEE-NSS/MIC), 201
- âŠ