6 research outputs found

    An electronic patient-reported outcome mobile app for data collection in type a hemophilia:Design and usability study

    Get PDF
    BACKGROUND: There is currently limited evidence on the level and intensity of physical activity in individuals with hemophilia A. Mobile technologies can offer a rigorous and reliable alternative to support data collection processes but they are often associated with poor user retention. The lack of longitudinal continuity in their use can be partly attributed to the insufficient consideration of stakeholder inputs in the development process of mobile apps. Several user-centered models have been proposed to guarantee that a thorough knowledge of the end user needs is considered in the development process of mobile apps. OBJECTIVE: The aim of this study is to design and validate an electronic patient-reported outcome mobile app that requires sustained active input by individuals during POWER, an observational study that aims at evaluating the relationship between physical activity levels and bleeding in patients with hemophilia A. METHODS: We adopted a user-centered design and engaged several stakeholders in the development and usability testing of this mobile app. During the concept generation and ideation phase, we organized a need-assessment focus group (FG) with patient representatives to elicit specific design requirements for the end users. We then conducted 2 exploratory FGs to seek additional inputs for the app’s improvement and 2 confirmatory FGs to validate the app and test its usability in the field through the mobile health app usability questionnaire. RESULTS: The findings from the thematic analysis of the need-assessment FG revealed that there was a demand for sense making, for simplification of app functionalities, for maximizing integration, and for minimizing the feeling of external control. Participants involved in the later stages of the design refinement contributed to improving the design further by upgrading the app’s layout and making the experience with the app more efficient through functions such as chatbots and visual feedback on the number of hours a wearable device had been worn, to ensure that the observed data were actually registered. The end users rated the app highly during the quantitative assessment, with an average mobile health app usability questionnaire score of 5.32 (SD 0.66; range 4.44-6.23) and 6.20 (SD 0.43; range 5.72-6.88) out of 7 in the 2 iterative usability testing cycles. CONCLUSIONS: The results of the usability test indicated a high, growing satisfaction with the electronic patient-reported outcome app. The adoption of a thorough user-centered design process using several types of FGs helped maximize the likelihood of sustained retention of the app’s users and made it fit for data collection of relevant outcomes in the observational POWER study. The continuous use of the app and the actual level of engagement will be evaluated during the ongoing trial. TRIAL REGISTRATION: ClinicalTrials.gov NCT04165135; https://clinicaltrials.gov/ct2/show/NCT0416513

    Assessment of sediment toxicity in the Lagoon of Venice (Italy) using a multi-species set of bioassays

    Get PDF
    Within the framework of a Weight of Evidence (WoE) approach, a set of four toxicity bioassays involving the amphipod Corophium volutator (10 d lethality test on whole sediment), the sea urchin Paracentrotus lividus (fertilization and embryo toxicity tests on elutriate) and the pacific oyster Crassostrea gigas (embryo toxicity test on elutriate) was applied to sediments from 10 sampling sites of the Venice Lagoon (Italy). Sediments were collected during three campaigns carried out in May 2004 (spring campaign), October 2004 (autumn campaign) and February 2005 (winter campaign). Toxicity tests were performed on all sediment samples. Sediment grain-size and chemistry were measured during spring and autumn campaigns. This research investigated (i) the ability of toxicity tests in discriminating among sites with different contamination level, (ii) the occurrence of a gradient of effect among sampling sites, (iii) the possible correlation among toxicity tests, sediment chemistry, grain size and organic carbon, and (iv) the possible occurrence of toxicity seasonal variability. Sediment contamination levels were from low to moderate. No acute toxicity toward amphipods was observed, while sea urchin fertilization was affected only in few sites in just a single campaign. Short-term effects on larval development of sea urchin and oyster evidenced a clear spatial trend among sites, with increasing effects along the axis connecting the sea-inlets with the industrial area. The set of bioassays allowed the identification of a spatial gradient of effect, with decreasing toxicity from the industrial area toward the sea-inlets. Multivariate data analysis showed that the malformations of oyster embryos were significantly correlated to the industrial contamination (metals, polynuclear aromatic hydrocarbons, hexachlorobenzene and polychlorinated biphenyls), while sea urchin development to sediment concentrations of As, Cr and organic carbon. Both embryo toxicity tests were significantly affected by high ammonia concentrations found in the elutriates extracted from some mudflat and industrial sediments. No significant temporal variation of the toxicity was observed within the experimental period. Amendments to the set of bioassays, with inclusion of chronic tests, can certainly provide more reliability and consistency to the characterization of the (possible) toxic effects. (C) 2015 Elsevier Inc. All rights reserved

    Potential role of sulfide and ammonia as confounding factors in elutriate toxicity bioassays with early life stages of sea urchins and bivalves

    Get PDF
    This work reports some considerations on the possible contribution of sulfide and ammonia to the toxicity of elutriate samples of sediments from the Venice lagoon, tested with a battery of bioassays using early life stages of the sea urchin Paracentrotus lividus and the oyster Crassostrea gigas. A comparison of ammonia or sulfide concentration in the test matrix, matrix toxicity, and the sensitivity limit of bioassays for ammonia or sulfide were used in evaluating toxicity data. Results highlighted that sperm cell and embryo toxicity of elutriates were not affected by sulfides. Neither was any direct relationship shown between elutriate toxicity and ammonia concentration. Most elutriates had ammonia concentrations below the sensitivity limit of acute test methods, while the more sensitive subchronic toxicity tests were affected by ammonia interference in some samples. © 2006 Elsevier Inc. All rights reserved

    An electronic patient-reported outcome mobile app for data collection in type a hemophilia: design and usability study

    Get PDF
    Background: There is currently limited evidence on the level and intensity of physical activity in individuals with hemophilia A. Mobile technologies can offer a rigorous and reliable alternative to support data collection processes but they are often associated with poor user retention. The lack of longitudinal continuity in their use can be partly attributed to the insufficient consideration of stakeholder inputs in the development process of mobile apps. Several user-centered models have been proposed to guarantee that a thorough knowledge of the end user needs is considered in the development process of mobile apps. Objective: The aim of this study is to design and validate an electronic patient-reported outcome mobile app that requires sustained active input by individuals during POWER, an observational study that aims at evaluating the relationship between physical activity levels and bleeding in patients with hemophilia A. Methods: We adopted a user-centered design and engaged several stakeholders in the development and usability testing of this mobile app. During the concept generation and ideation phase, we organized a need-assessment focus group (FG) with patient representatives to elicit specific design requirements for the end users. We then conducted 2 exploratory FGs to seek additional inputs for the app’s improvement and 2 confirmatory FGs to validate the app and test its usability in the field through the mobile health app usability questionnaire. Results: The findings from the thematic analysis of the need-assessment FG revealed that there was a demand for sense making, for simplification of app functionalities, for maximizing integration, and for minimizing the feeling of external control. Participants involved in the later stages of the design refinement contributed to improving the design further by upgrading the app’s layout and making the experience with the app more efficient through functions such as chatbots and visual feedback on the number of hours a wearable device had been worn, to ensure that the observed data were actually registered. The end users rated the app highly during the quantitative assessment, with an average mobile health app usability questionnaire score of 5.32 (SD 0.66; range 4.44-6.23) and 6.20 (SD 0.43; range 5.72-6.88) out of 7 in the 2 iterative usability testing cycles. Conclusions: The results of the usability test indicated a high, growing satisfaction with the electronic patient-reported outcome app. The adoption of a thorough user-centered design process using several types of FGs helped maximize the likelihood of sustained retention of the app’s users and made it fit for data collection of relevant outcomes in the observational POWER study. The continuous use of the app and the actual level of engagement will be evaluated during the ongoing trial
    corecore