3,832 research outputs found

    Possible mechanisms of electronic phase separation in oxide interfaces

    Full text link
    LaAlO3/SrTiO3 ad LaTiO3/SrTiO3 interfaces are known to host a strongly inhomogeneous (nearly) two-dimensional electron gas (2DEG). In this work we present three unconventional electronic mechanisms of electronic phase separation (EPS) in a 2DEG as a possible source of inhomogeneity in oxide interfaces. Common to all three mechanisms is the dependence of some (interaction) potential on the 2DEG's density. We first consider a mechanism resulting from a sizable density-dependent Rashba spin-orbit coupling. Next, we point out that an EPS may also occur in the case of a density-dependent superconducting pairing interaction. Finally, we show that the confinement of the 2DEG to the interface by a density-dependent, self-consistent electrostatic potential can by itself cause an EPS.Comment: 4 pages and 4 figures, Proceedings of the International Conference "Superstripes 2014", 25-31 July 2015, Erice, Ital

    New distinguished classes of spectral spaces: a survey

    Full text link
    In the present survey paper, we present several new classes of Hochster's spectral spaces "occurring in nature", actually in multiplicative ideal theory, and not linked to or realized in an explicit way by prime spectra of rings. The general setting is the space of the semistar operations (of finite type), endowed with a Zariski-like topology, which turns out to be a natural topological extension of the space of the overrings of an integral domain, endowed with a topology introduced by Zariski. One of the key tool is a recent characterization of spectral spaces, based on the ultrafilter topology, given in a paper by C. Finocchiaro in Comm. Algebra 2014. Several applications are also discussed

    A mini-phoswich scintillator as a possible stop detector for the NUMEN project

    Get PDF
    AbstractIn the framework of the NUMEN project, aimed at the investigation of the nuclear matrix elements connected to the neutrinoless double beta decay by means of the Double Charge Exchange nuclear reactions (Cappuzzello et al., 2015), a high granularity stop detector for heavy ions is needed. It has to allow the identification of ions up to Z≈10 while maintaining a total energy resolution around 2%. As the use of silicon detectors is not possible, due to their poor radiation hardness, scintillators are being investigated as possible candidates. In this paper we show a promising result obtained using a plastic+inorganic phoswich scintillator readout by means of a Silicon Photo Multiplier

    COVID-19 and myocarditis: a systematic review and overview of current challenges

    Get PDF
    Myocardial inflammation in COVID-19 has been documented. Its pathogenesis is not fully elucidated, but the two main theories foresee a direct role of ACE2 receptor and a hyperimmune response, which may also lead to isolated presentation of COVID-19-mediated myocarditis. The frequency and prognostic impact of COVID-19-mediated myocarditis is unknown. This review aims to summarise current evidence on this topic. We performed a systematic review of MEDLINE and Cochrane Library (1/12/19–30/09/20). We also searched clinicaltrials.gov for unpublished studies testing therapies with potential implication for COVID-19-mediated cardiovascular complication. Eligible studies had laboratory confirmed COVID-19 and a clinical and/or histological diagnosis of myocarditis by ESC or WHO/ISFC criteria. Reports of 38 cases were included (26 male patients, 24 aged < 50 years). The first histologically proven case was a virus-negative lymphocytic myocarditis; however, biopsy evidence of myocarditis secondary to SARS-CoV-2 cardiotropism has been recently demonstrated. Histological data was found in 12 cases (8 EMB and 4 autopsies) and CMR was the main imaging modality to confirm a diagnosis of myocarditis (25 patients). There was a substantial variability in biventricular systolic function during the acute episode and in therapeutic regimen used. Five patients died in hospital. Cause-effect relationship between SARS-CoV-2 infection and myocarditis is difficult to demonstrate. However, current evidence demonstrates myocardial inflammation with or without direct cardiomyocyte damage, suggesting different pathophysiology mechanisms responsible of COVID-mediated myocarditis. Established clinical approaches should be pursued until future evidence support different actions. Large multicentre registries are advisable to elucidate further

    Comparison of different calculation techniques for absorbed dose assessment in patient specific peptide receptor radionuclide therapy

    Get PDF
    Aim: The present work concerns the comparison of the performances of three systems for dosimetry in RPT that use different techniques for absorbed dose calculation (organ-level dosimetry, voxel-level dose kernel convolution and Monte Carlo simulations). The aim was to assess the importance of the choice of the most adequate calculation modality, providing recommendations about the choice of the computation tool. Methods: The performances were evaluated both on phantoms and patients in a multi-level approach. Different phantoms filled with a 177Lu-radioactive solution were used: a homogeneous cylindrical phantom, a phantom with organ-shaped inserts and two cylindrical phantoms with inserts different for shape and volume. A total of 70 patients with NETs treated by PRRT with 177Lu-DOTATOC were retrospectively analysed. Results: The comparisons were performed mainly between the mean values of the absorbed dose in the regions of interest. A general better agreement was obtained between Dose kernel convolution and Monte Carlo simulations results rather than between either of these two and organ-level dosimetry, both for phantoms and patients. Phantoms measurements also showed the discrepancies mainly depend on the geometry of the inserts (e.g. shape and volume). For patients, differences were more pronounced than phantoms and higher inter/intra patient variability was observed. Conclusion: This study suggests that voxel-level techniques for dosimetry calculation are potentially more accurate and personalized than organ-level methods. In particular, a voxel-convolution method provides good results in a short time of calculation, while Monte Carlo based computation should be conducted with very fast calculation systems for a possible use in clinics, despite its intrinsic higher accuracy. Attention to the calculation modality is recommended in case of clinical regions of interest with irregular shape and far from spherical geometry, in which Monte Carlo seems to be more accurate than voxel-convolution methods

    Thermal neutron conversion by high purity 10B-enriched layers: PLD-growth, thickness-dependence and neutron-detection performances

    Get PDF
    Neutron applications and detection are of paramount importance in industry, medicine, scientific research, homeland security, production of extreme UV optics and so on. Neutron detection requires a converter element that, as a result of its interaction with neutrons, produces reaction products (mainly charged particles) whose detection can be correlated with the neutron flux. Reduced availability and increased cost of the most used converter element, 3He, have triggered research efforts for alternative materials, proper deposition methods and new detector architectures. 10B converter is a valid alternative to 3He thanks to its high thermal neutron cross section and relatively high Q value. In this paper we report on the room temperature Pulsed Laser Deposition (PLD) of high quality and uniform 10B films with the expected density, different thickness values (0.5, 1.0, 1.2, 1.5 and 2.0 μm) and uniform thickness over a circular area of about 30 mm in diameter. Additionally, they are adherent to the substrate with a negligible presence of contaminants. The conversion properties of such 10B coatings coupled to a Si solid state detector are studied upon exposure to a neutron flux from an Am-Be neutron source (2.2·106 n/s). The experimental results, compared with spectra simulated by using a GEANT4 code, present a good agreement and efficiencies of the order of a few percent
    • …
    corecore