95 research outputs found

    Global Sourcing under Imperfect Capital Markets

    Get PDF
    We develop a simple model to study the interactions between a supplier’s financial constraints and contract incompleteness in a vertical relationship. Production complexity increases the extent of contract incompleteness and the hold-up problem, which generates a cost when the supplier needs financial participation from the downstream firm. Vertical integration alleviates the impact of financial constraints but reduces the supplier’s incentives. We apply the model to an analysis of multinational firms’ sourcing strategies and predict that (1) complex and specific inputs are more likely to be sourced from financially developed countries and (2) multinationals are more likely to integrate suppliers located in countries with poor financial institutions, especially when trade involves complex goods. We examine and validate these predictions using firm-level trade data on multinational firms with operations in France. We provide evidence that financial development generates a comparative advantage in the supply of complex goods. Moreover, we find higher shares of intra-firm imports of complex inputs from countries with a lower level of financial development. The findings are robust to different measures of complexity and specificity, and are not driven by industry differences in fixed costs or traditional measures of external financial dependence. Quantitatively, we find that financial development is as important as contract enforcement in alleviating hold-up problems.Sourcing, FDI, financial constraints, contractual frictions.

    Mirrors for slow neutrons from holographic nanoparticle-polymer free-standing film-gratings

    Full text link
    We report on successful tests of holographically arranged grating-structures in nanoparticle-polymer composites in the form of 100 microns thin free-standing films, i.e. without sample containers or covers that could cause unwanted absorption/incoherent scattering of very-cold neutrons. Despite their large diameter of 2 cm, the flexible materials are of high optical quality and yield mirror-like reflectivity of about 90% for neutrons of 4.1 nm wavelength

    Neutron optical beam splitter from holographically structured nanoparticle-polymer composites

    Full text link
    We report a breakthrough in the search for versatile diffractive elements for cold neutrons. Nanoparticles are spatially arranged by holographical means in a photopolymer. These grating structures show remarkably efficient diffraction of cold neutrons up to about 50% for effective thicknesses of only 200 micron. They open up a profound perspective for next generation neutron-optical devices with the capability to tune or modulate the neutron diffraction efficiency.Comment: 4 pages, 2 figure

    Improved water vapour spectroscopy in the 4174-4300 cm⁻¹ region and its impact on SCIAMACHY HDO/H₂O measurements

    Get PDF
    The relative abundance of the heavy water isotopologue HDO provides a deeper insight into the atmospheric hydrological cycle. The SCanning Imaging Absorption spectroMeter for Atmospheric CartograpHY (SCIAMACHY) allows for global retrievals of the ratio HDO/HO in the 2.3 micron wavelength range. However, the spectroscopy of water lines in this region remains a large source of uncertainty for these retrievals. We therefore evaluate and improve the water spectroscopy in the range 4174–4300 cm⁻¹ and test if this reduces systematic uncertainties in the SCIAMACHY retrievals of HDO/H₂O. We use a laboratory spectrum of water vapour to fit line intensity, air broadening and wavelength shift parameters. The improved spectroscopy is tested on a series of ground-based high resolution FTS spectra as well as on SCIAMACHY retrievals of H2O and the ratio HDO/H₂O. We find that the improved spectroscopy leads to lower residuals in the FTS spectra compared to HITRAN 2008 and Jenouvrier et al. (2007) spectroscopy, and the retrievals become more robust against changes in the retrieval window. For both the FTS and SCIAMACHY measurements, the retrieved total H₂O columns decrease by 2–4% and we find a negative shift of the HDO/H₂O ratio, which for SCIAMACHY is partly compensated by changes in the retrieval setup and calibration software. The updated SCIAMACHY HDO/H₂O product shows somewhat steeper latitudinal and temporal gradients and a steeper Rayleigh distillation curve, strengthening previous conclusions that current isotope-enabled general circulation models underestimate the variability in the near-surface HDO/H₂O ratio

    Circulating adrenomedullin estimates survival and reversibility of organ failure in sepsis: the prospective observational multinational Adrenomedullin and Outcome in Sepsis and Septic Shock-1 (AdrenOSS-1) study

    Get PDF
    Background: Adrenomedullin (ADM) regulates vascular tone and endothelial permeability during sepsis. Levels of circulating biologically active ADM (bio-ADM) show an inverse relationship with blood pressure and a direct relationship with vasopressor requirement. In the present prospective observational multinational Adrenomedullin and Outcome in Sepsis and Septic Shock 1 (, AdrenOSS-1) study, we assessed relationships between circulating bio-ADM during the initial intensive care unit (ICU) stay and short-term outcome in order to eventually design a biomarker-guided randomized controlled trial. Methods: AdrenOSS-1 was a prospective observational multinational study. The primary outcome was 28-day mortality. Secondary outcomes included organ failure as defined by Sequential Organ Failure Assessment (SOFA) score, organ support with focus on vasopressor/inotropic use, and need for renal replacement therapy. AdrenOSS-1 included 583 patients admitted to the ICU with sepsis or septic shock. Results: Circulating bio-ADM levels were measured upon admission and at day 2. Median bio-ADM concentration upon admission was 80.5 pg/ml [IQR 41.5-148.1 pg/ml]. Initial SOFA score was 7 [IQR 5-10], and 28-day mortality was 22%. We found marked associations between bio-ADM upon admission and 28-day mortality (unadjusted standardized HR 2.3 [CI 1.9-2.9]; adjusted HR 1.6 [CI 1.1-2.5]) and between bio-ADM levels and SOFA score (p < 0.0001). Need of vasopressor/inotrope, renal replacement therapy, and positive fluid balance were more prevalent in patients with a bio-ADM > 70 pg/ml upon admission than in those with bio-ADM ≤ 70 pg/ml. In patients with bio-ADM > 70 pg/ml upon admission, decrease in bio-ADM below 70 pg/ml at day 2 was associated with recovery of organ function at day 7 and better 28-day outcome (9.5% mortality). By contrast, persistently elevated bio-ADM at day 2 was associated with prolonged organ dysfunction and high 28-day mortality (38.1% mortality, HR 4.9, 95% CI 2.5-9.8). Conclusions: AdrenOSS-1 shows that early levels and rapid changes in bio-ADM estimate short-term outcome in sepsis and septic shock. These data are the backbone of the design of the biomarker-guided AdrenOSS-2 trial. Trial registration: ClinicalTrials.gov, NCT02393781. Registered on March 19, 2015

    The 2009 edition of the GEISA spectroscopic database

    Get PDF
    The updated 2009 edition of the spectroscopic database GEISA (Gestionet Etudedes Informations Spectroscopiques Atmospheriques ; Management and Study of Atmospheric Spectroscopic Information) is described in this paper. GEISA is a computer-accessible system comprising three independent sub-databases devoted, respectively, to: line parameters, infrared and ultraviolet/visible absorption cross-sections, microphysical and optical properties of atmospheric aerosols. In this edition, 50 molecules are involved in the line parameters sub-database, including 111 isotopologues, for a total of 3,807,997 entries, in the spectral range from 10-6 to 35,877.031cm-1. GEISA, continuously developed and maintained at LMD (Laboratoirede Meteorologie Dynamique, France) since 1976, is implemented on the IPSL/CNRS(France) ‘‘Ether’’ Products and Services Centre WEB site (http://ether.ipsl.jussieu.fr), where all archived spectroscopic data can be handled through general and user friendly associated managements of software facilities. More than 350 researchers are registered for online use of GEISA
    corecore