6 research outputs found

    Clinical and echocardiographic parameters predicting 1- and 2-year mortality after transcatheter aortic valve implantation

    No full text
    Background: Transcatheter aortic valve implantation (TAVI) has become a standard treatment option for patients with symptomatic aortic stenosis. Elderly high-risk patients treated with TAVI have a high residual mortality due to preexisting comorbidities. Knowledge of factors predicting futility after TAVI is sparse and clinical tools to aid the preoperative evaluation are lacking. The aim of this study was to evaluate if echocardiographic measures, including speckle-tracking analysis, in addition to clinical parameters, could aid in the prediction of mortality beyond 30 days after TAVI. Methods: This prospective observational cohort study included 227 patients treated with TAVI at the University Hospital of North Norway, Tromsø and Oslo University Hospital, Rikshospitalet from February 2010 to June 2013. All the patients underwent preoperative echocardiographic evaluation with retrospective speckle-tracking analysis. Primary endpoints were 1- and 2-year mortality beyond 30 days after TAVI. Results: All-cause 1- and 2-year mortality beyond 30 days after TAVI was 12.1 and 19.5%, respectively. Predictors of 1-year mortality beyond 30 days were body mass index [hazard ratio (HR): 0.88, 95% CI: 0.80–0.98, p = 0.018], previous myocardial infarction (HR: 2.69, 95% CI: 1.14–6.32, p = 0.023), and systolic pulmonary artery pressure ≥ 60 mm Hg (HR: 5.93, 95% CI: 1.67–21.1, p = 0.006). Moderate-to-severe mitral regurgitation (HR: 2.93, 95% CI: 1.53–5.63, p = 0.001), estimated glomerular filtration rate (HR: 0.98, 95% CI: 0.96–0.99, p = 0.002), and chronic obstructive pulmonary disease (HR: 1.9, 95% CI: 1.01–3.58, p = 0.046) were predictors of 2-year mortality. Conclusion: Both the clinical and echocardiographic parameters should be considered when evaluating high-risk patients for TAVI, as both are predictive of 1-and 2-year mortality. Our results support the importance of individual risk assessment using a multidisciplinary, multimodal, and individual approach

    Clinical and echocardiographic parameters predicting 1- and 2-year mortality after transcatheter aortic valve implantation

    Get PDF
    Background: Transcatheter aortic valve implantation (TAVI) has become a standard treatment option for patients with symptomatic aortic stenosis. Elderly high-risk patients treated with TAVI have a high residual mortality due to preexisting comorbidities. Knowledge of factors predicting futility after TAVI is sparse and clinical tools to aid the preoperative evaluation are lacking. The aim of this study was to evaluate if echocardiographic measures, including speckle-tracking analysis, in addition to clinical parameters, could aid in the prediction of mortality beyond 30 days after TAVI. Methods: This prospective observational cohort study included 227 patients treated with TAVI at the University Hospital of North Norway, Tromsø and Oslo University Hospital, Rikshospitalet from February 2010 to June 2013. All the patients underwent preoperative echocardiographic evaluation with retrospective speckle-tracking analysis. Primary endpoints were 1- and 2-year mortality beyond 30 days after TAVI. Results: All-cause 1- and 2-year mortality beyond 30 days after TAVI was 12.1 and 19.5%, respectively. Predictors of 1-year mortality beyond 30 days were body mass index [hazard ratio (HR): 0.88, 95% CI: 0.80–0.98, p = 0.018], previous myocardial infarction (HR: 2.69, 95% CI: 1.14–6.32, p = 0.023), and systolic pulmonary artery pressure ≥ 60 mm Hg (HR: 5.93, 95% CI: 1.67–21.1, p = 0.006). Moderate-to-severe mitral regurgitation (HR: 2.93, 95% CI: 1.53–5.63, p = 0.001), estimated glomerular filtration rate (HR: 0.98, 95% CI: 0.96–0.99, p = 0.002), and chronic obstructive pulmonary disease (HR: 1.9, 95% CI: 1.01–3.58, p = 0.046) were predictors of 2-year mortality. Conclusion: Both the clinical and echocardiographic parameters should be considered when evaluating high-risk patients for TAVI, as both are predictive of 1-and 2-year mortality. Our results support the importance of individual risk assessment using a multidisciplinary, multimodal, and individual approach

    Predictors of early mortality after transcatheter aortic valve implantation

    Get PDF
    To investigate whether preoperative echocardiographic evaluation of ventricular function, especially right ventricular systolic and diastolic parameters including speckle-tracking analysis, could aid in the prediction of 30-day mortality after transcatheter aortic valve implantation (TAVI) in patients with aortic stenosis.This is a prospective observational cohort study including 227 patients accepted for TAVI at the University Hospital of North Norway and Oslo University Hospital from February 2010 through June 2013. All patients underwent preoperative transthoracic echocardiography with retrospective speckle-tracking analysis. Primary endpoint was all-cause 30-day mortality.All-cause 30-day mortality was 8.7 % (n = 19). Independent predictors of 30-day mortality were systolic pulmonary arterial pressure (SPAP) > 60 mm Hg (HR: 7.7, 95% CI: 1.90 to 31.3), heart failure (HR: 2.9, 95% CI: 1.1 to 7.78), transapical access (HR: 3.8, 95% CI: 1.3 to 11.2), peripheral artery disease (HR: 6.0, 95% CI: 2.0 to 18.0) and body mass index (HR: 0.73, 95% CI: 0.61 to 0.87). C-statistic for the model generated was 0.91 (95% CI: 0.85 to 0.98). Besides elevated SPAP, no other echocardiographic measurements were found to be an independent predictor of early mortality.Except for elevated systolic pulmonary artery pressure, our data suggests that clinical rather than echocardiographic parameters are useful predictors of 30-day mortality after TAVI

    Predictors of early mortality after transcatheter aortic valve implantation

    Get PDF
    Objectives To investigate whether preoperative echocardiographic evaluation of ventricular function, especially right ventricular systolic and diastolic parameters including speckle-tracking analysis, could aid in the prediction of 30-day mortality after transcatheter aortic valve implantation (TAVI) in patients with aortic stenosis. Methods This is a prospective observational cohort study including 227 patients accepted for TAVI at the University Hospital of North Norway and Oslo University Hospital from February 2010 through June 2013. All patients underwent preoperative transthoracic echocardiography with retrospective speckle-tracking analysis. Primary endpoint was all-cause 30-day mortality. Results All-cause 30-day mortality was 8.7 % (n = 19). Independent predictors of 30-day mortality were systolic pulmonary arterial pressure (SPAP) > 60 mm Hg (HR: 7.7, 95% CI: 1.90 to 31.3), heart failure (HR: 2.9, 95% CI: 1.1 to 7.78), transapical access (HR: 3.8, 95% CI: 1.3 to 11.2), peripheral artery disease (HR: 6.0, 95% CI: 2.0 to 18.0) and body mass index (HR: 0.73, 95% CI: 0.61 to 0.87). C-statistic for the model generated was 0.91 (95% CI: 0.85 to 0.98). Besides elevated SPAP, no other echocardiographic measurements were found to be an independent predictor of early mortality. Conclusion Except for elevated systolic pulmonary artery pressure, our data suggests that clinical rather than echocardiographic parameters are useful predictors of 30-day mortality after TAVI

    Risk scores for prediction of 30-day mortality after transcatheter aortic valve implantation: Results from a two-center study in Norway

    No full text
    Objectives Transcatheter aortic valve implantation (TAVI)-specific risk scores have been developed based on large registry studies. Our aim was to evaluate how both surgical and novel TAVI risk scores performed in predicting all cause 30-day mortality. In addition, we wanted to explore the validity of our own previously developed model in a separate and more recent cohort. Methods The derivation cohort included patients not eligible for open surgery treated with TAVI at the University Hospital of North Norway (UNN) and Oslo University Hospital (OUS) from February 2010 through June 2013. From this cohort, a logistic prediction model (UNN/OUS) for all cause 30-day mortality was developed. The validation cohort consisted of patients not included in the derivation cohort and treated with TAVI at UNN between June 2010 and April 2017. EuroSCORE, Logistic EuroSCORE, EurosSCORE 2, STS score, German AV score, OBSERVANT score, IRRMA score, and FRANCE-2 score were calculated for both cohorts. The discriminative accuracy of each score, including our model, was evaluated by receiver operating characteristic (ROC) analysis and compared using DeLong test where P< .05 was considered statistically significant. Results The derivation cohort consisted of 218 and the validation cohort of 241 patients. Our model showed statistically significant better accuracy than all other scores in the derivation cohort. In the validation cohort, the FRANCE-2 had a significantly higher predictive accuracy compared to all scores except the IRRMA and STS score. Our model showed similar results. Conclusion Existing risk scores have shown limited accuracy in predicting early mortality after TAVI. Our results indicate that TAVI-specific risk scores might be useful when evaluating patients for TAVI

    Risk scores for prediction of 30-day mortality after transcatheter aortic valve implantation: Results from a two-center study in Norway

    Get PDF
    Objectives: Transcatheter aortic valve implantation (TAVI)-specific risk scores have been developed based on large registry studies. Our aim was to evaluate how both surgical and novel TAVI risk scores performed in predicting all cause 30-day mortality. In addition, we wanted to explore the validity of our own previously developed model in a separate and more recent cohort. Methods: The derivation cohort included patients not eligible for open surgery treated with TAVI at the University Hospital of North Norway (UNN) and Oslo University Hospital (OUS) from February 2010 through June 2013. From this cohort, a logistic prediction model (UNN/OUS) for all cause 30-day mortality was developed. The validation cohort consisted of patients not included in the derivation cohort and treated with TAVI at UNN between June 2010 and April 2017. EuroSCORE, Logistic EuroSCORE, EurosSCORE 2, STS score, German AV score, OBSERVANT score, IRRMA score, and FRANCE-2 score were calculated for both cohorts. The discriminative accuracy of each score, including our model, was evaluated by receiver operating characteristic (ROC) analysis and compared using DeLong test where P Results: The derivation cohort consisted of 218 and the validation cohort of 241 patients. Our model showed statistically significant better accuracy than all other scores in the derivation cohort. In the validation cohort, the FRANCE-2 had a significantly higher predictive accuracy compared to all scores except the IRRMA and STS score. Our model showed similar results. Conclusion: Existing risk scores have shown limited accuracy in predicting early mortality after TAVI. Our results indicate that TAVI-specific risk scores might be useful when evaluating patients for TAVI
    corecore