18 research outputs found

    Design and Performance Analysis of a Non-Standard EPICS Fast Controller

    Full text link
    The large scientific projects present new technological challenges, such as the distributed control over a communication network. In particular, the middleware EPICS is the most extended communication standard in particle accelerators. The integration of modern control architectures in these EPICS networks is becoming common, as for example for the PXI/PXIe and xTCA hardware alternatives. In this work, a different integration procedure for PXIe real time controllers from National Instruments is proposed, using LabVIEW as the design tool. This methodology is considered and its performance is analyzed by means of a set of laboratory experiments. This control architecture is proposed for achieving the implementation requirements of the fast controllers, which need an important amount of computational power and signal processing capability, with a tight real-time demand. The present work studies the advantages and drawbacks of this methodology and presents its comprehensive evaluation by means of a laboratory test bench, designed for the application of systematic tests. These tests compare the proposed fast controller performance with a similar system implemented using an standard EPICS IOC provided by the CODAC system.Comment: This is the extended version of the Conference Record presented in the IEEE Real-Time Conference 2014, Nara, Japan. This paper has been submitted to the IEEE Transactions on Nuclear Scienc

    Precision fish farming: a new framework to improve production in aquaculture

    Get PDF
    Aquaculture production of finfish has seen rapid growth in production volume and economic yield over the last decades, and is today a key provider of seafood. As the scale of production increases, so does the likelihood that the industry will face emerging biological, economic and social challenges that may influence the ability to maintain ethically sound, productive and environmentally friendly production of fish. It is therefore important that the industry aspires to monitor and control the effects of these challenges to avoid also upscaling potential problems when upscaling production. We introduce the Precision Fish Farming (PFF) concept whose aim is to apply control-engineering principles to fish production, thereby improving the farmer's ability to monitor, control and document biological processes in fish farms. By adapting several core principles from Precision Livestock Farming (PLF), and accounting for the boundary conditions and possibilities that are particular to farming operations in the aquatic environment, PFF will contribute to moving commercial aquaculture from the traditional experience-based to a knowledge-based production regime. This can only be achieved through increased use of emerging technologies and automated systems. We have also reviewed existing technological solutions that could represent important components in future PFF applications. To illustrate the potential of such applications, we have defined four case studies aimed at solving specific challenges related to biomass monitoring, control of feed delivery, parasite monitoring and management of crowding operations

    BioMAX the first macromolecular crystallography beamline at MAX IV Laboratory

    Get PDF
    BioMAX is the first macromolecular crystallography beamline at the MAX IV Laboratory 3 GeV storage ring, which is the first operational multi bend achromat storage ring. Due to the low emittance storage ring, BioMAX has a parallel, high intensity X ray beam, even when focused down to 20 mm 5 mm using the bendable focusing mirrors. The beam is tunable in the energy range 5 25 keV using the in vacuum undulator and the horizontally deflecting doublecrystal monochromator. BioMAX is equipped with an MD3 diffractometer, an ISARA high capacity sample changer and an EIGER 16M hybrid pixel detector. Data collection at BioMAX is controlled using the newly developed MXCuBE3 graphical user interface, and sample tracking is handled by ISPyB. The computing infrastructure includes data storage and processing both at MAX IV and the Lund University supercomputing center LUNARC. With state of the art instrumentation, a high degree of automation, a user friendly control system interface and remote operation, BioMAX provides an excellent facility for most macromolecular crystallography experiments. Serial crystallography using either a high viscosity extruder injector or the MD3 as a fixedtarget scanner is already implemented. The serial crystallography activities at MAX IV Laboratory will be further developed at the microfocus beamline MicroMAX, when it comes into operation in 2022. MicroMAX will have a 1 mm x 1 mm beam focus and a flux up to 10 15 photons s 1 with main applications in serial crystallography, room temperature structure determinations and time resolved experiment

    ISHN ion source control system. First steps toward an EPICS based ess-bilbao accelerator control system

    No full text
    ISHN (Ion Source Hydrogen Negative) consists of a Penning type ion source in operation at ESS-Bilbao facilities. From the control point of view, this source is representative of the first steps and decisions taken towards the general control architecture of the whole accelerator to be built. The ISHN main control system is based on a PXI architecture, under a real-time controller which is programmed using LabVIEW. This system, with additional elements, is connected to the general control system. The whole system is based on EPICS for the control network, and the modularization of the communication layers of the accelerator plays an important role in the proposed control architecture. © 1963-2012 IEEE.Peer Reviewe

    Actividad de los centros de detección precoz neonatal de errores congénitos del metabolismo en España en el periodo 2000-2008

    No full text
    Los Programas de Cribado Neonatal (PCN) están dirigidos a la identificación presintomática de determinados estados genéticos o metabólicos, mediante el uso de pruebas que puedan ser aplicadas a toda la población de recién nacidos

    Actividad de los centros de detección precoz neonatal de errores congénitos del metabolismo en España en el periodo 2000-2008

    No full text
    Los Programas de Cribado Neonatal (PCN) están dirigidos a la identificación presintomática de determinados estados genéticos o metabólicos, mediante el uso de pruebas que puedan ser aplicadas a toda la población de recién nacidos

    Adjustable ECR Ion Source Control System: Ion Source Hydrogen Positive Project

    No full text
    ISHP (Ion Source Hydrogen Positive) project consists of a highly versatile ECR type ion source. It has been built for several purposes, on the one hand, to serve as a workbench to test accelerator related technologies and validate in-house made developments, at the first stages. On the other hand, to design an ion source valid as the first step in an actual LINAC. Since this paper is focused on the control system of ISHP, besides the ion source, all the hardware and its control architecture is presented. Nowadays the ion source is able to generate a pulse of positive ions of Hydrogen from 2 mu s to a few range with a repetition rate ranging from 1 Hz to 50 Hz with a maximum of 45 mA of current. Furthermore, the first experiments with White Rabbit (WR) synchronization system are presented

    Adjustable ECR Ion Source Control System Ion Source Hydrogen Positive Project

    No full text
    ISHP (Ion Source Hydrogen Positive) project consists of a highly versatile ECR type ion source. It has been built for several purposes, on the one hand, to serve as a workbench to test accelerator related technologies and validate in-house made developments, at the first stages. On the other hand, to design an ion source valid as the first step in an actual LINAC. Since this paper is focused on the control system of ISHP, besides the ion source, all the hardware and its control architecture is presented. Nowadays the ion source is able to generate a pulse of positive ions of Hydrogen from 2 mu s to a few range with a repetition rate ranging from 1 Hz to 50 Hz with a maximum of 45 mA of current. Furthermore, the first experiments with White Rabbit (WR) synchronization system are presented
    corecore