30 research outputs found
Pre- and Post-Surgery analysis of functional capacity and quality of life of patienst with Osteoarthritis submitted to Total Hip Artroplasty
OBJECTIVE: To evaluate the functional capacity of the hip articulation and the quality of life of patients with osteoarthritis submitted to total artroplasty. METHODS: 12 patients were assessed through the questionnaire Harris Hip Score (modified/scale of 0-95 points) and goniometry in the pre- and post-surgery of total hip artroplasty. RESULTS: The pre-surgery questionnaire score was 39.7 and in the post-surgery the average score reached 74.1 points (p = 0.000001). The range of motion of the hip was incomplete in all the movement arches in the pre-surgery, but in the post-surgery this value increased significantly in flexion (p = 0.007), extension (p = 0.02), abduction (p = 0.001, medial rotation (p = 0.0002) and lateral rotation (p = 0.01); only the aduction movement was not significantly increased (p = 0.08). CONCLUSIONS: Total hip artroplasty reliefs patients pain, improves daily life activities and increases the hip range of motion; patients, however, relate fear and insecurity in the accomplishment of those activities.OBJETIVO: avaliar a capacidade funcional da articulação do quadril e a qualidade de vida de pacientes portadores de osteoartrose submetidos à artroplastia total. MÉTODOS: foram avaliados 12 pacientes através do questionário Harris Hip Score (modificado/ escala de 0-95 pontos) e goniometria no pré e pós-operatório de artroplastia total de quadril. RESULTADOS: a amplitude de movimento mostrou-se incompleta em todos os arcos de movimento no pré-operatório. No pós-operatório os valores aumentaram significativamente na flexão (p=0,007), extensão (p=0,02), abdução (p=0,001), rotação medial (p=0,0002) e lateral (p=0,01), apenas o aumento do movimento de adução de quadril não foi significativo (p=0,08). A medida do escore obtido através do questionário no pré-operatório foi 39,7 pontos e no pós-operatório 74,1 pontos (P<0,000001). CONCLUSÕES: a artroplastia total do quadril proporciona ao paciente alívio da dor, melhora na realização das atividades da vida diária e aumento da amplitude do movimento articular do quadril. Os pacientes, porém, relatam medo e insegurança na realização dessas atividades.Universidade de FrancaUniversidade de Franca departamento de fisioterapia geriátricaUNIFESP-EPM Departamento de ortopedia e traumatologiaUNIFESP, EPM, Depto. de ortopedia e traumatologiaSciEL
Fractures of the proximal femur: correlation with vitamin D receptor gene polymorphism
Fractures are the feared consequences of osteoporosis and fractures of the proximal femur (FPF) are those that involve the highest morbidity and mortality. Thus far, evaluation of bone mineral density (BMD) is the best way to determine the risk of fracture. Genetic inheritance, in turn, is one of the major determinants of BMD. A correlation between different genotypes of the vitamin D receptor (VDR) and BMD has been recently reported. On this basis, we decided to determine the importance of the determination of VDR genotype in the presence of an osteoporotic FPF in a Brazilian population. We studied three groups: group I consisted of 73 elderly subjects older than 65 years (78.5 ± 7.2 years) hospitalized for nonpathological FPF; group II consisted of 50 individuals older than 65 years (72.9 ± 5.2 years) without FPF and group III consisted of 98 young normal Brazilian individuals aged 32.6 ± 6.6 years (mean ± SD). Analysis of VDR gene polymorphism by restriction fragment length polymorphism (RFLP) was performed by PCR amplification followed by BsmI digestion of DNA isolated from peripheral leukocytes. The genotype distribution in group I was 20.5% BB, 42.5% Bb and 37% bb and did not differ significantly from the values obtained for group II (16% BB, 36% Bb and 48% bb) or for group III (10.2% BB, 47.6% Bb and 41.8% bb). No differences in genotype distribution were observed between sexes or between the young and elderly groups. We conclude that determination of VDR polymorphism is of no practical use for the prediction of FPF. Other nongenetic factors probably start to affect bone mass, the risk to fall and consequently the occurrence of osteoporotic fractures with advancing age.A01Universidade Federal de São Paulo (UNIFESP)Hospital do Servidor Público Estadual de São PauloUNIFESPSciEL
Evaluation of the function and quality of life of patients submitted to girdlestone's resection arthroplasty
OBJECTIVES: To evaluate function and quality of life of patients submitted to Girdlestone's arthroplasty, and to compare outcomes between unilateral Girdlestone's group with the group with contralateral total hip prosthesis. METHODS: Cross-sectional study where 9 patients were evaluated with unilateral Girdlestone's and 3 with Girdlestone's in one hip and contralateral total hip prosthesis. The evaluation consisted in filling in a generic questionnaire on quality of life SF-36 and a specific questionnaire for hip function Harris Hip Score (HHS). The comparison between groups was made by using the Student's t-test and the Fisher's test. RESULTS: The patients of the unilateral Girdlestone's group presented a higher number of SF-36 domains classified as high, although 77.8% of these showed poor results on the HHS. All patients had a leg-length discrepancy and positive Trendelenburg's test, which led to limping gait in 11 of 12 patients evaluated. Of these, only 6 underwent physiotherapy after surgery. CONCLUSION: Girdlestone's postoperative quality of life and function in a Brazilian population still requires further studies, because these outcomes are indicative of study variables' behavior and cannot be regarded as definite.OBJETIVOS: Avaliar a função e a qualidade de vida dos pacientes pós-artroplastia de Girdlestone e comparar os resultados entre os grupos Girdlestone unilateral e o grupo com prótese total de quadril contralateral. MÉTODOS: estudo transversal no qual foram avaliados 9 pacientes com Girdlestone unilateral e 3 com Girdlestone em um quadril e prótese total no quadril contralateral. A avaliação constitui-se em aplicar o questionário genérico de qualidade de vida SF-36 e um questionário funcional específico para o quadril, Harris Hip Score (HHS). A comparação dos grupos foi realizada usando-se o teste t- Student e o teste de Fisher. RESULTADOS: Os pacientes do grupo Girdlestone unilateral apresentaram maior quantidade de domínios do SF-36 classificados como elevados, embora 77,8% destes tenham obtido resultados ruins no HHS. Todos os pacientes apresentaram o teste de Trendelenburg positivo e discrepância de membros, o que levou à marcha claudicante em 11 dos 12 pacientes avaliados. Destes, apenas 6 submeteram-se a fisioterapia pós-operatória. CONCLUSÃO: A qualidade de vida e a função pós-operatória de Girdlestone, na população brasileira, ainda necessita ser mais pesquisada, pois estes resultados são indicações do comportamento das variáveis de estudo e não podem ser consideradas encerradas.Universidade Federal de São Paulo (UNIFESP) Escola Paulista de Medicina Departamento de Ortopedia e TraumatologiaUNIFESP-EPM DOTUNIFESP, EPM, Depto. de Ortopedia e TraumatologiaUNIFESP, EPM DOTSciEL
Abordagem cirurgica lateral do quadril com osteotomia parcial do trocanter maior
BV UNIFESP: Teses e dissertaçõe
OSTEOSYNTHESIS OF FEMORAL NECK FRACTURES: TWO OR THREE SCREWS?
ABSTRACTObjectives: To evaluate the efficacy of osteosynthesis on femoral neck fractures using two instead of three screws. Methods: Thirty-nine fractures were retrospectively evaluated, divided into groups in which two screws were used in parallel (n = 28) or three screws (n =11) in an inverted triangle configuration (in accordance with the AO technique). The patients were then followed up until reaching the outcome of either consolidation or failure. Results: In the group in which two screws were used, consolidation was observed in 23 of the 28 fractures (82%). In the group in which three screws were used, consolidation was observed in 6 of the 11 fractures (55%). There was no statistically significant difference between these percentages. Conclusion: There was no difference in the prognosis for these fractures when treated using two screws in parallel or three screws in an inverted triangle in accordance with the AO technique. Further studies are needed in order to establish a definitive conclusion
EVALUATION OF THE RANGE OF MOTION OF A HIP ARTHROPLASTY SYSTEM: A COMPUTER SIMULATION STUDY
ABSTRACT Objective: To date, the literature lacks consensus on the most efficient method to measure the range of motion of an in vitro prosthetic system. In this study, we propose the use of a relatively low-cost online software to measure the range of motion of hip prosthetic implants manufactured in Brazil and compare its results with the current technical standards for hip arthroplasty. Methods: Three different diameters of femoral heads were evaluated (28 mm, 32 mm, and 36 mm). The mean values of the angular displacement of the prosthesis in each motion axis were obtained by computer simulations. Results: The range of motion with each femoral head was 28mm (extension/flexion: 148°, internal/external rotation: 179°, adduction/abduction: 107°), 32 mm (152°/185°/114°), and 36 mm (158°/193°/120°). Conclusion: The computational method showed that the larger the femoral head, the greater the range of motion of the hip joint prosthetic system. Additional clinical studies are necessary to compare the physical results obtained with the values found in this study by computational modeling. Level of evidence V, Experimental study.</jats:p
Estudo biomecânico comparativo do desgaste do polietileno reticulado com cabeças femorais cerâmicas de 36 mm e com cabeças metálicas de 32 mm
Resumo
Objetivo: O objetivo do presente estudo foi comparar, in vitro, a taxa de desgaste do polietileno de alto peso molecular reticulado acoplado a cabeças cerâmicas de 36 mm de diâmetro e acoplado a cabeças metálicas de 32 mm de diâmetro.
Métodos: Foram realizados ensaios biomecânicos em simulador de desgaste para os pares tribológicos cerâmica-poli (36 mm) e metal-poli (32 mm) a fim de verificar a taxa de desgaste após em 15 × 106 ciclos.
Resultados: Na comparação entre as medidas de taxa de desgaste dos conjuntos com cabeças metálicas (média:14,12 mg/MC) e cerâmicas (média:7,46 mg/MC) houve diferença estatitsticamente significativa (p = 0,0005).
Conclusão: O presente estudo demonstrou menor taxa de desgaste em conjuntos protéticos que utilizaram o par tribológico cerâmica-polietileno reticulado de 36 mm em comparação aos conjuntos com metal-polietileno reticulado de 32 mm. Tal achado demonstra a eficácia do par tribológico cerâmica-poli, mesmo com a utilização de cabeças de grande diâmetro.</jats:p
