66 research outputs found

    Nanooptomechanical Transduction in a Single Crystal with 100% Photoconversion.

    Get PDF
    Materials that exhibit nanooptomechanical transduction in their single-crystal form have prospective use in light-driven molecular machinery, nanotechnology, and quantum computing. Linkage photoisomerization is typically the source of such transduction in coordination complexes, although the isomers tend to undergo only partial photoconversion. We present a nanooptomechanical transducer, trans-[Ru(SO2)(NH3)4(3-bromopyridine)]tosylate2, whose S-bound η1-SO2 isomer fully converts into an O-bound η1-OSO photoisomer that is metastable while kept at 100 K. Its 100% photoconversion is confirmed structurally via photocrystallography, while single-crystal optical absorption and Raman spectroscopies reveal its metal-to-ligand charge-transfer and temperature-dependent characteristics. This perfect optical switching affords the material good prospects for nanooptomechanical transduction with single-photon control

    Investigating the retention of intermediate-mass black holes in star clusters using N-body simulations

    Get PDF
    Contrary to supermassive and stellar-mass black holes (SBHs), the existence of intermediate-mass black holes (IMBHs) with masses ranging between 10^{2-5} Msun has not yet been confirmed. The main problem in the detection is that the innermost stellar kinematics of globular clusters (GCs) or small galaxies, the possible natural loci to IMBHs, are very difficult to resolve. However, if IMBHs reside in the centre of GCs, a possibility is that they interact dynamically with their environment. A binary formed with the IMBH and a compact object of the GC would naturally lead to a prominent source of gravitational radiation, detectable with future observatories. We use N-body simulations to study the evolution of GCs containing an IMBH and calculate the gravitational radiation emitted from dynamically formed IMBH-SBH binaries and the possibility that the IMBH escapes the GC after an IMBH-SBH merger. We run for the first time direct-summation integrations of GCs with an IMBH including the dynamical evolution of the IMBH with the stellar system and relativistic effects, such as energy loss in gravitational waves (GWs) and periapsis shift, and gravitational recoil. We find in one of our models an intermediate mass-ratio inspiral (IMRI), which leads to a merger with a recoiling velocity higher than the escape velocity of the GC. The GWs emitted fall in the range of frequencies that a LISA-like observatory could detect, like the European eLISA or in mission options considered in the recent preliminary mission study conducted in China. The merger has an impact on the global dynamics of the cluster, as an important heating source is removed when the merged system leaves the GC. The detection of one IMRI would constitute a test of GR, as well as an irrefutable proof of the existence of IMBHs.Comment: Accepted for publication by A&A, minor modification

    Ultrafast Pulse Radiolysis Using a Terawatt Laser Wakefield Accelerator

    Get PDF
    We report the first ultrafast pulse radiolysis transient absorption spectroscopy measurements from the Terawatt Ultrafast High Field Facility (TUHFF) at Argonne National Laboratory. TUHFF houses a 20 TW Ti:sapphire laser system that generates 2.5 nC sub-picosecond pulses of multi-MeV electrons at 10 Hz using laser wakefield acceleration. The system has been specifically optimized for kinetic measurements in a pump-probe fashion. This requires averaging over many shots which necessitates stable, reliable generation of electron pulses. The latter were used to generate excess electrons in pulse radiolysis of liquid water and concentrated solutions of perchloric acid. The hydronium ions in the acidic solutions react with the hydrated electrons resulting in the rapid decay of the transient absorbance at 800 nm on the picosecond time scale. Time resolution of a few picoseconds has been demonstrated. The current time resolution is determined primarily by the physical dimensions of the sample and the detection sensitivity. Subpicosecond time resolution can be achieved by using thinner samples, more sensitive detection techniques and improved electron beam quality.Comment: submitted to J. Appl. Phys. 5 figures, 23 page

    Enhancement of Local Piezoresponse in Polymer Ferroelectrics via Nanoscale Control of Microstructure

    Get PDF
    Polymer ferroelectrics are flexible and lightweight electromechanical materials that are widely studied due to their potential application as sensors, actuators, and energy harvesters. However, one of the biggest challenges is their low piezoelectric coefficient. Here, we report a mechanical annealing effect based on local pressure induced by a nanoscale tip that enhances the local piezoresponse. This process can control the nanoscale material properties over a microscale area at room temperature. We attribute this improvement to the formation and growth of β-phase extended chain crystals via sliding diffusion and crystal alignment along the scan axis under high mechanical stress. We believe that this technique can be useful for local enhancement of piezoresponse in ferroelectric polymer thin films
    • …
    corecore