311 research outputs found
Expert nurses' perceptions of the relevance of Carper's patterns of knowing to junior nurses.
This study explored with expert nurses in the UK how nursing wisdom can be developed in new and junior nurses. Carper's patterns of knowing and Benner's novice-to-expert continuum formed the theoretical framework. Employing a constructionist research methodology with participant engagement in co-construction of findings, data were collected via two separate cycles comprising four consecutive sessions followed by a nationally-advertised mini-conference. Empirical, ethical, personal, and aesthetic knowing were considered evident in junior nurses. Junior nurses in the UK seem to lack a previously-unrecognized domain of organizational knowing without which they cannot overcome hegemonic barriers to the successful development of nursing praxis
Risk perception of air pollution: A systematic review focused on particulate matter exposure
The adverse health effects of exposure to air pollutants, notably to particulate matter (PM), are well-known, as well as the association with measured or estimated concentration levels. The role of perception can be relevant in exploring effects and pollution control actions. The purpose of this study was to explore studies that analyse people’s perception, together with the measurement of air pollution, in order to elucidate the relationship between them. We conducted a systematic review in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. In March 2020, PubMed, EMBASE, and Scopus databases were explored in an attempt to search for studies published from 2000 to 2020. The review included 38 studies, most of which were conducted in China (n = 13) and the United States (n = 11) and published over the last four years (n = 26). Three studies were multicenter investigations, while five articles were based on a national-level survey. The air quality (AQ) was assessed by monitoring stations (n = 24) or dispersion models (n = 7). Many studies were population questionnaire-based, air monitoring and time-series studies, and web-based investigations. A direct association between exposure and perception emerged in 20 studies. This systematic review has shown that most of the studies establish a relationship between risk perception measurement. A broad spectrum of concepts and notions related to perception also emerged, which is undoubtedly an indicator of the wealth of available knowledge and is promising for future research
Recommended from our members
Roadmap to NRC Approval of Ceramic Matrix Composites in Generation IV Reactors
This report provides an initial roadmap to obtain Nuclear Regulatory Commission (NRC) approval for using these material systems in a nuclear application. The possible paths taken to achieving NRC approval are necessarily subject to change as this is an on-going process that shifts as more data and a clearer understanding of the nuclear regulations are gathered
Direction distributions of neutrons and reference values of the personal dose equivalent in workplace fields
Within the EC project EVIDOS, double-differential (energy and direction) fluence spectra were determined by means of novel direction spectrometers. By folding the spectra with fluence-to-dose equivalent conversion coefficients, contributions to H*(10) for 14 directions, and values of the personal dose equivalent Hp(10) and the effective dose E for 6 directions of a person's orientation in the field were determined. The results of the measurements and calculations obtained within the EVIDOS project in workplace fields in nuclear installations in Europe, i.e., at Krümmel (boiling water reactor and transport cask), at Mol (Venus research reactor and fuel facility Belgonucléaire) and at Ringhals (pressurised reactor and transport cask) are presente
Characterisation of mixed neutron-photon workplace fields at nuclear facilities by spectrometry (energy and direction) within the EVIDOS project
Within the EC project EVIDOS, 17 different mixed neutron-photon workplace fields at nuclear facilities (boiling water reactor, pressurised water reactor, research reactor, fuel processing, storage of spent fuel) were characterised using conventional Bonner sphere spectrometry and newly developed direction spectrometers. The results of the analysis, using Bayesian parameter estimation methods and different unfolding codes, some of them especially adapted to simultaneously unfold energy and direction distributions of the neutron fluence, showed that neutron spectra differed strongly at the different places, both in energy and direction distribution. The implication of the results for the determination of reference values for radiation protection quantities (ambient dose equivalent, personal dose equivalent and effective dose) and the related uncertainties are discusse
Evaluation of individual dosimetry in mixed neutron and photon radiation fields (EVIDOS). Part II: conclusions and recommendations
The paper presents the main conclusions and recommendations derived from the EVIDOS project, which is supported by the European Commission within the 5th Framework Programme. EVIDOS aims at evaluating state of the art neutron dosimetry techniques in representative workplaces of the nuclear industry with complex mixed neutron-photon radiation fields. This analysis complements a series of individual papers which present detailed results and it summarises the main findings from a practical point of view. Conclusions and recommendations are given concerning characterisation of radiation fields, methods to derive radiation protection quantities and dosemeter result
Neutron area survey instrument measurements in the EVIDOS project
Neutron survey instruments have been exposed at all the measurement locations used in the EVIDOS project. These results have an important impact in the interpretation of the results from the project, since operationally the survey instrument will be used for an initial assessment of and routine monitoring of the ambient dose equivalent dose rate. Additionally, since the response of these instruments is in some cases very well characterised, their systematic deviations from the reference quantities provide an important verification of the determination of those quantitie
Achievements in workplace neutron dosimetry in the last decade: lessons learned from the EVIDOS project
The availability of active neutron personal dosemeters has made real time monitoring of neutron doses possible. This has obvious benefits, but is only of any real assistance if the dose assessments made are of sufficient accuracy and reliability. Preliminary assessments of the performance of active neutron dosemeters can be made in calibration facilities, but these can never replicate the conditions under which the dosemeter is used in the workplace. Consequently, it is necessary to assess their performance in the workplace, which requires the field in the workplace to be fully characterised in terms of the energy and direction dependence of the fluence. This paper presents an overview of developments in workplace neutron dosimetry but concentrates on the outcomes of the EVIDOS project, which has made significant advances in the characterisation of workplace fields and the analysis of dosemeter responses in those field
Evaluation of individual dosimetry in mixed neutron and photon radiation fields (EVIDOS). Part I: scope and methods of the project
Supported by the European Commission, the EVIDOS project started in November 2001 with the broad goal of evaluating state of the art dosimetry techniques in representative workplaces of the nuclear industry. Seven European institutes joined efforts with end users at nuclear power plants, at fuel processing and reprocessing plants, and at transport and storage facilities. A comprehensive programme was devised to evaluate capabilities and limitations of standard and innovative personal dosemeters in relation to the mixed neutron-photon fields of concern to the nuclear industry. This paper describes the criteria behind the selection of dosimetry techniques and workplaces that were analysed, as well as the organisation of the measurement campaigns. Particular emphasis was placed on the evaluation of a variety of electronic personal dosemeters, either commercially available or previously developed by the partners. The estimates provided by these personal dosemeters were compared to reference values of dose equivalent quantities derived from spectrometry and fluence-to-dose equivalent conversion coefficients. Spectrometry was performed both with conventional multisphere and with some original instrumentation providing energy and direction resolution, based on silicon detectors and superheated drop detectors mounted on or in spherical moderators. The results were collected in a large, searchable database and are intended to be used in the harmonisation of dosimetric procedures for mixed radiation fields and for the approval of dosimetry services in Europ
Application of workplace correction factors to dosemeter results for the assessment of personal doses at nuclear facilities
Ratios of Hp(10) and H*(10) were determined with reference instruments in a number of workplace fields within the nuclear industry and used to derive workplace-specific correction factors. When commercial survey meter results together with these factors were applied to the results of the locally used personal dosemeters their results improved and became within 0.7 and 1.7 of the reference values or better depending on the response of the survey meter. A similar result was obtained when a correction was determined with a prototype reference instrument for Hp(10) after adjustment of its response. Commercially available survey instruments both for photon and neutron H*(10) measurements agreed with the reference instruments in most cases to within 0.5-1.5. Those conclusions are derived from results reported within the EC supported EVIDOS contrac
- …