952 research outputs found

    Frequency-Dependent Squeeze Amplitude Attenuation and Squeeze Angle Rotation by Electromagnetically Induced Transparency for Gravitational Wave Interferometers

    Full text link
    We study the effects of frequency-dependent squeeze amplitude attenuation and squeeze angle rotation by electromagnetically induced transparency (EIT) on gravitational wave (GW) interferometers. We propose the use of low-pass, band-pass, and high-pass EIT filters, an S-shaped EIT filter, and an intra-cavity EIT filter to generate frequency-dependent squeezing for injection into the antisymmetric port of GW interferometers. We find that the EIT filters have several advantages over the previous filter designs with regard to optical losses, compactness, and the tunability of the filter linewidth.Comment: 4 page

    An all-optical trap for a gram-scale mirror

    Get PDF
    We report on a stable optical trap suitable for a macroscopic mirror, wherein the dynamics of the mirror are fully dominated by radiation pressure. The technique employs two frequency-offset laser fields to simultaneously create a stiff optical restoring force and a viscous optical damping force. We show how these forces may be used to optically trap a free mass without introducing thermal noise; and we demonstrate the technique experimentally with a 1 gram mirror. The observed optical spring has an inferred Young's modulus of 1.2 TPa, 20% stiffer than diamond. The trap is intrinsically cold and reaches an effective temperature of 0.8 K, limited by technical noise in our apparatus.Comment: Major revision. Replacement is version that appears in Phy. Rev. Lett. 98, 150802 (2007

    Achieving ground state and enhancing entanglement by recovering information

    Get PDF
    For cavity-assisted optomechanical cooling experiments, it has been shown in the literature that the cavity bandwidth needs to be smaller than the mechanical frequency in order to achieve the quantum ground state of the mechanical oscillator, which is the so-called resolved-sideband or good-cavity limit. We provide a new but physically equivalent insight into the origin of such a limit: that is information loss due to a finite cavity bandwidth. With an optimal feedback control to recover those information, we can surpass the resolved-sideband limit and achieve the quantum ground state. Interestingly, recovering those information can also significantly enhance the optomechanical entanglement. Especially when the environmental temperature is high, the entanglement will either exist or vanish critically depending on whether information is recovered or not, which is a vivid example of a quantum eraser.Comment: 9 figures, 18 page

    A squeezed state source using radiation pressure induced rigidity

    Get PDF
    We propose an experiment to extract ponderomotive squeezing from an interferometer with high circulating power and low mass mirrors. In this interferometer, optical resonances of the arm cavities are detuned from the laser frequency, creating a mechanical rigidity that dramatically suppresses displacement noise. After taking into account imperfection of optical elements, laser noise, and other technical noise consistent with existing laser and optical technologies and typical laboratory environments, we expect the output light from the interferometer to have measurable squeezing of ~5 dB, with a frequency-independent squeeze angle for frequencies below 1 kHz. This squeeze source is well suited for injection into a gravitational-wave interferometer, leading to improved sensitivity from reduction in the quantum noise. Furthermore, this design provides an experimental test of quantum-limited radiation pressure effects, which have not previously been tested.Comment: 15 pages, 6 figures, submitted to Phys. Rev.

    The impact of acute surgical unit rostering on National Emergency Access Targets during the COVID-19 pandemic: a single hospital experience

    Get PDF
    Background: Surgical departments have been dramatically impacted by the novel coronavirus 19 (COVID-19) pandemic, with the cancellation of elective cases and changes to the provision of emergency surgical care. The aim of this study was to determine whether structural changes made within our facility's surgical department during COVID-19 altered National Emergency Access Target (NEAT) times and impacted on patient outcomes. Methods: Emergency surgical cases over a 4-month time period were retrospectively collected and statistically analysed, divided into pre- and mid-COVID-19 pandemic. Results: Baseline characteristics between the groups were comparable. There was a significant increase in consultant presence in theatre in the COVID group. There were also statistically significant reductions in NEAT times at each timepoint, although these did not meet national guidelines. There was no change in emergency surgical workload, complication rate or mortality rates within 30 days. Conclusion: Any significant change to services requires a coordinated hospital-wide approach, not just from a single department, and clinicians must continue to be wary of benchmarked times as the overall feasibility and safety of NEAT times has also been highlighted again

    E-readiness to G-readiness: developing a green information technology readiness framework

    Get PDF
    Businesses are under increasing pressure from competitors, regulators and community groups to implement sustainable business practices. Balancing economic and environmental performance to be green and competitive is therefore a key strategic issue. The increased discussion on green information technology (IT) has sparked the interest of this research. Green IT is poised to influence not only technology but also competitive strategy and even the legality of some business strategic options. Understanding and leveraging Green IT is therefore critical for businesses¿ continued progress. Nevertheless, the principles, practices and value of Green IT is yet to be researched. This paper introduces the concept of Green IT and describes the main pillars of a g-readiness framework to help organisations evaluate their readiness for adopting Green IT. It argues that just as e-readiness has been, and continues to be, a critical quality in the digital economy, g-readiness is an equally critical quality in the low carbon digital economy. Without a clear understanding of g-readiness, organisations would approach Green IT initiatives on an ad hoc and somewhat reactive basis which is undesirable

    A microchip optomechanical accelerometer

    Get PDF
    The monitoring of accelerations is essential for a variety of applications ranging from inertial navigation to consumer electronics. The basic operation principle of an accelerometer is to measure the displacement of a flexibly mounted test mass; sensitive displacement measurement can be realized using capacitive, piezo-electric, tunnel-current, or optical methods. While optical readout provides superior displacement resolution and resilience to electromagnetic interference, current optical accelerometers either do not allow for chip-scale integration or require bulky test masses. Here we demonstrate an optomechanical accelerometer that employs ultra-sensitive all-optical displacement read-out using a planar photonic crystal cavity monolithically integrated with a nano-tethered test mass of high mechanical Q-factor. This device architecture allows for full on-chip integration and achieves a broadband acceleration resolution of 10 \mu g/rt-Hz, a bandwidth greater than 20 kHz, and a dynamic range of 50 dB with sub-milliwatt optical power requirements. Moreover, the nano-gram test masses used here allow for optomechanical back-action in the form of cooling or the optical spring effect, setting the stage for a new class of motional sensors.Comment: 16 pages, 9 figure

    Quantum Measurement Theory in Gravitational-Wave Detectors

    Get PDF
    The fast progress in improving the sensitivity of the gravitational-wave (GW) detectors, we all have witnessed in the recent years, has propelled the scientific community to the point, when quantum behaviour of such immense measurement devices as kilometer-long interferometers starts to matter. The time, when their sensitivity will be mainly limited by the quantum noise of light is round the corner, and finding the ways to reduce it will become a necessity. Therefore, the primary goal we pursued in this review was to familiarize a broad spectrum of readers with the theory of quantum measurements in the very form it finds application in the area of gravitational-wave detection. We focus on how quantum noise arises in gravitational-wave interferometers and what limitations it imposes on the achievable sensitivity. We start from the very basic concepts and gradually advance to the general linear quantum measurement theory and its application to the calculation of quantum noise in the contemporary and planned interferometric detectors of gravitational radiation of the first and second generation. Special attention is paid to the concept of Standard Quantum Limit and the methods of its surmounting.Comment: 147 pages, 46 figures, 1 table. Published in Living Reviews in Relativit

    Resolved Sideband Cooling of a Micromechanical Oscillator

    Full text link
    Micro- and nanoscale opto-mechanical systems provide radiation pressure coupling of optical and mechanical degree of freedom and are actively pursued for their ability to explore quantum mechanical phenomena of macroscopic objects. Many of these investigations require preparation of the mechanical system in or close to its quantum ground state. Remarkable progress in ground state cooling has been achieved for trapped ions and atoms confined in optical lattices. Imperative to this progress has been the technique of resolved sideband cooling, which allows overcoming the inherent temperature limit of Doppler cooling and necessitates a harmonic trapping frequency which exceeds the atomic species' transition rate. The recent advent of cavity back-action cooling of mechanical oscillators by radiation pressure has followed a similar path with Doppler-type cooling being demonstrated, but lacking inherently the ability to attain ground state cooling as recently predicted. Here we demonstrate for the first time resolved sideband cooling of a mechanical oscillator. By pumping the first lower sideband of an optical microcavity, whose decay rate is more than twenty times smaller than the eigen-frequency of the associated mechanical oscillator, cooling rates above 1.5 MHz are attained. Direct spectroscopy of the motional sidebands reveals 40-fold suppression of motional increasing processes, which could enable reaching phonon occupancies well below unity (<0.03). Elemental demonstration of resolved sideband cooling as reported here should find widespread use in opto-mechanical cooling experiments. Apart from ground state cooling, this regime allows realization of motion measurement with an accuracy exceeding the standard quantum limit.Comment: 13 pages, 5 figure
    • …
    corecore