5 research outputs found

    First Measurements of a Prototype of a New Generation Pixel Readout ASIC in 65 nm CMOS for Extreme Rate HEP Detectors at HL-LHC

    Get PDF
    A first prototype of a readout ASIC in CMOS 65nm for a pixel detector at High Luminosity LHC is described. The pixel cell area is 50x50 um2 and the matrix consists of 64x64 pixels. The chip was designed to guarantee high efficiency at extreme data rates for very low signals and with low power consumption. Two different analogue front-end designs, one synchronous and one asynchronous, were implemented, both occupying an area of 35x35 um2. ENC value is below 100e- for an input capacitance of 50 fF and in-time threshold below 1000e-. Leakage current compensation up to 50 nA with power consumption below 5 uW. A ToT technique is used to perform charge digitization with 5-bit precision using either a 40 MHz clock or a local Fast Oscillator up to 800 MHz. Internal 10-bit DAC's are used for biasing, while monitoring is provided by a 12-bit ADC. A novel digital architecture has been developed to ensure above 99.5% hit efficiency at pixel hit rates up to 3 GHz/cm2, trigger rates up to 1 MHz and trigger latency of 12.5 us. The total power consumption per pixel is below 5uW. Analogue dead-time is below 1%. Data are sent via a serializer connected to a CMOS-to-SLVS transmitter working at 320 MHz. All IP-blocks and front-ends used are silicon-proven and tested after exposure to ionizing radiation levels of 500-800 Mrad. The chip was designed as part of the Italian INFN CHIPIX65 project and in close synergy with the international CERN RD53 and was submitted in July 2016 for production. Early test results for both front-ends regarding minimum threshold, auto-zeroing and low-noise performance are high encouraging and will be presented in this paper

    BASIC32: A New ASIC for Silicon Photomultiplier Detectors

    No full text
    Silicon Photomultipliers (SiPM) have shown to be excellent substitutes for more traditional and bulky Photomultiplier Tubes (PMT) in many photon detection applications, thanks essentially to their high quantum efficiency, lowbias voltage and immunity to magnetic fields.However, they pose some challenging design constraints on the design of the electronic front-end (FE) due to their intrinsic high gain and speed. In particular, when changing from low to high light levels of exposition, they produce output signals whose amplitude may span over about three order of magnitude with rise times of less than 1 ns. This is of particular concern when developing integrated multichannel electronics in deep submicron technology. We report here on the realization of a 32-channel ASIC in CMOS technology, based on an innovative current-mode architecture. Besides presenting the experimental results of the ASIC characterization, some perspective indications are given concerning the work currently in progress

    Development of a Large Pixel Chip Demonstrator in RD53 for ATLAS and CMS Upgrades

    No full text
    RD53A is a large scale 65 nm CMOS pixel demonstrator chip that has been developed by the RD53 collaboration for very high rate (3 GHz/cm2) and very high radiation levels (500 Mrad, possibly 1 Grad) for ATLAS and CMS phase 2 upgrades. It features serial powering operation and design variations in the analog and digital pixel matrix for different testing purposes. The design and verification of RD53A are described together with an outline of the plans to develop final pixel chips for the two experiments

    Practice of proctology among general surgery residents and young specialists in Italy: a snapshot survey

    No full text
    Anal diseases are very common and, in most of the cases, require surgery of minor or medium complexity, and, therefore, are among the most accessible diseases for surgeons in training. Aim of this study is to investigate the status of the training in proctology in Italy. A 31-items questionnaire was administered to residents and young specialists (<= 2 years) in general surgery, using mailing lists, and the social media accounts of the Italian Society of Colorectal Surgery. Answers from 338 respondents (53.8% males) were included in the final analysis. Overall, 252 respondents (74.5%) were residents and 86 (25.5%) young specialists. Two hundred and fifty-five (75.4%) respondents practiced proctology for the first time early on during their postgraduate training, but only 19.5% did it continuously for >= 24 months. Almost all respondents (334; 98.8%) had the chance to participate in proctological procedures, 205 (60.5%) as first surgeon. This percentage decreases according to the complexity of the surgery. In fact, only 11 (3.3%) and 24 (7.1%) of the respondents were allowed to be the first surgeon in more complex proctological diseases such as surgery for rectal prolapse and fecal incontinence. The present survey suggests that, in Italy, most surgeons in training deal with anal diseases. However, only few of them could achieve sufficient professional skills in the management of proctological diseases to be able to practice autonomously as young specialists

    Impact of COVID-19 infection on lung function and nutritional status amongst individuals with cystic fibrosis: A global cohort study

    No full text
    International audienceBackground: Factors associated with severe COVID-19 infection have been identified; however, the impact of infection on longer-term outcomes is unclear. The objective of this study was to examine the impact of COVID-19 infection on the trajectory of lung function and nutritional status in people with cystic fibrosis (pwCF).Methods: This is a retrospective global cohort study of pwCF who had confirmed COVID-19 infection diagnosed between January 1, 2020 and December 31, 2021. Forced expiratory volume in one second percent predicted (ppFEV 1 ) and body mass index (BMI) twelve months prior to and following a diagnosis of COVID-19 were recorded. Change in mean ppFEV 1 and BMI were compared using a t-test. A linear mixed-effects model was used to estimate change over time and to compare the rate of change before and after infection.Results: A total of 6,500 cases of COVID-19 in pwCF from 33 countries were included for analysis. The mean difference in ppFEV 1 pre-and post-infection was 1.4 %, (95 % CI 1.1, 1.7). In those not on modulators, the difference in rate of change pre-and post-infection was 1.34 %, (95 % CI -0.88, 3.56) per year (p = 0.24) and -0.74 % (-1.89, 0.41) per year (p = 0.21) for those on elexacaftor/tezacaftor/ivacaftor. No clinically significant change was noted in BMI or BMI percentile before and after COVID-19 infection.Conclusions: No clinically meaningful impact on lung function and BMI trajectory in the year following infection with COVID-19 was identified. This work highlights the ability of the global CF community to unify and address critical issues facing pwCF
    corecore