99 research outputs found

    Simultaneous self-supervised reconstruction and denoising of sub-sampled MRI data with Noisier2Noise

    Full text link
    Most existing methods for Magnetic Resonance Imaging (MRI) reconstruction with deep learning assume that a high signal-to-noise ratio (SNR), fully sampled sampled dataset exists and use fully supervised training. In many circumstances, however, such a dataset does not exist and may be highly impractical to acquire. Recently, a number of self-supervised methods for MR reconstruction have been proposed, which require a training dataset with sub-sampled k-space data only. However, existing methods do not denoise sampled data, so are only applicable in the high SNR regime. In this work, we propose a method based on Noisier2Noise and Self-Supervised Learning via Data Undersampling (SSDU) that trains a network to reconstruct clean images from sub-sampled, noisy training data. To our knowledge, our approach is the first that simultaneously denoises and reconstructs images in an entirely self-supervised manner. Our method is applicable to any network architecture, has a strong mathematical basis, and is straight-forward to implement. We evaluate our method on the multi-coil fastMRI brain dataset and find that it performs competitively with a network trained on clean, fully sampled data and substantially improves over methods that do not explicitly remove measurement noise.Comment: Submitted to IEEE International Symposium on Biomedical Imaging (ISBI) 202

    PEAR: PEriodic And fixed Rank separation for fast fMRI

    Full text link
    In functional MRI (fMRI), faster acquisition via undersampling of data can improve the spatial-temporal resolution trade-off and increase statistical robustness through increased degrees-of-freedom. High quality reconstruction of fMRI data from undersampled measurements requires proper modeling of the data. We present an fMRI reconstruction approach based on modeling the fMRI signal as a sum of periodic and fixed rank components, for improved reconstruction from undersampled measurements. We decompose the fMRI signal into a component which a has fixed rank and a component consisting of a sum of periodic signals which is sparse in the temporal Fourier domain. Data reconstruction is performed by solving a constrained problem that enforces a fixed, moderate rank on one of the components, and a limited number of temporal frequencies on the other. Our approach is coined PEAR - PEriodic And fixed Rank separation for fast fMRI. Experimental results include purely synthetic simulation, a simulation with real timecourses and retrospective undersampling of a real fMRI dataset. Evaluation was performed both quantitatively and visually versus ground truth, comparing PEAR to two additional recent methods for fMRI reconstruction from undersampled measurements. Results demonstrate PEAR's improvement in estimating the timecourses and activation maps versus the methods compared against at acceleration ratios of R=8,16 (for simulated data) and R=6.66,10 (for real data). PEAR results in reconstruction with higher fidelity than when using a fixed-rank based model or a conventional Low-rank+Sparse algorithm. We have shown that splitting the functional information between the components leads to better modeling of fMRI, over state-of-the-art methods

    Combined angiographic, structural and perfusion radial imaging using arterial spin labeling

    Get PDF
    A Combined Angiographic, Structural and Perfusion Radial Imaging using Arterial Spin Labeling (CASPRIA) pulse sequence is presented which allows the simultaneous acquisition of non-contrast dynamic angiograms, quantitative perfusion maps and multi-contrast T1-weighted structural images within a single six-minute scan. Compared to conventional imaging methods, which took 70% longer to acquire, CASPRIA yielded comparable quantitative perfusion estimates, dynamic (rather than static) angiography with improved distal vessel visibility and structural images with greater contrast flexibility. With further work, the estimation of quantitative tissue T1 values could also be possible

    Adapting water management to climate change in the Murray–Darling Basin, Australia

    Get PDF
    Climate change is threatening water security in water-scarce regions across the world, challenging water management policy in terms of how best to adapt. Transformative new approaches have been proposed, but management policies remain largely the same in many instances, and there are claims that good current management practice is well adapted. This paper takes the case of the Murray–Darling Basin, Australia, where management policies are highly sophisticated and have been through a recent transformation in order to critically review how well adapted the basin’s management is to climate change. This paper synthesizes published data, recent literature, and water plans in order to evaluate the outcomes of water management policy. It identifies several limitations and inequities that could emerge in the context of climate change and, through synthesis of the broader climate adaptation literature, proposes solutions that can be implemented when basin management is formally reviewed in 2026

    Self-navigated 3D diffusion MRI using an optimized CAIPI sampling and structured low-rank reconstruction estimated navigator

    Get PDF
    3D multi-slab acquisitions are an appealing approach for diffusion MRI because they are compatible with the imaging regime delivering optimal SNR efficiency. In conventional 3D multi-slab imaging, shot-to-shot phase variations caused by motion pose challenges due to the use of multi-shot k-space acquisition. Navigator acquisition after each imaging echo is typically employed to correct phase variations, which prolongs scan time and increases the specific absorption rate (SAR). The aim of this study is to develop a highly efficient, self-navigated method to correct for phase variations in 3D multi-slab diffusion MRI without explicitly acquiring navigators. The sampling of each shot is carefully designed to intersect with the central kz=0 plane of each slab, and the multi-shot sampling is optimized for self-navigation performance while retaining decent reconstruction quality. The kz=0 intersections from all shots are jointly used to reconstruct a 2D phase map for each shot using a structured low-rank constrained reconstruction that leverages the redundancy in shot and coil dimensions. The phase maps are used to eliminate the shot-to-shot phase inconsistency in the final 3D multi-shot reconstruction. We demonstrate the method’s efficacy using retrospective simulations and prospectively acquired in-vivo experiments at 1.22 mm and 1.09 mm isotropic resolutions. Compared to conventional navigated 3D multislab imaging, the proposed self-navigated method achieves comparable image quality while shortening the scan time by 31.7% and improving the SNR efficiency by 15.5%. The proposed method produces comparable quality of DTI and white matter tractography to conventional navigated 3D multi-slab acquisition with a much shorter scan time

    Dynamic off-resonance correction improves functional image analysis in fMRI of awake behaving non-human primates

    Get PDF
    Introduction: Use of functional MRI in awake non-human primate (NHPs) has recently increased. Scanning animals while awake makes data collection possible in the absence of anesthetic modulation and with an extended range of possible experimental designs. Robust awake NHP imaging however is challenging due to the strong artifacts caused by time-varying off-resonance changes introduced by the animal's body motion. In this study, we sought to thoroughly investigate the effect of a newly proposed dynamic off-resonance correction method on brain activation estimates using extended awake NHP data. Methods: We correct for dynamic B0 changes in reconstruction of highly accelerated simultaneous multi-slice EPI acquisitions by estimating and correcting for dynamic field perturbations. Functional MRI data were collected in four male rhesus monkeys performing a decision-making task in the scanner, and analyses of improvements in sensitivity and reliability were performed compared to conventional image reconstruction. Results: Applying the correction resulted in reduced bias and improved temporal stability in the reconstructed time-series data. We found increased sensitivity to functional activation at the individual and group levels, as well as improved reliability of statistical parameter estimates. Conclusions: Our results show significant improvements in image fidelity using our proposed correction strategy, as well as greatly enhanced and more reliable activation estimates in GLM analyses

    Self-navigated 3D diffusion MRI using an optimized CAIPI sampling and structured low-rank reconstruction

    Full text link
    3D multi-slab acquisitions are an appealing approach for diffusion MRI because they are compatible with the imaging regime delivering optimal SNR efficiency. In conventional 3D multi-slab imaging, shot-to-shot phase variations caused by motion pose challenges due to the use of multi-shot k-space acquisition. Navigator acquisition after each imaging echo is typically employed to correct phase variations, which prolongs scan time and increases the specific absorption rate (SAR). The aim of this study is to develop a highly efficient, self-navigated method to correct for phase variations in 3D multi-slab diffusion MRI without explicitly acquiring navigators. The sampling of each shot is carefully designed to intersect with the central kz plane of each slab, and the multi-shot sampling is optimized for self-navigation performance while retaining decent reconstruction quality. The central kz intersections from all shots are jointly used to reconstruct a 2D phase map for each shot using a structured low-rank constrained reconstruction that leverages the redundancy in shot and coil dimensions. The phase maps are used to eliminate the shot-to-shot phase inconsistency in the final 3D multi-shot reconstruction. We demonstrate the method's efficacy using retrospective simulations and prospectively acquired in-vivo experiments at 1.22 mm and 1.09 mm isotropic resolutions. Compared to conventional navigated 3D multi-slab imaging, the proposed self-navigated method achieves comparable image quality while shortening the scan time by 31.7% and improving the SNR efficiency by 15.5%. The proposed method produces comparable quality of DTI and white matter tractography to conventional navigated 3D multi-slab acquisition with a much shorter scan time.Comment: 10 pages, 11 figures, 2 tables. This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessibl

    Efficient 3D cone trajectory design for improved combined angiographic and perfusion imaging using arterial spin labeling

    Get PDF
    Purpose To improve the spatial resolution and repeatability of a non-contrast MRI technique for simultaneous time resolved 3D angiography and perfusion imaging by developing an efficient 3D cone trajectory design. Methods A novel parameterized 3D cone trajectory design incorporating the 3D golden angle was integrated into 4D combined angiography and perfusion using radial imaging and arterial spin labeling (CAPRIA) to achieve higher spatial resolution and sampling efficiency for both dynamic angiography and perfusion imaging with flexible spatiotemporal resolution. Numerical simulations and physical phantom scanning were used to optimize the cone design. Eight healthy volunteers were scanned to compare the original radial trajectory in 4D CAPRIA with our newly designed cone trajectory. A locally low rank reconstruction method was used to leverage the complementary k-space sampling across time. Results The improved sampling in the periphery of k-space obtained with the optimized 3D cone trajectory resulted in improved spatial resolution compared with the radial trajectory in phantom scans. Improved vessel sharpness and perfusion visualization were also achieved in vivo. Less dephasing was observed in the angiograms because of the short TE of our cone trajectory and the improved k-space sampling efficiency also resulted in higher repeatability compared to the original radial approach. Conclusion The proposed 3D cone trajectory combined with 3D golden angle ordering resulted in improved spatial resolution and image quality for both angiography and perfusion imaging and could potentially benefit other applications that require an efficient sampling scheme with flexible spatial and temporal resolution

    Probabilistic optimization for conceptual rainfall-runoff models: a comparison of the shuffled complex evolution and simulated annealing algorithms

    Get PDF
    Automatic optimization algorithms are used routinely to calibrate conceptual rainfall-runoff (CRR) models. The goal of calibration is to estimate a feasible and unique (global) set of parameter estimates that best fit the observed runoff data. Most if not all optimization algorithms have difficulty in locating the global optimum because of response surfaces that contain multiple local optima with regions of attraction of differing size, discontinuities, and long ridges and valleys. Extensive research has been undertaken to develop efficient and robust global optimization algorithms over the last 10 years. This study compares the performance of two probabilistic global optimization methods: the shuffled complex evolution algorithm SCE-UA, and the three-phase simulated annealing algorithm SA-SX. Both algorithms are used to calibrate two parameter sets of a modified version of Boughtoh's [1984] SFB model using data from two Australian catchments that have low and high runoff yields. For the reduced, well-identified parameter set the algorithms have a similar efficiency for the low-yielding catchment, but SCE-UA is almost twice as robust. Although the robustness of the algorithms is similar for the high-yielding catchment, SCE-UA is six times more efficient than SA-SX. When fitting the full parameter set the performance of SA-SX deteriorated markedly for both catchments. These results indicated that SCE-UA's use of multiple complexes and shuffling provided a more effective search of the parameter space than SA-SX's single simplex with stochastic step acceptance criterion, especially when the level of parameterization is increased. Examination of the response surface for the low-yielding catchment revealed some reasons why SCE-UA outperformed SA-SX and why probabilistic optimization algorithms can experience difficulty in locating the global optimum.Mark Thyer and George Kuczera, Bryson C. Bate
    • …
    corecore